2
Atomic weight: 4.003
Isotope abundance: 4 (100%)
Oxidation states: 0
3
Atomic weight: 6.941
Chemical form in solution: Li+(aq) (large effective radius due to hydration sphere)
Isotope abundance: 6 (7.59%); 7 (92.41%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610103000 | Coded | Lithium (Li) coded single element hollow cathode lamp |
5610124900 | Uncoded | Lithium (Li) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
4
Atomic weight: 9.012
Chemical form in solution: Be2+(H2O)42+
Isotope abundance: 9 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8565 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610100500 | Coded | Beryllium (Be) coded single element hollow cathode lamp |
5610122400 | Uncoded | Beryllium (Be) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
9
Atomic weight: 18.998
Isotope abundance: 19 (100%)
Oxidation states: -1
10
Atomic weight: 20.179
Isotope abundance: 20 (90.48%); 21 (0.27%); 22 (9.25%)
Oxidation states: 0
11
Atomic weight: 22.98977
Chemical form in solution: Na+(H2O)n+
Isotope abundance: 23 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-411 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610105300 | Coded | Sodium (Na) coded single element hollow cathode lamp |
5610127300 | Uncoded | Sodium (Na) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
12
Atomic Weight: 24.305
Chemical form in solution: Mg(H2O)6+2
Isotope abundance: 24 (78.99%)*; 25 (10%); 26 (11.01%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-412 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610103200 | Coded | Magnesium (Mg) coded single element hollow cathode lamp |
5610125100 | Uncoded | Magnesium (Mg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
13
Atomic Weight: 26.98154
Chemical form in solution: Al(H2O)6+3
Isotope abundance: 27 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8561 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610100100 | Coded | Aluminum (Al) coded single element hollow cathode lamp |
5610122000 | Uncoded | Aluminum (Al) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
17
Atomic weight: 35.453
Isotope abundance: 35 (75.76%)*; 37 (24.24%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +6, +5, +4, +3, +1, -1, -2
18
Atomic weight: 39.948
Isotope abundance: 36 (0.34%); 38 (0.06%); 40 (99.60%)
Oxidation states: 0
19
Atomic weight: 39.0983
Chemical form in solution: K+(aq)
Isotope abundance: 39 (93.26%)*; 40 (0.01%); 41 (6.73%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-419 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610104200 | Coded | Potassium (K) coded single element hollow cathode lamp |
5610126200 | Uncoded | Potassium (K) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
20
Atomic weight: 40.078
Chemical form in solution: Ca(H2O)6+2
Isotope abundance: 40 (96.941%); 42 (0.647%); 43 (0.135%)*; 44 (2.086%)*; 46 (0.004%); 48 (0.187%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-420 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610101000 | Coded | Calcium (Ca) coded single element hollow cathode lamp |
5610122900 | Uncoded | Calcium (Ca) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
21
Atomic weight: 44.95591
Chemical form in solution: Sc(H2O)6+2
Isotope abundance: 45 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container. Small atomic radius increases hydrolysis requiring higher acid levels than other Rare Earths.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-221 | 1,000 µg/mL | 5% HNO3 | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610126900 | Uncoded | Scandium (Sc) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
22
Atomic weight: 47.88
Chemical form in solution: Ti(F)6-2
Isotope abundance: 46 (8.25%); 47 (7.44%)*; 48 (73.72%); 49 (5.41%); 50 (5.18%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals) as the Ti(F)6-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Ti(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-422 | 10 µg/mL | 0.5% HNO3 with 0.1% HF | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610106200 | Coded | Titanium (Ti) coded single element hollow cathode lamp |
5610128200 | Uncoded | Titanium (Ti) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
23
Atomic weight: 50.9415
Chemical form in solution: H2V10O284-
Isotope abundance: 50 (0.25%); 51 (99.75%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +5, +4, +3, +2, +1, 0, -1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8585 | 10 µg/mL | 5% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610106500 | Coded | Vanadium (V) coded single element hollow cathode lamp |
5610128500 | Uncoded | Vanadium (V) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
24
Atomic weight: 51.9961
Chemical form in solution: Cr(H2O)63+
Isotope abundance: 50 (4.345%); 52 (83.79%)*; 53 (9.50%); 54 (2.365%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1, -2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610101200 | Coded | Chromium (Cr) coded single element hollow cathode lamp |
5610123100 | Uncoded | Chromium (Cr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
25
Atomic weight: 54.9380
Chemical form in solution: Mn(H2O)62+
Isotope abundance: 55 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8574 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610103300 | Coded | Manganese (Mn) coded single element hollow cathode lamp |
