単元素分析の消耗品が見つかるアジレントの便利な周期表

標準物質

必要な標準物質と消耗品をお探しの場合は、表の元素をクリックしてください

  • アルカリ金属
  • アルカリ土類金属
  • 遷移金属
  • ランタノイド
  • アクチニド
  • ポスト遷移金属
  • 有機金属
  • 非金属
  • ハロゲン
  • 希ガス
  • アジレントから
    入手可能な単元素標準液(日本では販売していない場合があります)
  • アジレントで未販売
Group
1
IA
2
IIA
3
IIIB
4
IVB
5
VB
6
VIB
7
VIIB
8
9
VIII
10
11
IB
12
IIB
13
IIIA
14
IVA
15
VA
16
VIA
17
VIIA
18
VIIIA

1

H

1
Atomic number
1.008
Atomic weight
H
Element symbol
13.60
First ionization potential (eV)
-259
Melting point (°C)/1 atm

-253
Boiling point (°C)/1 atm

Hydrogen

Atomic weight: 1.008

Isotope abundance: 1 (99.99%); 2 (0.01%)

Oxidation states: +1, 0, -1

Hydrogen

2

He

2
Atomic number
4.003
Atomic weight
He
Element symbol
24.59
First ionization potential (eV)

54.42
Second ionization potential (eV)
-269
Melting point (°C)/1 atm

Helium

Atomic weight: 4.003

Isotope abundance: 4 (100%)

Oxidation states: 0

Helium

3

Li

3
Atomic number
6.94
Atomic weight
Li
Element symbol
5.39
First ionization potential (eV)

75.64
Second ionization potential (eV)
181
Melting point (°C)/1 atm

1342
Boiling point (°C)/1 atm

Lithium

Atomic weight: 6.941

Chemical form in solution: Li+(aq) (large effective radius due to hydration sphere)

Isotope abundance: 6 (7.59%); 7 (92.41%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8289 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8290 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-203 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8408 10,000 µg/mL 5% HNO3 100mL CRM
5190-8409 10,000 µg/mL 5% HNO3 500mL CRM
ICP-103 10,000 µg/mL 10% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8477 1,000 µg/mL 5% HNO3 100mL CRM
5190-8478 1,000 µg/mL 5% HNO3 500mL CRM
ICP-003 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8572 10 µg/mL 2% HNO3 100mL CRM
5190-8589 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610103000 Coded Lithium (Li) coded single element hollow cathode lamp
5610124900 Uncoded Lithium (Li) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Lithium

4

Be

4
Atomic number
9.012
Atomic weight
Be
Element symbol
9.32
First ionization potential (eV)

18.21
Second ionization potential (eV)
1287
Melting point (°C)/1 atm

2468
Boiling point (°C)/1 atm

Beryllium

Atomic weight: 9.012

Chemical form in solution: Be2+(H2O)42+

Isotope abundance: 9 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8264 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8265 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-204 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8360 10,000 µg/mL 5% HNO3 100mL CRM
5190-8361 10,000 µg/mL 5% HNO3 500mL CRM
ICP-104 10,000 µg/mL 5% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8250 1,000 µg/mL 5% HNO3 100mL CRM
5190-8251 1,000 µg/mL 5% HNO3 500mL CRM
ICP-004 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8565 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100500 Coded Beryllium (Be) coded single element hollow cathode lamp
5610122400 Uncoded Beryllium (Be) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Beryllium

5

B

5
Atomic number
10.81
Atomic weight
B
Element symbol
8.30
First ionization potential (eV)

25.15
Second ionization potential (eV)
2077
Melting point (°C)/1 atm

4000
Boiling point (°C)/1 atm

Boron

Atomic weight: 10.811

Chemical form in solution: B(OH)3 and B(OH)4-

Isotope abundance: 10 (19.9%); 11 (80.1%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-1,000 ppm solutions chemically stable for years in 1% HNO3/LDPE container. 1000-10,000 ppm stable for years in dilute NH4OH/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8268 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8269 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-205 1,000 µg/mL 2% NH4OH 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8364 10,000 µg/mL 1% NH4OH 100mL CRM
5190-8365 10,000 µg/mL 1% NH4OH 500mL CRM
ICP-105 10,000 µg/mL 2% NH4OH 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8254 1,000 µg/mL H2O 100mL CRM
5190-8255 1,000 µg/mL H2O 500mL CRM
ICP-005 1,000 µg/mL 2% NH4OH 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8566 10 µg/mL H2O 100mL CRM

Single element lamps

Part No. Type Description
5610100700 Coded Boron (B) coded single element hollow cathode lamp
5610122600 Uncoded Boron (B) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135700 High intensity UltrAA Boron (B) high intensity UltrAA coded single element hollow cathode lamp

Boron

6

C

6
Atomic number
12.01
Atomic weight
C
Element symbol
11.26
First ionization potential (eV)

24.38
Second ionization potential (eV)
3825
Melting point (°C)/1 atm

3825
Boiling point (°C)/1 atm

Carbon

Atomic weight: 12.011

Chemical form in solution: (Carbon standard is made using Tartaric Acid)

Isotope abundance: 12 (98.93%); 13 (1.07%)

Oxidation states: +4, +2, -4

Carbon

7

N

7
Atomic number
14.01
Atomic weight
N
Element symbol
14.53
First ionization potential (eV)

29.60
Second ionization potential (eV)
-210
Melting point (°C)/1 atm

-196
Boiling point (°C)/1 atm

Nitrogen

Atomic weight: 14.007

Isotope abundance: 14 (99.64%); 15 (0.36%)

Oxidation states: +5, +4, +3, +2, -1, -2, -3

Nitrogen

8

O

8
Atomic number
16.00
Atomic weight
O
Element symbol
13.62
First ionization potential (eV)

35.12
Second ionization potential (eV)
-219
Melting point (°C)/1 atm

-183
Boiling point (°C)/1 atm

Oxygen

Atomic weight: 15.999

Isotope abundance: 16 (99.76%); 17 (0.04%); 18 (0.2%)

Oxidation states: +2, +1, 0, -1, -2

Oxygen

9

F

9
Atomic number
19.00
Atomic weight
F
Element symbol
17.42
First ionization potential (eV)

34.97
Second ionization potential (eV)
-220
Melting point (°C)/1 atm

-188
Boiling point (°C)/1 atm

Fluorine

Atomic weight: 18.998

Isotope abundance: 19 (100%)

Oxidation states: -1

Fluorine

10

Ne

10
Atomic number
20.18
Atomic weight
Ne
Element symbol
21.56
First ionization potential (eV)

40.96
Second ionization potential (eV)
-249
Melting point (°C)/1 atm

-246
Boiling point (°C)/1 atm

Neon

Atomic weight: 20.179

Isotope abundance: 20 (90.48%); 21 (0.27%); 22 (9.25%)

Oxidation states: 0

Neon

11

Na

11
Atomic number
22.99
Atomic weight
Na
Element symbol
5.14
First ionization potential (eV)

47.29
Second ionization potential (eV)
98
Melting point (°C)/1 atm

883
Boiling point (°C)/1 atm

Sodium

Atomic weight: 22.98977

Chemical form in solution: Na+(H2O)n+

Isotope abundance: 23 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8311 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8312 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-211 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8454 10,000 µg/mL 5% HNO3 100mL CRM
5190-8206 10,000 µg/mL 5% HNO3 500mL CRM
ICP-111 10,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8525 1,000 µg/mL 5% HNO3 100mL CRM
5190-8526 1,000 µg/mL 5% HNO3 500mL CRM
ICP-011 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-411 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610105300 Coded Sodium (Na) coded single element hollow cathode lamp
5610127300 Uncoded Sodium (Na) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Sodium

12

Mg

12
Atomic number
24.31
Atomic weight
Mg
Element symbol
7.65
First ionization potential (eV)

15.04
Second ionization potential (eV)
650
Melting point (°C)/1 atm

1090
Boiling point (°C)/1 atm

Magnesium

Atomic Weight: 24.305

Chemical form in solution: Mg(H2O)6+2

Isotope abundance: 24 (78.99%)*; 25 (10%); 26 (11.01%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8291 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8292 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-212 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8412 10,000 µg/mL 5% HNO3 100mL CRM
5190-8413 10,000 µg/mL 5% HNO3 500mL CRM
ICP-112 10,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8481 1,000 µg/mL 5% HNO3 100mL CRM
5190-8482 1,000 µg/mL 5% HNO3 500mL CRM
ICP-012 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-412 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610103200 Coded Magnesium (Mg) coded single element hollow cathode lamp
5610125100 Uncoded Magnesium (Mg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Magnesium

13

Al

13
Atomic number
26.98
Atomic weight
Al
Element symbol
5.99
First ionization potential (eV)

18.83
Second ionization potential (eV)
660
Melting point (°C)/1 atm

2519
Boiling point (°C)/1 atm

Aluminum

Atomic Weight: 26.98154

Chemical form in solution: Al(H2O)6+3

Isotope abundance: 27 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8256 1,000 µg/mL 5% HCl 100 mL CRM
5190-8257 1,000 µg/mL 5% HCl 500 mL CRM
IAA-213 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8352 10,000 µg/mL 5% HNO3 100mL CRM
5190-8353 10,000 µg/mL 5% HNO3 500mL CRM
ICP-113 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8242 1,000 µg/mL 5% HNO3 100mL CRM
5190-8243 1,000 µg/mL 5% HNO3 500mL CRM
ICP-013 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8561 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100100 Coded Aluminum (Al) coded single element hollow cathode lamp
5610122000 Uncoded Aluminum (Al) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Aluminum

14

Si

14
Atomic number
28.09
Atomic weight
Si
Element symbol
8.15
First ionization potential (eV)

16.35
Second ionization potential (eV)
1414
Melting point (°C)/1 atm

3265
Boiling point (°C)/1 atm

Silicon

Atomic Weight: 28.0855

Chemical form in solution: Si(OH)x(F)y2-

Isotope abundance: 28 (92.22%)*; 29 (4.69%); 30 (3.09%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—(alone or mixed with all other metals) as the Si(OH)x(F)y2-. 1-10,000 ppm single element solutions as the Si(OH)x(F)y2- chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • H2O at pH 7
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8308 1,000 µg/mL H2O 100 mL CRM
IAA-214 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8450 10,000 µg/mL H2O 100mL CRM
5190-8451 10,000 µg/mL H2O 500mL CRM
ICP-114 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8521 1,000 µg/mL H2O 100mL CRM
5190-8522 1,000 µg/mL H2O 500mL CRM
ICP-014 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-414 10 µg/mL 0.5% HNO3 with 0.1% HF 125mL CRM

Single element lamps

Part No. Type Description
5610105100 Coded Silicon (Si) coded single element hollow cathode lamp
5610127100 Uncoded Silicon (Si) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133400 High intensity UltrAA Silicon (Si) high intensity UltrAA coded single element hollow cathode lamp