5610125200 | Uncoded | Manganese (Mn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610133700 | High intensity UltrAA | Manganese (Mn) high intensity UltrAA coded single element hollow cathode lamp |
26
Atomic weight: 55.847
Chemical form in solution: Fe(H2O)63+
Isotope abundance: 54 (5.85%); 56 (91.75%)*; 57 (2.12%); 58 (0.28%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2, +1, 0
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-426 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610102700 | Coded | Iron (Fe) coded single element hollow cathode lamp |
5610124600 | Uncoded | Iron (Fe) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610108600 | High intensity UltrAA | Iron (Fe) high intensity UltrAA coded single element hollow cathode lamp |
27
Atomic weight: 58.9332
Chemical form in solution: Co(H2O)62+
Isotope abundance: 59 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +5, +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
8500-6947 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610101300 | Coded | Cobalt (Co) coded single element hollow cathode lamp |
5610123200 | Uncoded | Cobalt (Co) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610134100 | High intensity UltrAA | Cobalt (Co) high intensity UltrAA coded single element hollow cathode lamp |
28
Atomic weight: 58.6934
Chemical form in solution: Ni(H2O)62+
Isotope abundance: 58 (68.08%); 60 (26.22%)*; 61 (1.14%); 62 (3.63%); 64 (0.93%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +4, +3, +2, +1, 0, -1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8576 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610103700 | Coded | Nickel (Ni) coded single element hollow cathode lamp |
5610125600 | Uncoded | Nickel (Ni) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610108500 | High intensity UltrAA | Nickel (Ni) high intensity UltrAA coded single element hollow cathode lamp |
29
Atomic weight: 63.546
Chemical form in solution: Cu(H2O)62+
Isotope abundance: 63 (69.15%)*; 65 (30.85%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8569 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610101400 | Coded | Copper (Cu) coded single element hollow cathode lamp |
5610123300 | Uncoded | Copper (Cu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
30
Atomic weight: 65.38
Chemical form in solution: Zn(OH)(aq)+
Isotope abundance: 64 (49.17%); 66 (27.73%)*; 67 (4.04%); 68 (18.45%); 70 (0.61%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8587 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610106800 | Coded | Zinc (Zn) coded single element hollow cathode lamp |
5610128800 | Uncoded | Zinc (Zn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
31
Atomic weight: 69.723
Chemical form in solution: Ga(H2O)6+3
Isotope abundance: 69 (60.11%); 71 (39.89%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-231 | 1,000 µg/mL | 2% HNO3 | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610123800 | Uncoded | Gallium (Ga) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
35
Atomic weight: 79.904
Isotope abundance: 79 (50.69%)*; 81 (49.31%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +5, +4, +3, +1, -1
36
Atomic weight: 83.8
Isotope abundance: 78 (0.35%); 80 (2.29%); 82 (11.59%); 83 (11.50%); 84 (56.99%); 86 (17.28%)
Oxidation states: +2
37
Atomic weight: 85.4678
Chemical form in solution: Rb+(aq)
Isotope abundance: 85 (72.17%)*; 87 (27.83%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1-1% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8440 | 10,000 µg/mL | 5% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610126600 | Uncoded | Rubidium (Rb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
38
Atomic weight: 87.62
Chemical form in solution: Sr(H2O)6+2
Isotope abundance: 84 (0.56%); 86 (9.86%); 87 (7.00%); 88 (82.58%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8581 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610105400 | Coded | Strontium (Sr) coded single element hollow cathode lamp |
5610127400 | Uncoded | Strontium (Sr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
39
Atomic weight: 88.9059
Chemical form in solution: Y(OH)(H2O)x+2
Isotope abundance: 89 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-239 | 1,000 µg/mL | 5% HNO3 | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610128700 | Uncoded | Yttrium (Y) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
40
Atomic weight: 91.224
Chemical form in solution: Zr(F)6-2
Isotope abundance: 90 (51.45%)*; 91 (11.22%); 92 (17.15%); 94 (17.38%); 96 (2.80%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3, +2, 0, -2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Zr(F)6-2 + Zr(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Zr(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.
Part No. | Type | Description |
---|---|---|
5610106900 | Coded | Zirconium (Zr) coded single element hollow cathode lamp |
5610128900 | Uncoded | Zirconium (Zr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
41
Atomic weight: 92.9064
Chemical form in solution: NbOF5-2
Isotope abundance: 93 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +5, +4, +3, +2, +1, -1, -3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the NbOF5-2 for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the NbOF5-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.