Silicon

15

P

15
Atomic number
30.97
Atomic weight
P
Element symbol
10.49
First ionization potential (eV)

19.77
Second ionization potential (eV)
44
Melting point (°C)/1 atm

281
Boiling point (°C)/1 atm

Phosphorus

Atomic weight: 30.97376

Chemical form in solution: OP(OH)2(O)-

Isotope abundance: 31 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, +2, +1, -2, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0-1% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-215 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8428 10,000 µg/mL 5% HNO3 100mL CRM
5190-8429 10,000 µg/mL 5% HNO3 500mL CRM
ICP-115 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8499 1,000 µg/mL 5% HNO3 100mL CRM
5190-8500 1,000 µg/mL 5% HNO3 500mL CRM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-415 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610107700 Coded Phosphorus (P) coded single element hollow cathode lamp
5610126000 Uncoded Phosphorus (P) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Phosphorus

16

S

16
Atomic number
32.06
Atomic weight
S
Element symbol
10.36
First ionization potential (eV)

23.34
Second ionization potential (eV)
115
Melting point (°C)/1 atm

445
Boiling point (°C)/1 atm

Sulfur

Atomic weight: 32.066

Chemical form in solution: (O)2S(OH)2

Isotope abundance: 32 (94.99%); 33 (0.75%); 34 (4.25%)*; 36 (0.01%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-216 1,000 µg/mL H2O 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8209 10,000 µg/mL H2O 100mL CRM
5190-8210 10,000 µg/mL H2O 500mL CRM
ICP-116 10,000 µg/mL H2O 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8529 1,000 µg/mL H2O 100mL CRM
5190-8530 1,000 µg/mL H2O 500mL CRM
ICP-016 1,000 µg/mL H2O 125mL RM

Sulfur

17

Cl

17
Atomic number
35.45
Atomic weight
Cl
Element symbol
12.97
First ionization potential (eV)

23.81
Second ionization potential (eV)
-102
Melting point (°C)/1 atm

-34
Boiling point (°C)/1 atm

Chlorine

Atomic weight: 35.453

Isotope abundance: 35 (75.76%)*; 37 (24.24%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +1, -1, -2

Chlorine

18

Ar

18
Atomic number
39.95
Atomic weight
Ar
Element symbol
15.76
First ionization potential (eV)

27.63
Second ionization potential (eV)
-189
Melting point (°C)/1 atm

-186
Boiling point (°C)/1 atm

Argon

Atomic weight: 39.948

Isotope abundance: 36 (0.34%); 38 (0.06%); 40 (99.60%)

Oxidation states: 0

Argon

19

K

19
Atomic number
39.10
Atomic weight
K
Element symbol
4.34
First ionization potential (eV)

31.63
Second ionization potential (eV)
64
Melting point (°C)/1 atm

759
Boiling point (°C)/1 atm

Potassium

Atomic weight: 39.0983

Chemical form in solution: K+(aq)

Isotope abundance: 39 (93.26%)*; 40 (0.01%); 41 (6.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8304 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8305 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-219 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8432 10,000 µg/mL 5% HNO3 100mL CRM
5190-8433 10,000 µg/mL 5% HNO3 500mL CRM
ICP-119 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8503 1,000 µg/mL 5% HNO3 100mL CRM
5190-8504 1,000 µg/mL 5% HNO3 500mL CRM
ICP-019 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-419 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610104200 Coded Potassium (K) coded single element hollow cathode lamp
5610126200 Uncoded Potassium (K) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Potassium

20

Ca

20
Atomic number
40.08
Atomic weight
Ca
Element symbol
6.11
First ionization potential (eV)

11.87
Second ionization potential (eV)
842
Melting point (°C)/1 atm

1484
Boiling point (°C)/1 atm

Calcium

Atomic weight: 40.078

Chemical form in solution: Ca(H2O)6+2

Isotope abundance: 40 (96.941%); 42 (0.647%); 43 (0.135%)*; 44 (2.086%)*; 46 (0.004%); 48 (0.187%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8272 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8273 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-220 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8368 10,000 µg/mL 5% HNO3 100mL CRM
5190-8369 10,000 µg/mL 5% HNO3 500mL CRM
ICP-120 10,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8329 1,000 µg/mL 5% HNO3 100mL CRM
5190-8330 1,000 µg/mL 5% HNO3 500mL CRM
ICP-020 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-420 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610101000 Coded Calcium (Ca) coded single element hollow cathode lamp
5610122900 Uncoded Calcium (Ca) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Calcium

21

Sc

21
Atomic number
44.96
Atomic weight
Sc
Element symbol
6.56
First ionization potential (eV)

12.80
Second ionization potential (eV)
1541
Melting point (°C)/1 atm

2836
Boiling point (°C)/1 atm

Scandium

Atomic weight: 44.95591

Chemical form in solution: Sc(H2O)6+2

Isotope abundance: 45 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container. Small atomic radius increases hydrolysis requiring higher acid levels than other Rare Earths.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-221 1,000 µg/mL 5% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8446 10,000 µg/mL 5% HNO3 100mL CRM
5190-8447 10,000 µg/mL 5% HNO3 500mL CRM
ICP-121 10,000 µg/mL 10% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8517 1,000 µg/mL 5% HNO3 100mL CRM
5190-8518 1,000 µg/mL 5% HNO3 500mL CRM
ICP-021 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8578 10 µg/mL 2% HNO3 100mL CRM
IMS-113 100 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610126900 Uncoded Scandium (Sc) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Scandium

22

Ti

22
Atomic number
47.87
Atomic weight
Ti
Element symbol
6.83
First ionization potential (eV)

13.58
Second ionization potential (eV)
1670
Melting point (°C)/1 atm

3287
Boiling point (°C)/1 atm

Titanium

Atomic weight: 47.88

Chemical form in solution: Ti(F)6-2

Isotope abundance: 46 (8.25%); 47 (7.44%)*; 48 (73.72%); 49 (5.41%); 50 (5.18%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals) as the Ti(F)6-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Ti(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8320 1,000 µg/mL H2O 100 mL CRM
5190-8321 1,000 µg/mL H2O 500 mL CRM
IAA-222 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8224 10,000 µg/mL H2O 100mL CRM
5190-8225 10,000 µg/mL H2O 500mL CRM
ICP-122 10,000 µg/mL 2% HNO3 with 0.1% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8545 1,000 µg/mL H2O 100mL CRM
5190-8546 1,000 µg/mL H2O 500mL CRM
ICP-022 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-422 10 µg/mL 0.5% HNO3 with 0.1% HF 125mL CRM

Single element lamps

Part No. Type Description
5610106200 Coded Titanium (Ti) coded single element hollow cathode lamp
5610128200 Uncoded Titanium (Ti) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Titanium

23

V

23
Atomic number
50.94
Atomic weight
V
Element symbol
6.75
First ionization potential (eV)

14.62
Second ionization potential (eV)
1910
Melting point (°C)/1 atm

3407
Boiling point (°C)/1 atm

Vanadium

Atomic weight: 50.9415

Chemical form in solution: H2V10O284-

Isotope abundance: 50 (0.25%); 51 (99.75%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8323 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8324 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-223 1,000 µg/mL 5% HNO3 with 1% HF 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8228 10,000 µg/mL 5% HNO3 100mL CRM
5190-8229 10,000 µg/mL 5% HNO3 500mL CRM
ICP-123 10,000 µg/mL 10% HNO3 with 2% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8551 1,000 µg/mL 5% HNO3 100mL CRM
5190-8552 1,000 µg/mL 5% HNO3 500mL CRM
ICP-023 1,000 µg/mL 5% HNO3 with 1% HF 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8585 10 µg/mL 5% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610106500 Coded Vanadium (V) coded single element hollow cathode lamp
5610128500 Uncoded Vanadium (V) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Vanadium

24

Cr

24
Atomic number
52.00
Atomic weight
Cr
Element symbol
6.77
First ionization potential (eV)

16.49
Second ionization potential (eV)
1907
Melting point (°C)/1 atm

2671
Boiling point (°C)/1 atm

Chromium

Atomic weight: 51.9961

Chemical form in solution: Cr(H2O)63+

Isotope abundance: 50 (4.345%); 52 (83.79%)*; 53 (9.50%); 54 (2.365%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8275 1,000 µg/mL 5% HCl 100 mL CRM
5190-8276 1,000 µg/mL 5% HCl 500 mL CRM
IAA-224 1,000 µg/mL 2% HNO3 125 mL RM
ICP-324A 1,000 µg/mL H2O 100 mL CRM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8374 10,000 µg/mL 5% HNO3 100mL CRM
5190-8375 10,000 µg/mL 5% HNO3 500mL CRM
ICP-124 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8344 1,000 µg/mL 5% HNO3 100mL CRM
5190-8345 1,000 µg/mL 5% HNO3 500mL CRM
ICP-024 1,000 µg/mL H2O tr. HNO3 125mL RM
ICP-024A 1,000 µg/mL H2O 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8568 10 µg/mL 2% HNO3 100mL CRM
ICP-424A 10 µg/mL H2O 125mL CRM

Single element lamps

Part No. Type Description
5610101200 Coded Chromium (Cr) coded single element hollow cathode lamp
5610123100 Uncoded Chromium (Cr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Chromium

25

Mn

25
Atomic number
54.94
Atomic weight
Mn
Element symbol
7.43
First ionization potential (eV)

15.64
Second ionization potential (eV)
1246
Melting point (°C)/1 atm

2061
Boiling point (°C)/1 atm

Manganese

Atomic weight: 54.9380

Chemical form in solution: Mn(H2O)62+

Isotope abundance: 55 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8293 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8294 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-225 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8414 10,000 µg/mL 5% HNO3 100mL CRM
5190-8415 10,000 µg/mL 5% HNO3 500mL CRM
ICP-125 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8483 1,000 µg/mL 5% HNO3 100mL CRM
5190-8484 1,000 µg/mL 5% HNO3 500mL CRM
ICP-025 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8574 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610103300 Coded Manganese (Mn) coded single element hollow cathode lamp
5610125200 Uncoded Manganese (Mn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133700 High intensity UltrAA Manganese (Mn) high intensity UltrAA coded single element hollow cathode lamp

Manganese

26

Fe

26
Atomic number
55.85
Atomic weight
Fe
Element symbol
7.90
First ionization potential (eV)

16.19
Second ionization potential (eV)
1538
Melting point (°C)/1 atm

2861
Boiling point (°C)/1 atm

Iron

Atomic weight: 55.847

Chemical form in solution: Fe(H2O)63+

Isotope abundance: 54 (5.85%); 56 (91.75%)*; 57 (2.12%); 58 (0.28%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8285 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8286 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-226 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8402 10,000 µg/mL 5% HNO3 100mL CRM
5190-8403 10,000 µg/mL 5% HNO3 500mL CRM
ICP-126 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8471 1,000 µg/mL 5% HNO3 100mL CRM
5190-8472 1,000 µg/mL 5% HNO3 500mL CRM
ICP-026 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-426 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610102700 Coded Iron (Fe) coded single element hollow cathode lamp
5610124600 Uncoded Iron (Fe) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108600 High intensity UltrAA Iron (Fe) high intensity UltrAA coded single element hollow cathode lamp

Iron

27

Co

27
Atomic number
58.93
Atomic weight
Co
Element symbol
7.88
First ionization potential (eV)

17.08
Second ionization potential (eV)
1495
Melting point (°C)/1 atm

2927
Boiling point (°C)/1 atm

Cobalt

Atomic weight: 58.9332

Chemical form in solution: Co(H2O)62+

Isotope abundance: 59 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8277 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8278 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-227 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8376 10,000 µg/mL 5% HNO3 100mL CRM
5190-8377 10,000 µg/mL 5% HNO3 500mL CRM
ICP-127 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8346 1,000 µg/mL 5% HNO3 100mL CRM
5190-8347 1,000 µg/mL 5% HNO3 500mL CRM
ICP-027 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
8500-6947 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610101300 Coded Cobalt (Co) coded single element hollow cathode lamp
5610123200 Uncoded Cobalt (Co) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134100 High intensity UltrAA Cobalt (Co) high intensity UltrAA coded single element hollow cathode lamp

Cobalt

28

Ni

28
Atomic number
58.69
Atomic weight
Ni
Element symbol
7.64
First ionization potential (eV)

18.17
Second ionization potential (eV)
1455
Melting point (°C)/1 atm

2913
Boiling point (°C)/1 atm

Nickel

Atomic weight: 58.6934

Chemical form in solution: Ni(H2O)62+

Isotope abundance: 58 (68.08%); 60 (26.22%)*; 61 (1.14%); 62 (3.63%); 64 (0.93%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8298 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8299 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-228 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8422 10,000 µg/mL 5% HNO3 100mL CRM
5190-8423 10,000 µg/mL 5% HNO3 500mL CRM
ICP-128 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8491 1,000 µg/mL 5% HNO3 100mL CRM
5190-8492 1,000 µg/mL 5% HNO3 500mL CRM
ICP-028 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8576 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610103700 Coded Nickel (Ni) coded single element hollow cathode lamp
5610125600 Uncoded Nickel (Ni) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108500 High intensity UltrAA Nickel (Ni) high intensity UltrAA coded single element hollow cathode lamp

Nickel

29

Cu

29
Atomic number
63.55
Atomic weight
Cu
Element symbol
7.73
First ionization potential (eV)

20.29
Second ionization potential (eV)
1085
Melting point (°C)/1 atm

2560
Boiling point (°C)/1 atm

Copper

Atomic weight: 63.546

Chemical form in solution: Cu(H2O)62+

Isotope abundance: 63 (69.15%)*; 65 (30.85%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8279 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8280 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-229 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8378 10,000 µg/mL 5% HNO3 100mL CRM
5190-8379 10,000 µg/mL 5% HNO3 500mL CRM
ICP-129 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8348 1,000 µg/mL 5% HNO3 100mL CRM
5190-8349 1,000 µg/mL 5% HNO3 500mL CRM
ICP-029 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8569 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610101400 Coded Copper (Cu) coded single element hollow cathode lamp
5610123300 Uncoded Copper (Cu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Copper

30

Zn

30
Atomic number
65.38
Atomic weight
Zn
Element symbol
9.39
First ionization potential (eV)

17.96
Second ionization potential (eV)
420
Melting point (°C)/1 atm

907
Boiling point (°C)/1 atm

Zinc

Atomic weight: 65.38

Chemical form in solution: Zn(OH)(aq)+

Isotope abundance: 64 (49.17%); 66 (27.73%)*; 67 (4.04%); 68 (18.45%); 70 (0.61%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8325 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8326 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-230 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8234 10,000 µg/mL 5% HNO3 100mL CRM
5190-8235 10,000 µg/mL 5% HNO3 500mL CRM
ICP-130 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8557 1,000 µg/mL 5% HNO3 100mL CRM
5190-8558 1,000 µg/mL 5% HNO3 500mL CRM
ICP-030 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8587 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610106800 Coded Zinc (Zn) coded single element hollow cathode lamp
5610128800 Uncoded Zinc (Zn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Zinc

31

Ga

31
Atomic number
69.72
Atomic weight
Ga
Element symbol
6.00
First ionization potential (eV)

20.52
Second ionization potential (eV)
30
Melting point (°C)/1 atm

2229
Boiling point (°C)/1 atm

Gallium

Atomic weight: 69.723

Chemical form in solution: Ga(H2O)6+3

Isotope abundance: 69 (60.11%); 71 (39.89%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-231 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8388 10,000 µg/mL 5% HNO3 100mL CRM
ICP-131 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8457 1,000 µg/mL 5% HNO3 tr HCl 100mL CRM
5190-8460 1,000 µg/mL 5% HNO3 tr HF 500mL CRM
ICP-031 1,000 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610123800 Uncoded Gallium (Ga) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Gallium

32

Ge

32
Atomic number
72.63
Atomic weight
Ge
Element symbol
7.90
First ionization potential (eV)

15.93
Second ionization potential (eV)
938
Melting point (°C)/1 atm

2833
Boiling point (°C)/1 atm

Germanium

Atomic weight: 72.59

Chemical form in solution: Ge(OH)x(F)y2-

Isotope abundance: 70 (20.57%); 72 (27.45%)*; 73 (7.75%); 74 (36.50%); 76 (7.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown alone or mixed with all other metals as the Ge(OH)x(F)y2-. 1-10,000 ppm single element solutions as the Ge(OH)x(F)y2- chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-232 1,000 µg/mL 0.8% HF 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8390 10,000 µg/mL 5% HNO3 tr. HF 100mL CRM
ICP-132 10,000 µg/mL 0.2% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8459 1,000 µg/mL 5% HNO3 100mL CRM
ICP-032 1,000 µg/mL 0.8% HF 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8592 10 µg/mL 2% HNO3 tr. HF 100mL CRM

Single element lamps

Part No. Type Description
5610123900 Uncoded Germanium (Ge) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134300 High intensity UltrAA Germanium (Ge) high intensity UltrAA coded single element hollow cathode lamp

Germanium

33

As

33
Atomic number
74.92
Atomic weight
As
Element symbol
9.79
First ionization potential (eV)

18.59
Second ionization potential (eV)
616
Melting point (°C)/1 atm

616
Boiling point (°C)/1 atm

Arsenic

Atomic weight: 74.9216

Chemical form in solution: H3AsO4 and HAsO2

Isotope abundance: 75 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5/+3mix, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stable for months alone or mixed with other elements at equivalent levels—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8260 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8261 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-233 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8356 10,000 µg/mL 5% HNO3 100mL CRM
5190-8357 10,000 µg/mL 5% HNO3 500mL CRM
ICP-133 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8246 1,000 µg/mL 5% HNO3 100mL CRM
5190-8247 1,000 µg/mL 5% HNO3 500mL CRM
ICP-033 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8563 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100300 Coded Arsenic (As) coded single element hollow cathode lamp
5610122200 Uncoded Arsenic (As) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108100 High intensity UltrAA Arsenic (As) high intensity UltrAA coded single element hollow cathode lamp

Arsenic

34

Se

34
Atomic number
78.97
Atomic weight
Se
Element symbol
9.75
First ionization potential (eV)

21.19
Second ionization potential (eV)
221
Melting point (°C)/1 atm

685
Boiling point (°C)/1 atm

Selenium

Atomic weight: 78.96

Chemical form in solution: H2SeO3

Isotope abundance: 74 (0.89%); 76 (9.37%); 77 (7.63%); 78 (23.77%)*; 80 (49.61%); 82 (8.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +4, +1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months alone or mixed with other elements at equivalent levels in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8306 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8307 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-234 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8448 10,000 µg/mL 5% HNO3 100mL CRM
5190-8449 10,000 µg/mL 5% HNO3 500mL CRM
ICP-134 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8519 1,000 µg/mL 5% HNO3 100mL CRM
5190-8520 1,000 µg/mL 5% HNO3 500mL CRM
ICP-034 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8579 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610105000 Coded Selenium (Se) coded single element hollow cathode lamp
5610127000 Uncoded Selenium (Se) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108300 High intensity UltrAA Selenium (Se) high intensity UltrAA coded single element hollow cathode lamp

Selenium

35

Br

35
Atomic number
79.90
Atomic weight
Br
Element symbol
11.81
First ionization potential (eV)

21.59
Second ionization potential (eV)
-7
Melting point (°C)/1 atm

59
Boiling point (°C)/1 atm

Bromine

Atomic weight: 79.904

Isotope abundance: 79 (50.69%)*; 81 (49.31%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +4, +3, +1, -1

Bromine

36

Kr

36
Atomic number
83.80
Atomic weight
Kr
Element symbol
14.00
First ionization potential (eV)

24.36
Second ionization potential (eV)
-157
Melting point (°C)/1 atm

-153
Boiling point (°C)/1 atm

Krypton

Atomic weight: 83.8

Isotope abundance: 78 (0.35%); 80 (2.29%); 82 (11.59%); 83 (11.50%); 84 (56.99%); 86 (17.28%)

Oxidation states: +2

Krypton

37

Rb

37
Atomic number
85.47
Atomic weight
Rb
Element symbol
4.18
First ionization potential (eV)

27.29
Second ionization potential (eV)
39.3
Melting point (°C)/1 atm

688
Boiling point (°C)/1 atm

Rubidium

Atomic weight: 85.4678

Chemical form in solution: Rb+(aq)

Isotope abundance: 85 (72.17%)*; 87 (27.83%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1-1% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8440 10,000 µg/mL 5% HNO3 100mL CRM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8511 1,000 µg/mL 5% HNO3 100mL CRM
ICP-037 1,000 µg/mL 1% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610126600 Uncoded Rubidium (Rb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Rubidium

38

Sr

38
Atomic number
87.62
Atomic weight
Sr
Element symbol
5.69
First ionization potential (eV)

11.03
Second ionization potential (eV)
777
Melting point (°C)/1 atm

1377
Boiling point (°C)/1 atm

Strontium

Atomic weight: 87.62

Chemical form in solution: Sr(H2O)6+2

Isotope abundance: 84 (0.56%); 86 (9.86%); 87 (7.00%); 88 (82.58%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8313 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8314 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-238 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8207 10,000 µg/mL 5% HNO3 100mL CRM
5190-8208 10,000 µg/mL 5% HNO3 500mL CRM
ICP-138 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8527 1,000 µg/mL 5% HNO3 100mL CRM
5190-8528 1,000 µg/mL 5% HNO3 500mL CRM
ICP-038 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8581 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610105400 Coded Strontium (Sr) coded single element hollow cathode lamp
5610127400 Uncoded Strontium (Sr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Strontium

39

Y

39
Atomic number
88.91
Atomic weight
Y
Element symbol
6.22
First ionization potential (eV)

12.22
Second ionization potential (eV)
1522
Melting point (°C)/1 atm

3345
Boiling point (°C)/1 atm

Yttrium

Atomic weight: 88.9059

Chemical form in solution: Y(OH)(H2O)x+2

Isotope abundance: 89 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-239 1,000 µg/mL 5% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8232 10,000 µg/mL 5% HNO3 100mL CRM
5190-8233 10,000 µg/mL 5% HNO3 500mL CRM
ICP-139 10,000 µg/mL 5% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8555 1,000 µg/mL 5% HNO3 100mL CRM
5190-8556 1,000 µg/mL 5% HNO3 500mL CRM
ICP-039 1,000 µg/mL 5% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8586 10 µg/mL 2% HNO3 100mL CRM
IMS-115 100 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610128700 Uncoded Yttrium (Y) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Yttrium