Part No. | Type | Description |
---|---|---|
5610103800 | Coded | Niobium (Nb) coded single element hollow cathode lamp |
5610125700 | Uncoded | Niobium (Nb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
42
Atomic weight: 95.96
Chemical form in solution: MoO4-2 (chem. form as received)
Isotope abundance: 92 (14.53%); 94 (9.15%); 95 (15.84%)*; 96 (16.67%); 97 (9.60%); 98 (24.39%); 100 (9.82%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the MoOF5-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the MoO4-2 chemically stable for years in 1% NH4OH in a LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-442 | 10 µg/mL | 0.5% NH4OH | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610103500 | Coded | Molybdenum (Mo) coded single element hollow cathode lamp |
5610125400 | Uncoded | Molybdenum (Mo) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
43
Atomic weight: (98)
Oxidation states: +7, +6, +5, +4, 0, -1
44
Atomic weight: 101.07
Chemical form in solution: RuCl6
Isotope abundance: 96 (5.54%); 98 (1.87%); 99 (12.76%); 100 (12.60%); 101 (17.06%)*; 102 (31.55%); 104 (18.62%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +8, +7, +6, +5, +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.
Part No. | Type | Description |
---|---|---|
5610126700 | Uncoded | Ruthenium (Ru) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
45
Atomic weight: 102.91
Chemical form in solution: RhCl6-3
Isotope abundance: 103 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-245 | 1,000 µg/mL | 5% HCl | 125 mL | RM |
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
8500-6945 | 10 µg/mL | 2% HCl | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610104500 | Coded | Rhodium (Rh) coded single element hollow cathode lamp |
5610126500 | Uncoded | Rhodium (Rh) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
46
Atomic weight: 106.42
Chemical form in solution: Pd(H2O)62+
Isotope abundance: 102 (1.02%); 104 (11.14%); 105 (22.33%)*; 106 (27.33%); 108 (26.46%); 110 (11.72%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +2, 0
Store at room temperature (15° to 30°C)
2-100 ppb levels. 2 ppb Pd is stable for 1 day in 1% HNO3/LDPE container. 10 ppb is stable for 3 days in 1% HNO3/LDPE container. 100 ppb is stable for ≥ 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610104000 | Coded | Palladium (Pd) coded single element hollow cathode lamp |
5610125900 | Uncoded | Palladium (Pd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610135800 | High intensity UltrAA | Palladium (Pd) high intensity UltrAA coded single element hollow cathode lamp |
47
Atomic weight: 107.8682
Chemical form in solution: Ag(H2O)6+
Isotope abundance: 107 (51.84%)*; 109 (48.16%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for 75+ days when mixed with equivalent levels of all other elements including the precious metals (where chloride is present) when in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8580 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610105200 | Coded | Silver (Ag) coded single element hollow cathode lamp |
5610127200 | Uncoded | Silver (Ag) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
48
Atomic weight: 112.41
Chemical form in solution: Cd2(OH)(aq)3+ and Cd(OH)(aq)+
Isotope abundance: 106 (1.25%); 108 (0.89%); 110 (12.49%); 111 (12.80%)*; 112 (24.13%); 113 (12.22%); 114 (28.73%); 116 (7.49%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8567 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610100800 | Coded | Cadmium (Cd) coded single element hollow cathode lamp |
5610122700 | Uncoded | Cadmium (Cd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
49
Atomic weight: 114.82
Chemical form in solution: In(H2O)6+3
Isotope abundance: 113 (4.29%); 115 (95.71%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8284 | 1,000 µg/mL | 5% HNO3 | 100 mL | CRM |
Part No. | Type | Description |
---|---|---|
5610124400 | Uncoded | Indium (In) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
50
Atomic weight: 118.710
Chemical form in solution: Sn(OH)xFy2-
Isotope abundance: 112 (0.97%); 114 (0.66%); 115 (0.34%); 116 (14.54%); 117 (7.68%); 118 (24.22%)*; 119 (8.59%); 120 (32.58%); 122 (4.63%); 124 (5.79%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Sn(OH)xFy2- for 1 year in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Sn(OH)xFy2- are chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8583 | 10 µg/mL | 5% HCl | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610106100 | Coded | Tin (Sn) coded single element hollow cathode lamp |
5610128100 | Uncoded | Tin (Sn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610133900 | High intensity UltrAA | Tin (Sn) high intensity UltrAA coded single element hollow cathode lamp |
53
Atomic weight: 126.905
Isotope abundance: 127 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +5, +3, +1, 0, -1
54
Atomic weight: 131.29
Isotope abundance: 124 (0.09%); 126 (0.09%); 128 (1.92%); 129 (26.40%); 130 (4.07%); 131 (21.23%); 132 (26.91%); 134 (10.44%); 136 (8.86%)
Oxidation states: +8, +6, +4, +2
55
Atomic weight: 132.9054
Chemical form in solution: Cs+(aq)