40

Zr

40
Atomic number
91.22
Atomic weight
Zr
Element symbol
6.63
First ionization potential (eV)

13.1
Second ionization potential (eV)
1854
Melting point (°C)/1 atm

4406
Boiling point (°C)/1 atm

Zirconium

Atomic weight: 91.224

Chemical form in solution: Zr(F)6-2

Isotope abundance: 90 (51.45%)*; 91 (11.22%); 92 (17.15%); 94 (17.38%); 96 (2.80%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2, 0, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Zr(F)6-2 + Zr(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Zr(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8327 1,000 µg/mL 5% HNO3 100 mL CRM
IAA-240 1,000 µg/mL 5% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8236 10,000 µg/mL 5% HNO3 100mL CRM
ICP-140 10,000 µg/mL 5% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8559 1,000 µg/mL 5% HCl 100mL CRM
5190-8560 1,000 µg/mL 5% HCl 500mL CRM
ICP-040 1,000 µg/mL 5% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610106900 Coded Zirconium (Zr) coded single element hollow cathode lamp
5610128900 Uncoded Zirconium (Zr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Zirconium

41

Nb

41
Atomic number
92.91
Atomic weight
Nb
Element symbol
6.76
First ionization potential (eV)

14.0
Second ionization potential (eV)
2477
Melting point (°C)/1 atm

4741
Boiling point (°C)/1 atm

Niobium

Atomic weight: 92.9064

Chemical form in solution: NbOF5-2

Isotope abundance: 93 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2, +1, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the NbOF5-2 for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the NbOF5-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8493 1,000 µg/mL 2% HF 100mL CRM
ICP-041 1,000 µg/mL 0.2% HF 125mL RM

Single element lamps

Part No. Type Description
5610103800 Coded Niobium (Nb) coded single element hollow cathode lamp
5610125700 Uncoded Niobium (Nb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Niobium

42

Mo

42
Atomic number
95.95
Atomic weight
Mo
Element symbol
7.09
First ionization potential (eV)

16.16
Second ionization potential (eV)
2622
Melting point (°C)/1 atm

4639
Boiling point (°C)/1 atm

Molybdenum

Atomic weight: 95.96

Chemical form in solution: MoO4-2 (chem. form as received)

Isotope abundance: 92 (14.53%); 94 (9.15%); 95 (15.84%)*; 96 (16.67%); 97 (9.60%); 98 (24.39%); 100 (9.82%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the MoOF5-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the MoO4-2 chemically stable for years in 1% NH4OH in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8297 1,000 µg/mL 1% HN4OH 100 mL CRM
IAA-242 1,000 µg/mL 2% NH4OH 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8418 10,000 µg/mL 1% NH4OH 100mL CRM
5190-8419 10,000 µg/mL 1% NH4OH 500mL CRM
ICP-142 10,000 µg/mL 4% NH4OH 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8487 1,000 µg/mL 1% NH4OH 100mL CRM
5190-8488 1,000 µg/mL 1% NH4OH 500mL CRM
ICP-042 1,000 µg/mL 2% NH4OH 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-442 10 µg/mL 0.5% NH4OH 125mL CRM

Single element lamps

Part No. Type Description
5610103500 Coded Molybdenum (Mo) coded single element hollow cathode lamp
5610125400 Uncoded Molybdenum (Mo) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Molybdenum

43

Tc

43
Atomic number
(98)
Atomic weight
Tc
Element symbol
7.28
First ionization potential (eV)

15.26
Second ionization potential (eV)
2157
Melting point (°C)/1 atm

4262
Boiling point (°C)/1 atm

Technetium

Atomic weight: (98)

Oxidation states: +7, +6, +5, +4, 0, -1

Technetium

44

Ru

44
Atomic number
101.1
Atomic weight
Ru
Element symbol
7.36
First ionization potential (eV)

16.76
Second ionization potential (eV)
2333
Melting point (°C)/1 atm

4147
Boiling point (°C)/1 atm

Ruthenium

Atomic weight: 101.07

Chemical form in solution: RuCl6

Isotope abundance: 96 (5.54%); 98 (1.87%); 99 (12.76%); 100 (12.60%); 101 (17.06%)*; 102 (31.55%); 104 (18.62%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +8, +7, +6, +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8442 10,000 µg/mL 20% HCl 100mL CRM
5190-8443 10,000 µg/mL 20% HCl 500mL CRM
ICP-144 10,000 µg/mL 10% HCl 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8513 1,000 µg/mL 20% HCl 100mL CRM
ICP-044 1,000 µg/mL 5% HCl 125mL RM

Single element lamps

Part No. Type Description
5610126700 Uncoded Ruthenium (Ru) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Ruthenium

45

Rh

45
Atomic number
102.9
Atomic weight
Rh
Element symbol
7.46
First ionization potential (eV)

18.08
Second ionization potential (eV)
1963
Melting point (°C)/1 atm

3695
Boiling point (°C)/1 atm

Rhodium

Atomic weight: 102.91

Chemical form in solution: RhCl6-3

Isotope abundance: 103 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-245 1,000 µg/mL 5% HCl 125 mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8509 1,000 µg/mL 20% HCl 100mL CRM
5190-8510 1,000 µg/mL 20% HCl 500mL CRM
ICP-045 1,000 µg/mL H2O tr. HCl 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
8500-6945 10 µg/mL 2% HCl 100mL CRM

Single element lamps

Part No. Type Description
5610104500 Coded Rhodium (Rh) coded single element hollow cathode lamp
5610126500 Uncoded Rhodium (Rh) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Rhodium

46

Pd

46
Atomic number
106.4
Atomic weight
Pd
Element symbol
8.34
First ionization potential (eV)

19.43
Second ionization potential (eV)
1555
Melting point (°C)/1 atm

2963
Boiling point (°C)/1 atm

Palladium

Atomic weight: 106.42

Chemical form in solution: Pd(H2O)62+

Isotope abundance: 102 (1.02%); 104 (11.14%); 105 (22.33%)*; 106 (27.33%); 108 (26.46%); 110 (11.72%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2 ppb Pd is stable for 1 day in 1% HNO3/LDPE container. 10 ppb is stable for 3 days in 1% HNO3/LDPE container. 100 ppb is stable for ≥ 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8300 1,000 µg/mL 20% HCl 100 mL CRM
5190-8301 1,000 µg/mL 20% HCl 500 mL CRM
IAA-246 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8426 10,000 µg/mL 10% HNO3 100mL CRM
ICP-146 10,000 µg/mL 5% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8497 1,000 µg/mL 5% HNO3 100mL CRM
5190-8498 1,000 µg/mL 5% HNO3 500mL CRM
ICP-046 1,000 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610104000 Coded Palladium (Pd) coded single element hollow cathode lamp
5610125900 Uncoded Palladium (Pd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135800 High intensity UltrAA Palladium (Pd) high intensity UltrAA coded single element hollow cathode lamp

Palladium

47

Ag

47
Atomic number
107.9
Atomic weight
Ag
Element symbol
7.58
First ionization potential (eV)

21.48
Second ionization potential (eV)
962
Melting point (°C)/1 atm

2162
Boiling point (°C)/1 atm

Silver

Atomic weight: 107.8682

Chemical form in solution: Ag(H2O)6+

Isotope abundance: 107 (51.84%)*; 109 (48.16%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for 75+ days when mixed with equivalent levels of all other elements including the precious metals (where chloride is present) when in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (trace levels of HCl or Cl- will form AgCl and will photoreduce to Ag0)
  • HCl (35%+ HCl will keep 100+ μg/mL of Ag+ in solution. HCl can be lowered to 10% to keep 10 μg/mL Ag in solution)
  • H2SO4 (trace levels of Cl- will photoreduce to Ag0, which is photosensitive)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8309 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8310 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-247 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8452 10,000 µg/mL 5% HNO3 100mL CRM
5190-8453 10,000 µg/mL 5% HNO3 500mL CRM
ICP-147 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8523 1,000 µg/mL 5% HNO3 100mL CRM
5190-8524 1,000 µg/mL 5% HNO3 500mL CRM
ICP-047 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8580 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610105200 Coded Silver (Ag) coded single element hollow cathode lamp
5610127200 Uncoded Silver (Ag) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Silver

48

Cd

48
Atomic number
112.4
Atomic weight
Cd
Element symbol
8.99
First ionization potential (eV)

16.91
Second ionization potential (eV)
321
Melting point (°C)/1 atm

767
Boiling point (°C)/1 atm

Cadmium

Atomic weight: 112.41

Chemical form in solution: Cd2(OH)(aq)3+ and Cd(OH)(aq)+

Isotope abundance: 106 (1.25%); 108 (0.89%); 110 (12.49%); 111 (12.80%)*; 112 (24.13%); 113 (12.22%); 114 (28.73%); 116 (7.49%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8270 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8271 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-248 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8366 10,000 µg/mL 5% HNO3 100mL CRM
5190-8367 10,000 µg/mL 5% HNO3 500mL CRM
ICP-148 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-9414 1,000 µg/mL 5% HNO3 100mL CRM
5190-8328 1,000 µg/mL 5% HNO3 500mL CRM
ICP-048 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8567 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100800 Coded Cadmium (Cd) coded single element hollow cathode lamp
5610122700 Uncoded Cadmium (Cd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Cadmium

49

In

49
Atomic number
114.8
Atomic weight
In
Element symbol
5.79
First ionization potential (eV)

18.87
Second ionization potential (eV)
157
Melting point (°C)/1 atm

2027
Boiling point (°C)/1 atm

Indium

Atomic weight: 114.82

Chemical form in solution: In(H2O)6+3

Isotope abundance: 113 (4.29%); 115 (95.71%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8284 1,000 µg/mL 5% HNO3 100 mL CRM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8398 10,000 µg/mL 5% HNO3 100mL CRM
ICP-149 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8467 1,000 µg/mL 5% HNO3 100mL CRM
5190-8468 1,000 µg/mL 5% HNO3 500mL CRM
ICP-049 1,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
8500-6946 10 µg/mL 2% HNO3 100mL CRM
IMS-112 100 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610124400 Uncoded Indium (In) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Indium

50

Sn

50
Atomic number
118.7
Atomic weight
Sn
Element symbol
7.34
First ionization potential (eV)

14.63
Second ionization potential (eV)
232
Melting point (°C)/1 atm

2586
Boiling point (°C)/1 atm

Tin

Atomic weight: 118.710

Chemical form in solution: Sn(OH)xFy2-

Isotope abundance: 112 (0.97%); 114 (0.66%); 115 (0.34%); 116 (14.54%); 117 (7.68%); 118 (24.22%)*; 119 (8.59%); 120 (32.58%); 122 (4.63%); 124 (5.79%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Sn(OH)xFy2- for 1 year in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Sn(OH)xFy2- are chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (if complexed with F- / tartaric acid complex can be diluted in HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (if complexed with F- / tartaric acid complex can be diluted in HNO3)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8318 1,000 µg/mL 20% HCl 100 mL CRM
5190-8319 1,000 µg/mL 20% HCl 500 mL CRM
IAA-250 1,000 µg/mL 2% HNO3 tr. 0.1% HF 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8221 10,000 µg/mL 20% HCl 100mL CRM
5190-8222 10,000 µg/mL 20% HCl 500mL CRM
ICP-150 10,000 µg/mL 2% HNO3 with 0.1% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8543 1,000 µg/mL 20% HCl 100mL CRM
5190-8544 1,000 µg/mL 20% HCl 500mL CRM
ICP-050 1,000 µg/mL H2O tr. HNO3 and HF 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8583 10 µg/mL 5% HCl 100mL CRM

Single element lamps

Part No. Type Description
5610106100 Coded Tin (Sn) coded single element hollow cathode lamp
5610128100 Uncoded Tin (Sn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133900 High intensity UltrAA Tin (Sn) high intensity UltrAA coded single element hollow cathode lamp

Tin

51

Sb

51
Atomic number
121.8
Atomic weight
Sb
Element symbol
8.61
First ionization potential (eV)

16.63
Second ionization potential (eV)
631
Melting point (°C)/1 atm

1587
Boiling point (°C)/1 atm

Antimony

Atomic weight: 121.75

Chemical form in solution: Sb(O)C4H4O6-

Isotope abundance: 121 (57.21%)*; 123 (42.79%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-2% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • Tartaric acid complex can be diluted HNO3
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • Tartaric acid complex can be compatible with H2SO4

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8258 1,000 µg/mL 30% HCl 100 mL CRM
5190-8259 1,000 µg/mL 30% HCl 500 mL CRM
IAA-251 1,000 µg/mL 2% HNO3 tr. 0.2% tartaric acid 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8354 10,000 µg/mL 1% HNO3 tr. tartaric acid 100mL CRM
5190-8355 10,000 µg/mL 1% HNO3 tr. tartaric acid 500mL CRM
ICP-151 10,000 µg/mL 2% HNO3 with 0.1% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8244 1,000 µg/mL 1% HNO3 tr. tartaric acid 100mL CRM
5190-8245 1,000 µg/mL 1% HNO3 tr. tartaric acid 500mL CRM
ICP-051 1,000 µg/mL 2% HNO3 tr. tartaric acid 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8562 10 µg/mL 1% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100200 Coded Antimony (Sb) coded single element hollow cathode lamp
5610122100 Uncoded Antimony (Sb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108000 High intensity UltrAA Antimony (Sb) high intensity UltrAA coded single element hollow cathode lamp

Antimony

52

Te

52
Atomic number
127.6
Atomic weight
Te
Element symbol
9.01
First ionization potential (eV)

18.60
Second ionization potential (eV)
450
Melting point (°C)/1 atm

988
Boiling point (°C)/1 atm

Tellurium

Atomic weight: 127.60

Chemical form in solution: H2TeO3 (HNO3 matrix), TeCl62- (HCl matrix)

Isotope abundance: 120 (0.09%); 122 (2.55%); 123 (0.89%); 124 (4.74%); 125 (7.07%)*; 126 (18.84%); 128 (31.74%); 130 (34.08%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +2, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months alone or mixed with other elements at equivalent levels in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (not soluable above 1000 μg/mL)
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8315 1,000 µg/mL 5% HNO3 100 mL CRM
IAA-252 1,000 µg/mL 10% HCl 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8213 10,000 µg/mL 30% HCl 100mL CRM
5190-8214 10,000 µg/mL 30% HCl 500mL CRM
ICP-152 10,000 µg/mL 40% HCl 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8533 1,000 µg/mL 30% HCl 100mL CRM
5190-8534 1,000 µg/mL 30% HCl 500mL CRM
ICP-052 1,000 µg/mL 10% HCl 125mL RM

Single element lamps

Part No. Type Description
5610105600 Coded Tellurium (Te) coded single element hollow cathode lamp
5610127600 Uncoded Tellurium (Te) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134000 High intensity UltrAA Tellurium (Te) high intensity UltrAA coded single element hollow cathode lamp

Tellurium

53

I

53
Atomic number
126.9
Atomic weight
I
Element symbol
10.45
First ionization potential (eV)

19.13
Second ionization potential (eV)
114
Melting point (°C)/1 atm

184
Boiling point (°C)/1 atm

Iodine

Atomic weight: 126.905

Isotope abundance: 127 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +3, +1, 0, -1

Iodine

54

Xe

54
Atomic number
131.3
Atomic weight
Xe
Element symbol
12.13
First ionization potential (eV)

20.97
Second ionization potential (eV)
-112
Melting point (°C)/1 atm

-108
Boiling point (°C)/1 atm

Xenon

Atomic weight: 131.29

Isotope abundance: 124 (0.09%); 126 (0.09%); 128 (1.92%); 129 (26.40%); 130 (4.07%); 131 (21.23%); 132 (26.91%); 134 (10.44%); 136 (8.86%)

Oxidation states: +8, +6, +4, +2

Xenon

55

Cs

55
Atomic number
132.9
Atomic weight
Cs
Element symbol
3.89
First ionization potential (eV)

23.16
Second ionization potential (eV)
28.5
Melting point (°C)/1 atm

671
Boiling point (°C)/1 atm

Cesium

Atomic weight: 132.9054

Chemical form in solution: Cs+(aq)

Isotope abundance: 133 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1% HNO3/LDPE container. Will crystallize out of higher (~ 5%) levels of HNO3 at > 1000 µg/mL.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8274 1,000 µg/mL 5% HNO3 100 mL CRM
1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8372 10,000 µg/mL 5% HNO3 100mL CRM
5190-8373 10,000 µg/mL 5% HNO3 500mL CRM
ICP-155 10,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8333 1,000 µg/mL 5% HNO3 100mL CRM
5190-8334 1,000 µg/mL 5% HNO3 500mL CRM
ICP-055 1,000 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610122800 Uncoded Cesium (Cs) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Cesium

56

Ba

56
Atomic number
137.3
Atomic weight
Ba
Element symbol
5.21
First ionization potential (eV)

10.00
Second ionization potential (eV)
727
Melting point (°C)/1 atm

1845
Boiling point (°C)/1 atm

Barium

Atomic weight: 137.33

Chemical form in solution: Ba(H2O)6+2

Isotope abundance: 130 (0.11%); 132 (0.10%); 134 (2.42%); 135 (6.59%); 136 (7.85%); 137 (11.23%)*; 138 (71.70%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8262 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8263 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-256 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8358 10,000 µg/mL 5% HNO3 100mL CRM
5190-8359 10,000 µg/mL 5% HNO3 500mL CRM
ICP-156 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8248 1,000 µg/mL 5% HNO3 100mL CRM
5190-8249 1,000 µg/mL 5% HNO3 500mL CRM
ICP-056 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8564 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610100400 Coded Barium (Ba) coded single element hollow cathode lamp
5610122300 Uncoded Barium (Ba) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Barium

 

La

72

Hf

72
Atomic number
178.5
Atomic weight
Hf
Element symbol
6.83
First ionization potential (eV)

15.0
Second ionization potential (eV)
2233
Melting point (°C)/1 atm

4600
Boiling point (°C)/1 atm

Hafnium

Atomic weight: 178.49

Chemical form in solution: Hf(F)6-2

Isotope abundance: 174 (0.16%); 176 (5.26%); 177 (18.60%); 178 (27.28%)*; 179 (13.62%); 180 (35.08%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable alone or mixed with all other metals that are at comparable levels as the Hf(F)6-2 + Hf(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Hf(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-172 10,000 µg/mL 0.2% HF 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8463 1,000 µg/mL 5% HCl 100mL CRM
ICP-072 1,000 µg/mL 1% HCl with 0.1% HF 125mL RM

Single element lamps

Part No. Type Description
5610102200 Coded Hafnium (Hf) coded single element hollow cathode lamp
5610124100 Uncoded Hafnium (Hf) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Hafnium

73

Ta

73
Atomic number
180.9
Atomic weight
Ta
Element symbol
7.55
First ionization potential (eV)
3017
Melting point (°C)/1 atm

5455
Boiling point (°C)/1 atm

Tantalum

Atomic weight: 180.9479

Chemical form in solution: TaOF6-3

Isotope abundance: 180 (0.01%); 181 (99.99%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +1, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the TaOF6-3, for 2 months at the 2-10 ppb level in 1% HNO3/LDPE container and for 5 months at the 100 ppb level under same conditions. 1-10,000 ppm single element solutions as the TaOF6-3 are chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should have excess HF present when diluted with HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (should have excess HF present when diluted with H2SO4)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8531 1,000 µg/mL 2% HF 100mL CRM
5190-8532 1,000 µg/mL 2% HF 500mL CRM
ICP-073 1,000 µg/mL 0.5% HF 125mL RM

Single element lamps

Part No. Type Description
5610105500 Coded Tantalum (Ta) coded single element hollow cathode lamp
5610127500 Uncoded Tantalum (Ta) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Tantalum

74

W

74
Atomic number
183.8
Atomic weight
W
Element symbol
7.86
First ionization potential (eV)

16.10
Second ionization potential (eV)
3414
Melting point (°C)/1 atm

5555
Boiling point (°C)/1 atm

Tungsten

Atomic weight: 183.85

Chemical form in solution: WOF5-2 (chem. form as received)

Isotope abundance: 180 (0.12%); 182 (26.50%)*; 183 (14.31%); 184 (30.64%); 186 (28.43%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, 0, -1, -2, -4

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the [WOF5]-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the [WOF5]-2 chemically stable for years in 1% HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should have excess HF present when diluted with HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (should have excess HF present when diluted with H2SO4)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-274 1,000 µg/mL 0.5% NH4OH 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8226 10,000 µg/mL 5% HNO3 tr. HF 100mL CRM
5190-8227 10,000 µg/mL 5% HNO3 tr. HF 500mL CRM
ICP-174 10,000 µg/mL 0.1% NH4OH 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8547 1,000 µg/mL 5% HNO3 tr. HF 100mL CRM
5190-8548 1,000 µg/mL 5% HNO3 tr. HF 500mL CRM
ICP-074 1,000 µg/mL 0.5% NH4OH 125mL RM

Single element lamps

Part No. Type Description
5610128300 Uncoded Tungsten (W) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Tungsten

75

Re

75
Atomic number
186.2
Atomic weight
Re
Element symbol
7.83
First ionization potential (eV)
3185
Melting point (°C)/1 atm

5590
Boiling point (°C)/1 atm

Rhenium

Atomic weight: 186.207

Chemical form in solution: ReO4-

Isotope abundance: 185 (37.40%)*; 187 (62.60%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8507 1,000 µg/mL 5% HNO3 100mL CRM
ICP-075 1,000 µg/mL 0.2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610104400 Coded Rhenium (Re) coded single element hollow cathode lamp
5610126400 Uncoded Rhenium (Re) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Rhenium

76

Os

76
Atomic number
190.2
Atomic weight
Os
Element symbol
8.44
First ionization potential (eV)
3033
Melting point (°C)/1 atm

5008
Boiling point (°C)/1 atm

Osmium

Atomic weight: 190.2

Chemical form in solution: OsCl62-

Isotope abundance: 184 (0.02%); 186 (1.59%); 187 (1.96%); 188 (13.24%); 189 (16.15%)*; 190 (26.26%); 192 (40.78%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +8, +7, +6, +5, +4, +3, +2, +1, 0, -2

Osmium

77

Ir

77
Atomic number
192.2
Atomic weight
Ir
Element symbol
8.97
First ionization potential (eV)
2446
Melting point (°C)/1 atm

4428
Boiling point (°C)/1 atm

Iridium

Atomic weight: 192.22

Chemical form in solution: IrCl6-2

Isotope abundance: 191 (37.3%); 193 (62.7%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if completed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-277 1,000 µg/mL 5% HCl 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8400 10,000 µg/mL 20% HCl 100mL CRM
ICP-177 10,000 µg/mL 10% HCl 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8469 1,000 µg/mL 20% HCl 100mL CRM
5190-8470 1,000 µg/mL 20% HCl 500mL CRM
ICP-077 1,000 µg/mL 5% HCl 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8570 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610102600 Coded Iridium (Ir) coded single element hollow cathode lamp
5610124500 Uncoded Iridium (Ir) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Iridium

78

Pt

78
Atomic number
195.1
Atomic weight
Pt
Element symbol
8.96
First ionization potential (eV)

18.56
Second ionization potential (eV)
1768
Melting point (°C)/1 atm

3825
Boiling point (°C)/1 atm

Platinum

Atomic weight: 195.08

Chemical form in solution: Pt(Cl)62-

Isotope abundance: 190 (0.012%); 192 (0.782%); 194 (32.86%); 195 (33.78%)*; 196 (25.21%); 198 (7.356%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +2, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-10 ppb Pt is stable for 2 months in 1% HNO3/LDPE container. 100 ppb is stable for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8302 1,000 µg/mL 20% HCl 100 mL CRM
5190-8303 1,000 µg/mL 20% HCl 500 mL CRM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8430 10,000 µg/mL 20% HCl 100mL CRM
ICP-178 10,000 µg/mL 10% HCl 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8501 1,000 µg/mL 20% HCl 100mL CRM
5190-8502 1,000 µg/mL 20% HCl 500mL CRM
ICP-078 1,000 µg/mL 2% HCl 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8577 10 µg/mL 5% HCl 100mL CRM

Single element lamps

Part No. Type Description
5610104100 Coded Platinum (Pt) coded single element hollow cathode lamp
5610126100 Uncoded Platinum (Pt) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135900 High intensity UltrAA Platinum (Pt) high intensity UltrAA coded single element hollow cathode lamp

Platinum

79

Au

79
Atomic number
197.0
Atomic weight
Au
Element symbol
9.23
First ionization potential (eV)

20.2
Second ionization potential (eV)
1064
Melting point (°C)/1 atm

2836
Boiling point (°C)/1 atm

Gold

Atomic weight: 196.9665

Chemical form in solution: Au(Cl)63-

Isotope abundance: 197 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +3, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2-10 ppb Au is stable for ≤ 1 day maximum in 1% HNO3/LDPE container. 100 ppb is stable for ≤ 2 days maximum in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if completed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8282 1,000 µg/mL 20% HCl 100 mL CRM
5190-8283 1,000 µg/mL 20% HCl 500 mL CRM
IAA-279 1,000 µg/mL 5% HCl 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8392 10,000 µg/mL 20% HCl 100mL CRM
5190-8393 10,000 µg/mL 20% HCl 500mL CRM
ICP-179 10,000 µg/mL 10% HCl 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8461 1,000 µg/mL 20% HCl 100mL CRM
5190-8462 1,000 µg/mL 20% HCl 500mL CRM
ICP-079 1,000 µg/mL H2O tr. HCl 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
8500-7000 100 µg/mL 2% HCl 100mL CRM

Single element lamps

Part No. Type Description
5610102100 Coded Gold (Au) coded single element hollow cathode lamp
5610124000 Uncoded Gold (Au) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610109000 High intensity UltrAA Gold (Au) high intensity UltrAA coded single element hollow cathode lamp

Gold

80

Hg

80
Atomic number
200.6
Atomic weight
Hg
Element symbol
10.44
First ionization potential (eV)

18.76
Second ionization potential (eV)
-39
Melting point (°C)/1 atm

357
Boiling point (°C)/1 atm

Mercury

Atomic weight: 200.59

Chemical form in solution: Hg(OH)(aq)+

Isotope abundance: 196 (0.15%); 198 (9.97%); 199 (16.87%); 200 (23.10%); 201 (13.18%)*; 202 (29.86%)*; 204 (6.87%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stable in 10% HNO3 packaged in borosilicate glass; NOT stable in 1% HNO3/ LDPE container. 1-100 ppm levels stable in 7% HNO3 packaged in borosilicate glass. 1000-10,000 ppm solutions are chemically stable for years in 5-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should be stored in borosilicate glass)
  • HCl (preferred matrix due to less adsorption)
  • H2SO4 (should be stored in borosilicate glass)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8295 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8296 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-280 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8416 10,000 µg/mL 5% HNO3 100mL CRM
5190-8417 10,000 µg/mL 5% HNO3 500mL CRM
ICP-180 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8485 1,000 µg/mL 5% HNO3 100mL CRM
5190-8486 1,000 µg/mL 5% HNO3 500mL CRM
ICP-080 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8575 10 µg/mL 5% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610103400 Coded Mercury (Hg) coded single element hollow cathode lamp
5610125300 Uncoded Mercury (Hg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Mercury

81

Tl

81
Atomic number
204.4
Atomic weight
Tl
Element symbol
6.11
First ionization potential (eV)

20.43
Second ionization potential (eV)
304
Melting point (°C)/1 atm

1473
Boiling point (°C)/1 atm

Thallium

Atomic weight: 204.383

Chemical form in solution: Tl(H2O)6+

Isotope abundance: 203 (29.52%); 205 (70.48%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8316 1,000 µg/mL 5% HNO3 100 mL CRM
IAA-281 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8217 10,000 µg/mL 5% HNO3 100mL CRM
ICP-181 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8537 1,000 µg/mL 5% HNO3 100mL CRM
5190-8538 1,000 µg/mL 5% HNO3 500mL CRM
ICP-081 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-481 10 µg/mL 0.5% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610105800 Coded Thallium (Tl) coded single element hollow cathode lamp
5610127800 Uncoded Thallium (Tl) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108400 High intensity UltrAA Thallium (Tl) high intensity UltrAA coded single element hollow cathode lamp

Thallium

82

Pb

82
Atomic number
207.2
Atomic weight
Pb
Element symbol
7.42
First ionization potential (eV)

15.03
Second ionization potential (eV)
327
Melting point (°C)/1 atm

1749
Boiling point (°C)/1 atm

Lead

Atomic weight: 207.2

Chemical form in solution: Pb(H2O)6+2

Isotope abundance: 204 (1.4%); 206 (24.1%); 207 (22.1%); 208 (52.4%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8287 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8288 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-282 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8406 10,000 µg/mL 5% HNO3 100mL CRM
5190-8407 10,000 µg/mL 5% HNO3 500mL CRM
ICP-182 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8475 1,000 µg/mL 5% HNO3 100mL CRM
5190-8476 1,000 µg/mL 5% HNO3 500mL CRM
ICP-082 1,000 µg/mL H2O tr. HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8571 10 µg/mL 2% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610102900 Coded Lead (Pb) coded single element hollow cathode lamp
5610124800 Uncoded Lead (Pb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108200 High intensity UltrAA Lead (Pb) high intensity UltrAA coded single element hollow cathode lamp

Lead

83

Bi

83
Atomic number
209.0
Atomic weight
Bi
Element symbol
7.29
First ionization potential (eV)

16.70
Second ionization potential (eV)
271
Melting point (°C)/1 atm

1564
Boiling point (°C)/1 atm

Bismuth

Atomic weight: 208.9804

Chemical form in solution: Bi(O)(H2O)x+

Isotope abundance: 209 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, +1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-7% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8266 1,000 µg/mL 5% HNO3 100 mL CRM
5190-8267 1,000 µg/mL 5% HNO3 500 mL CRM
IAA-283 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8362 10,000 µg/mL 5% HNO3 100mL CRM
5190-8363 10,000 µg/mL 5% HNO3 500mL CRM
ICP-183 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8252 1,000 µg/mL 5% HNO3 100mL CRM
5190-8253 1,000 µg/mL 5% HNO3 500mL CRM
ICP-083 1,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
8500-6936 10 µg/mL 2% HNO3 100mL CRM
IMS-111 100 µg/mL 2% HNO3 125mL CRM

Single element lamps

Part No. Type Description
5610100600 Coded Bismuth (Bi) coded single element hollow cathode lamp
5610122500 Uncoded Bismuth (Bi) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134200 High intensity UltrAA Bismuth (Bi) high intensity UltrAA coded single element hollow cathode lamp

Bismuth

84

Po

84
Atomic number
(209)
Atomic weight
Po
Element symbol
8.41
First ionization potential (eV)
254
Melting point (°C)/1 atm

962
Boiling point (°C)/1 atm

Polonium

Atomic weight: (209)

Oxidation states: +6, +4, +2, -2

Polonium

85

At

85
Atomic number
(210)
Atomic weight
At
Element symbol
 
300
Melting point (°C)/1 atm

350
Boiling point (°C)/1 atm

Astatine

Atomic weight: (210)

Oxidation states: +3, +1, -1

Astatine

86

Rn

86
Atomic number
(222)
Atomic weight
Rn
Element symbol
10.75
First ionization potential (eV)
-71
Melting point (°C)/1 atm

-62
Boiling point (°C)/1 atm

Radon

Atomic weight: (222)

Oxidation states: +2

Radon

87

Fr

87
Atomic number
(223)
Atomic weight
Fr
Element symbol
4.07
First ionization potential (eV)
21
Melting point (°C)/1 atm

650
Boiling point (°C)/1 atm

Francium

Atomic weight: (223)

Oxidation states: +1

Francium

88

Ra

88
Atomic number
(226)
Atomic weight
Ra
Element symbol
5.28
First ionization potential (eV)

10.15
Second ionization potential (eV)
696
Melting point (°C)/1 atm

1500
Boiling point (°C)/1 atm

Radium

Atomic weight: 226.025

Oxidation states: +2

Radium

 

Ac

104

Rf

104
Atomic number
(267)
Atomic weight
Rf
Element symbol
6.0
First ionization potential (eV)

Rutherfordium

Atomic weight: (267)

Rutherfordium

105

Db

105
Atomic number
(268)
Atomic weight
Db
Element symbol

Dubnium

Atomic weight: (268)

Dubnium

106

Sg

106
Atomic number
(271)
Atomic weight
Sg
Element symbol

Seaborgium

Atomic weight: (269)

Seaborgium

107

Bh

107
Atomic number
(272)
Atomic weight
Bh
Element symbol

Bohrium

Atomic weight: (270)

Bohrium

108

Hs

108
Atomic number
(270)
Atomic weight
Hs
Element symbol

Hassium

Atomic weight: (277)

Hassium

109

Mt

109
Atomic number
(276)
Atomic weight
Mt
Element symbol

Meitnerium

Atomic weight: (278)

Meitnerium

110

Ds

110
Atomic number
(281)
Atomic weight
Ds
Element symbol

Darmstadtium

Atomic weight: (281)

Darmstadtium

111

Rg

111
Atomic number
(280)
Atomic weight
Rg
Element symbol

Roentgenium

Atomic weight: (282)

Roentgenium

112

Cn

112
Atomic number
(285)
Atomic weight
Cn
Element symbol

Copernicium

Atomic weight: (285)

Copernicium

113

Nh

113
Atomic number
(284)
Atomic weight
Nh
Element symbol

Nihonium

Atomic weight: (284)

Nihonium

114

Fl

114
Atomic number
(289)
Atomic weight
Fl
Element symbol

Flerovium

Atomic weight: (289)

Flerovium

115

Mc

115
Atomic number
(288)
Atomic weight
Mc
Element symbol

Moscovium

Atomic weight: (288)

Moscovium

116

Lv

116
Atomic number
(293)
Atomic weight
Lv
Element symbol

Livermorium

Atomic weight: (293)

Livermorium

117

Ts

117
Atomic number
(294)
Atomic weight
Ts
Element symbol

Tennessine

Atomic weight: (294)

Tennessine

118

Og

118
Atomic number
(294)
Atomic weight
Og
Element symbol

Oganesson

Atomic weight: (294)

Oganesson

57

La

57
Atomic number
138.9
Atomic weight
La
Element symbol
5.58
First ionization potential (eV)

11.06
Second ionization potential (eV)
920
Melting point (°C)/1 atm

3464
Boiling point (°C)/1 atm

Lanthanum

Atomic weight: 138.9055

Chemical form in solution: La(OH)y(H2O)x+3-y

Isotope abundance: 138 (0.09%); 139 (99.91%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-257 1,000 µg/mL 1% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8404 10,000 µg/mL 5% HNO3 100mL CRM
5190-8405 10,000 µg/mL 5% HNO3 500mL CRM
ICP-157 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8473 1,000 µg/mL 5% HNO3 100mL CRM
5190-8474 1,000 µg/mL 5% HNO3 500mL CRM
ICP-057 1,000 µg/mL 1% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610124700 Uncoded Lanthanum (La) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Lanthanum

58

Ce

58
Atomic number
140.1
Atomic weight
Ce
Element symbol
5.54
First ionization potential (eV)

10.85
Second ionization potential (eV)
799
Melting point (°C)/1 atm

3443
Boiling point (°C)/1 atm

Cerium

Atomic weight: 140.12

Chemical form in solution: Ce(OH)y(H2O)x+4-y

Isotope abundance: 136 (0.19%); 138 (0.25%); 140 (88.45%)*; 142 (11.11%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-258 1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8370 10,000 µg/mL 5% HNO3 100mL CRM
5190-8371 10,000 µg/mL 5% HNO3 500mL CRM
ICP-158 10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8331 1,000 µg/mL 5% HNO3 100mL CRM
5190-8332 1,000 µg/mL 5% HNO3 500mL CRM
ICP-058 1,000 µg/mL 2% HNO3 125mL RM

Cerium

59

Pr

59
Atomic number
140.9
Atomic weight
Pr
Element symbol
5.47
First ionization potential (eV)

10.55
Second ionization potential (eV)
931
Melting point (°C)/1 atm

3520
Boiling point (°C)/1 atm

Praseodymium

Atomic weight: 140.9077

Chemical form in solution: Pr(OH)y(H2O)x+3-y

Isotope abundance: 141 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-259 1,000 µg/mL 1% HNO3 125 mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8505 1,000 µg/mL 5% HNO3 100mL CRM
ICP-059 1,000 µg/mL 1% HNO3 125mL RM

Praseodymium

60

Nd

60
Atomic number
144.2
Atomic weight
Nd
Element symbol
5.53
First ionization potential (eV)

10.72
Second ionization potential (eV)
1016
Melting point (°C)/1 atm

3074
Boiling point (°C)/1 atm

Neodymium

Atomic weight: 144.24

Chemical form in solution: Nd(OH)y(H2O)x+3-y

Isotope abundance: 142 (27.2%); 143 (12.2%); 144 (23.8%); 145 (8.3%); 146 (17.2%)*; 148 (5.7%); 150 (5.6%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8421 10,000 µg/mL 500mL CRM
ICP-160 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8489 1,000 µg/mL 5% HNO3 100mL CRM
5190-8490 1,000 µg/mL 5% HNO3 500mL CRM
ICP-060 1,000 µg/mL 2% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610103600 Coded Neodymium (Nd) coded single element hollow cathode lamp
5610125500 Uncoded Neodymium (Nd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Neodymium

61

Pm

61
Atomic number
(145)
Atomic weight
Pm
Element symbol
5.58
First ionization potential (eV)

10.90
Second ionization potential (eV)
1042
Melting point (°C)/1 atm

3000
Boiling point (°C)/1 atm

Promethium

Atomic weight: (145)

Oxidation states: +3

Promethium

62

Sm

62
Atomic number
150.4
Atomic weight
Sm
Element symbol
5.64
First ionization potential (eV)

11.07
Second ionization potential (eV)
1072
Melting point (°C)/1 atm

1794
Boiling point (°C)/1 atm

Samarium

Atomic weight: 150.36

Chemical form in solution: Sm(OH)y(H2O)x+3-y

Isotope abundance: 144 (3.07%); 147 (14.99%)*; 148 (11.24%); 149 (13.82%); 150 (7.38%); 152 (26.75%); 154 (22.75%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8515 1,000 µg/mL 5% HNO3 100mL CRM

Single element lamps

Part No. Type Description
5610126800 Uncoded Samarium (Sm) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Samarium

63

Eu

63
Atomic number
152.0
Atomic weight
Eu
Element symbol
5.67
First ionization potential (eV)

11.25
Second ionization potential (eV)
822
Melting point (°C)/1 atm

1529
Boiling point (°C)/1 atm

Europium

Atomic weight: 151.96

Chemical form in solution: Eu(OH)y(H2O)x+3-y

Isotope abundance: 151 (47.81%); 153 (52.19%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8385 10,000 µg/mL 5% HNO3 500mL CRM
ICP-163 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8239 1,000 µg/mL 5% HNO3 100mL CRM
ICP-063 1,000 µg/mL 1% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610123600 Uncoded Europium (Eu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Europium

64

Gd

64
Atomic number
157.3
Atomic weight
Gd
Element symbol
6.15
First ionization potential (eV)

12.09
Second ionization potential (eV)
1313
Melting point (°C)/1 atm

3273
Boiling point (°C)/1 atm

Gadolinium

Atomic weight: 157.25

Chemical form in solution: Gd(OH)x(H2O)y+3-x

Isotope abundance: 152 (0.2%); 154 (2.18%); 155 (14.80%); 156 (20.47%); 157 (15.65%)*; 158 (24.84%); 160 (21.86%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8386 10,000 µg/mL 5% HNO3 100mL CRM
5190-8387 10,000 µg/mL 5% HNO3 500mL CRM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8241 1,000 µg/mL 5% HNO3 100mL CRM
5190-8456 1,000 µg/mL 5% HNO3 500mL CRM
ICP-064 1,000 µg/mL 1% HNO3 125mL RM

Single element lamps

Part No. Type Description
5610123700 Uncoded Gadolinium (Gd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

Gadolinium

65

Tb

65
Atomic number
158.9
Atomic weight
Tb
Element symbol
5.86
First ionization potential (eV)

11.52
Second ionization potential (eV)
1359
Melting point (°C)/1 atm

3230
Boiling point (°C)/1 atm

Terbium

Atomic weight: 158.9254

Chemical form in solution: Tb(OH)x(H2O)y+3-x

Isotope abundance: 159 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8216 10,000 µg/mL 500mL CRM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8535 1,000 µg/mL 5% HNO3 100mL CRM
ICP-065 1,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8582 10 µg/mL 2% HNO3 100mL CRM
IMS-114 100 µg/mL 2% HNO3 125mL RM

Terbium

66

Dy

66
Atomic number
162.5
Atomic weight
Dy
Element symbol
5.94
First ionization potential (eV)

11.67
Second ionization potential (eV)
1412
Melting point (°C)/1 atm

2567
Boiling point (°C)/1 atm

Dysprosium

Atomic weight: 162.50

Chemical form in solution: Dy(OH)x(H2O)y+3-x

Isotope abundance: 156 (0.06%); 158 (0.09%); 160 (2.33%); 161 (18.89%); 162 (25.47%); 163 (24.90%)*; 164 (28.26%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8381 10,000 µg/mL 500mL CRM
ICP-166 10,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8350 1,000 µg/mL 5% HNO3 100mL CRM
ICP-066 1,000 µg/mL 1% HNO3 125mL RM

Dysprosium

67

Ho

67
Atomic number
164.9
Atomic weight
Ho
Element symbol
6.02
First ionization potential (eV)

11.80
Second ionization potential (eV)
1472
Melting point (°C)/1 atm

2700
Boiling point (°C)/1 atm

Holmium

Atomic weight: 164.9304

Chemical form in solution: Ho(OH)x(H2O)y+3-x

Isotope abundance: 165 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8465 1,000 µg/mL 5% HNO3 100mL CRM
ICP-067 1,000 µg/mL 1% HNO3 125mL RM

Holmium

68

Er

68
Atomic number
167.3
Atomic weight
Er
Element symbol
6.11
First ionization potential (eV)

11.93
Second ionization potential (eV)
1529
Melting point (°C)/1 atm

2868
Boiling point (°C)/1 atm

Erbium

Atomic weight: 167.26

Chemical form in solution: Er(OH)x(H2O)y+3-x

Isotope abundance: 162 (0.14%); 164 (1.60%); 166 (33.50%)*; 167 (22.87%); 168 (26.98%); 170 (14.91%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8237 1,000 µg/mL 5% HNO3 100mL CRM
ICP-068 1,000 µg/mL 2% HNO3 125mL RM

Erbium

69

Tm

69
Atomic number
168.9
Atomic weight
Tm
Element symbol
6.18
First ionization potential (eV)

12.05
Second ionization potential (eV)
1545
Melting point (°C)/1 atm

1950
Boiling point (°C)/1 atm

Thulium

Atomic weight: 168.9342

Chemical form in solution: Tm(OH)x(H2O)y+3-x

Isotope abundance: 169 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8541 1,000 µg/mL 5% HNO3 100mL CRM
ICP-069 1,000 µg/mL 2% HNO3 125mL RM

Thulium

70

Yb

70
Atomic number
173.1
Atomic weight
Yb
Element symbol
6.25
First ionization potential (eV)

12.18
Second ionization potential (eV)
824
Melting point (°C)/1 atm

1196
Boiling point (°C)/1 atm

Ytterbium

Atomic weight: 173.054

Chemical form in solution: Yb(OH)x(H2O)y+3-x

Isotope abundance: 168 (0.12%); 170 (2.98%); 171 (14.09%); 172 (21.68%)*; 173 (16.10%); 174 (32.03%); 176 (13.00%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
1,000 µg/mL 5% HNO3 100 mL CRM
1,000 µg/mL 5% HNO3 500 mL CRM
1,000 µg/mL 2% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
10,000 µg/mL 5% HNO3 100mL CRM
10,000 µg/mL 5% HNO3 500mL CRM
10,000 µg/mL 2% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8553 1,000 µg/mL 5% HNO3 100mL CRM
ICP-070 1,000 µg/mL 1% HNO3 125mL RM

Ytterbium

71

Lu

71
Atomic number
175.0
Atomic weight
Lu
Element symbol
5.43
First ionization potential (eV)

13.90
Second ionization potential (eV)
1663
Melting point (°C)/1 atm

3402
Boiling point (°C)/1 atm

Lutetium

Atomic weight: 174.9668

Chemical form in solution: Lu(OH)x(H2O)y+3-x

Isotope abundance: 175 (97.40%)*; 176 (2.60%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8410 10,000 µg/mL 5% HNO3 100mL CRM
ICP-171 10,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8479 1,000 µg/mL 5% HNO3 100mL CRM
5190-8480 1,000 µg/mL 5% HNO3 500mL CRM
ICP-071 1,000 µg/mL 1% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8573 10 µg/mL 2% HNO3 100mL CRM

Lutetium

89

Ac

89
Atomic number
(227)
Atomic weight
Ac
Element symbol
5.17
First ionization potential (eV)

11.75
Second ionization potential (eV)
1050
Melting point (°C)/1 atm

3200
Boiling point (°C)/1 atm

Actinium

Atomic weight: 227.028

Oxidation states: +3

Actinium

90

Th

90
Atomic number
232.0
Atomic weight
Th
Element symbol
6.31
First ionization potential (eV)

11.90
Second ionization potential (eV)
1750
Melting point (°C)/1 atm

4785
Boiling point (°C)/1 atm

Thorium

Atomic weight: 232.0381

Chemical form in solution: Th(OH)3+ and Th(OH)22+

Isotope abundance: 232 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

AA | MP-AES Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
IAA-290 1,000 µg/mL 4% HNO3 125 mL RM

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-190 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8539 1,000 µg/mL 5% HNO3 100mL CRM
5190-8540 1,000 µg/mL 5% HNO3 500mL CRM
ICP-090 1,000 µg/mL 4% HNO3 125mL RM

Thorium

91

Pa

91
Atomic number
231.0
Atomic weight
Pa
Element symbol
5.89
First ionization potential (eV)
1572
Melting point (°C)/1 atm

4000
Boiling point (°C)/1 atm

Protactinium

Atomic weight: 231.036

Oxidation states: +5, +4, +3

Protactinium

92

U

92
Atomic number
238.0
Atomic weight
U
Element symbol
6.19
First ionization potential (eV)

10.60
Second ionization potential (eV)
1135
Melting point (°C)/1 atm

4131
Boiling point (°C)/1 atm

Uranium

Atomic weight: 238.0289

Chemical form in solution: UO22+ (uranyl)

Isotope abundance: 234 (0.005%); 235 (0.720%); 238 (99.274%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

MP-AES | ICP-OES Standards at 10,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
ICP-192 10,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 1,000 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8549 1,000 µg/mL 5% HNO3 100mL CRM
5190-8550 1,000 µg/mL 5% HNO3 500mL CRM
ICP-092 1,000 µg/mL 4% HNO3 125mL RM

ICP-OES | ICP-MS Standards at 10 and 100 μg/mL

Part Number Concentration Matrix Volume Quality Level (ISO 17034)
5190-8584 10 µg/mL 2% HNO3 100mL CRM

Uranium

93

Np

93
Atomic number
(237)
Atomic weight
Np
Element symbol
6.27
First ionization potential (eV)
644
Melting point (°C)/1 atm

3902
Boiling point (°C)/1 atm

Neptunium

Atomic weight: 237.048

Oxidation states: +7, +6, +5, +4, +3, +2

Neptunium

94

Pu

94
Atomic number
(244)
Atomic weight
Pu
Element symbol
6.03
First ionization potential (eV)

11.20
Second ionization potential (eV)
640
Melting point (°C)/1 atm

3228
Boiling point (°C)/1 atm

Plutonium

Atomic weight: (244)

Oxidation states: (+7), +6, +5, +4, +3, +2

Plutonium

95

Am

95
Atomic number
(243)
Atomic weight
Am
Element symbol
5.97
First ionization potential (eV)
1176
Melting point (°C)/1 atm

2011
Boiling point (°C)/1 atm

Americium

Atomic weight: (243)

Oxidation states: +6, +5, +4, +3, +2

Americium

96

Cm

96
Atomic number
(247)
Atomic weight
Cm
Element symbol
5.99
First ionization potential (eV)
1345
Melting point (°C)/1 atm

Curium

Atomic weight: (247)

Oxidation states: +4, +3, +2

Curium

97

Bk

97
Atomic number
(247)
Atomic weight
Bk
Element symbol
6.20
First ionization potential (eV)
986
Melting point (°C)/1 atm

Berkelium

Atomic weight: (247)

Oxidation states: +4, +3, +2

Berkelium

98

Cf

98
Atomic number
(251)
Atomic weight
Cf
Element symbol
6.28
First ionization potential (eV)

11.80
Second ionization potential (eV)
900
Melting point (°C)/1 atm

Californium

Atomic weight: (251)

Oxidation states: +4, +3, +2

Californium

99

Es

99
Atomic number
(252)
Atomic weight
Es
Element symbol
6.42
First ionization potential (eV)

12.0
Second ionization potential (eV)
860
Melting point (°C)/1 atm

Einsteinium

Atomic weight: (254)

Oxidation states: (+4), +3, (+2)

Einsteinium

100

Fm

100
Atomic number
(257)
Atomic weight
Fm
Element symbol
6.50
First ionization potential (eV)
1527
Melting point (°C)/1 atm

Fermium

Atomic weight: (257)

Oxidation states: +3, (+2)

Fermium

101

Md

101
Atomic number
(258)
Atomic weight
Md
Element symbol
6.58
First ionization potential (eV)
827
Melting point (°C)/1 atm

Mendelevium

Atomic weight: (258)

Oxidation states: +3, +2

Mendelevium

102

No

102
Atomic number
(259)
Atomic weight
No
Element symbol
6.65
First ionization potential (eV)
827
Melting point (°C)/1 atm

Nobelium

Atomic weight: (259)

Oxidation states: +3, +2

Nobelium

103

Lr

103
Atomic number
(262)
Atomic weight
Lr
Element symbol
4.90
First ionization potential (eV)
1627
Melting point (°C)/1 atm

Lawrencium

Atomic weight: (262)

Oxidation states: +3

Lawrencium

サンプル中の重金属やその他の元素の正確な検出は、標準物質と消耗品の品質によって左右されます。アジレントの標準液および認証標準物質はすべて、ISO 17025 および 17034 認証のもとで厳しい検査を受け、製造されています。

相対同位体アバンダンス表をダウンロード

AA マトリックス移動相溶媒

特定の機関のメソッドの混合液およびキットは、こちらをクリックしてください。包括的な標準物質ポートフォリオは、こちらをクリックしてください。

CRM – 認証標準物質 = 測定プロセスを維持またはモニタリングするために使用され、属性値が十分に均一で、安定性があり、十分に確立されている標準物質。一般的にラボ間の試験に使用。

RM – 参照物質 = 1 つ以上の指定された特性に関して十分に均一で安定的であることが検査で確認されており、測定プロセスにおける用途に対し適切であることが確立された標準物質。ISO 17034 の認定を受けた施設で製造されています。

無機標準液

Agilent ULTRA 標準物質カタログ

カタログのダウンロードはこちら

カスタム標準物質

簡単に検索結果を絞り込んだり、化学式を比較したり、価格オプションを検討したり、カスタム標準物質をリクエストしたりできます。(日本では未販売)

ビデオを見る(英語)

最適な分析結果への道筋を照らし出す包括的な無機分析ワークフロー

Bond Elut

元素分析の精度と生産性を高めるには、簡単でコスト効率が高く、分析の目的やメソッドに適したサンプル前処理が必要です。アジレントのソリューションなら、ろ過や精製から固相抽出まで、正確な結果を簡単に得られます。詳しくはこちら

バイアル

分析ワークフローにはバイアルが欠かせません。アジレントのバイアルとキャップを選べば、サンプル容器と分析結果を全面的に信頼できるようになります。詳しくはこちら

標準物質

アジレントは ULTRA Scientific 社と統合しました。これにより、信頼性と有効性に優れた標準物質を幅広く提供できるようになりました。簡単に注文でき、迅速にお届けします。また、カスタム標準もご利用いただけます。詳しくはこちら

トーチ

アジレントの広範な高品質 ICP-OES 消耗品には、ネブライザ、トーチ、アプリケーションキットが含まれています。Agilent 5000 シリーズ ICP-OES 機器用の新しいフルデマンタブルトーチは、インジェクタ部分が着脱可能になったため、トーチのメンテナンスが劇的に簡単になりました。詳しくはこちら

妥協のない AA 性能を確保。アジレントのホローカソードランプは安定性と感度に優れており、検出下限性能を向上させ、長寿命を実現します。詳しくはこちら

OneNeb ネブライザ

アジレントのインタフェースコーンは、Agilent ICP-MS システム用に設計、テストされ、実際のアプリケーションで十分な感度と安定性を発揮します。バックグラウンドが最も低く、質量範囲全般で優れた感度を発揮します。詳細はこちら

Agilent 240 AA

卓越した生産性、精度、信頼性。アジレントは、世界最速のフレーム AA システムなど、あらゆるニーズや予算に合う画期的な AA 機器を取り揃え、業界をリードしています。詳しくはこちら

Agilent 7800 ICP-MS

高速、高感度の元素分析を実現します。Agilent ICP-MS システムにより、精度、使いやすさ、生産性が向上します。詳しくはこちら

5110 ICP-OES

アジレントの高品質 ICP-OES システム、アクセサリー、消耗品、ICP Expert ソフトウェアが、金属分析、元素分析、有機溶媒の調査において、分析の目標達成を支援します。詳しくはこちら

アジレントの充実した機器ラインアップをご覧ください。詳しくはこちら

分析

高品質なソリューションを多数取り揃えたアジレントのラボソフトウェアポートフォリオにより、あらゆる分析システムの性能を最大限に引き出すことができます。詳しくはこちら

メソッドとアプリケーションコンサルティング

新しいメソッドの開発、修理後のメソッドの復元、および新しい機器へのメソッドの移管に時間とコストをかける必要はもうありません。Agilent CrossLab は、サンプル前処理から最終的なレポート作成にいたるワークフローを総合的にサポートします。生産性および利便性を高める最新の機能とサービスを提供し、成果を最大限に高めることができます。詳しくはこちら

CrossLab

アジレントの CrossLab サービスエンジニアは、機器のメーカーにかかわらず、すべての機器のサービスに対応するためのスキル、資格、経験を有しています。詳しくはこちら

時間を短縮し生産性を維持します

シンプルな購入
 

Agilent オンラインストア

時間を節約する、新しい eCommerce 機能をご紹介します。(英語)

詳しくはこちら

カラムや消耗品を簡単に選択できるツール

Agilent フレキシブルスペンドプラン

ツールとガイドで、憶測に頼らず確実に消耗品をお選びいただけます。(英語)

詳しくはこちら

新しい原子分光分析技術情報

トラブルシューティングのヒント、ビデオなどの役立つ情報がすぐに見つかります。

詳しくはこちら