Isotope abundance: 133 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1% HNO3/LDPE container. Will crystallize out of higher (~ 5%) levels of HNO3 at > 1000 µg/mL.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8274 | 1,000 µg/mL | 5% HNO3 | 100 mL | CRM |
1,000 µg/mL | 2% HNO3 | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610122800 | Uncoded | Cesium (Cs) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
56
Atomic weight: 137.33
Chemical form in solution: Ba(H2O)6+2
Isotope abundance: 130 (0.11%); 132 (0.10%); 134 (2.42%); 135 (6.59%); 136 (7.85%); 137 (11.23%)*; 138 (71.70%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8564 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610100400 | Coded | Barium (Ba) coded single element hollow cathode lamp |
5610122300 | Uncoded | Barium (Ba) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
72
Atomic weight: 178.49
Chemical form in solution: Hf(F)6-2
Isotope abundance: 174 (0.16%); 176 (5.26%); 177 (18.60%); 178 (27.28%)*; 179 (13.62%); 180 (35.08%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable alone or mixed with all other metals that are at comparable levels as the Hf(F)6-2 + Hf(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Hf(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-172 | 10,000 µg/mL | 0.2% HF | 125mL | RM |
Part No. | Type | Description |
---|---|---|
5610102200 | Coded | Hafnium (Hf) coded single element hollow cathode lamp |
5610124100 | Uncoded | Hafnium (Hf) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
73
Atomic weight: 180.9479
Chemical form in solution: TaOF6-3
Isotope abundance: 180 (0.01%); 181 (99.99%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +5, +4, +3, +1, -1, -3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the TaOF6-3, for 2 months at the 2-10 ppb level in 1% HNO3/LDPE container and for 5 months at the 100 ppb level under same conditions. 1-10,000 ppm single element solutions as the TaOF6-3 are chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.
Part No. | Type | Description |
---|---|---|
5610105500 | Coded | Tantalum (Ta) coded single element hollow cathode lamp |
5610127500 | Uncoded | Tantalum (Ta) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
74
Atomic weight: 183.85
Chemical form in solution: WOF5-2 (chem. form as received)
Isotope abundance: 180 (0.12%); 182 (26.50%)*; 183 (14.31%); 184 (30.64%); 186 (28.43%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2, 0, -1, -2, -4
Store at room temperature (15° to 30°C)
2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the [WOF5]-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the [WOF5]-2 chemically stable for years in 1% HF in a LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-274 | 1,000 µg/mL | 0.5% NH4OH | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610128300 | Uncoded | Tungsten (W) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
75
Atomic weight: 186.207
Chemical form in solution: ReO4-
Isotope abundance: 185 (37.40%)*; 187 (62.60%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1, -3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610104400 | Coded | Rhenium (Re) coded single element hollow cathode lamp |
5610126400 | Uncoded | Rhenium (Re) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
76
Atomic weight: 190.2
Chemical form in solution: OsCl62-
Isotope abundance: 184 (0.02%); 186 (1.59%); 187 (1.96%); 188 (13.24%); 189 (16.15%)*; 190 (26.26%); 192 (40.78%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +8, +7, +6, +5, +4, +3, +2, +1, 0, -2
77
Atomic weight: 192.22
Chemical form in solution: IrCl6-2
Isotope abundance: 191 (37.3%); 193 (62.7%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3, +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels. 2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-277 | 1,000 µg/mL | 5% HCl | 125 mL | RM |
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8570 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610102600 | Coded | Iridium (Ir) coded single element hollow cathode lamp |
5610124500 | Uncoded | Iridium (Ir) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
78
Atomic weight: 195.08
Chemical form in solution: Pt(Cl)62-
Isotope abundance: 190 (0.012%); 192 (0.782%); 194 (32.86%); 195 (33.78%)*; 196 (25.21%); 198 (7.356%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +2, 0
Store at room temperature (15° to 30°C)
2-10 ppb Pt is stable for 2 months in 1% HNO3/LDPE container. 100 ppb is stable for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8577 | 10 µg/mL | 5% HCl | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610104100 | Coded | Platinum (Pt) coded single element hollow cathode lamp |
5610126100 | Uncoded | Platinum (Pt) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610135900 | High intensity UltrAA | Platinum (Pt) high intensity UltrAA coded single element hollow cathode lamp |
79
Atomic weight: 196.9665
Chemical form in solution: Au(Cl)63-
Isotope abundance: 197 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +7, +5, +3, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels. 2-10 ppb Au is stable for ≤ 1 day maximum in 1% HNO3/LDPE container. 100 ppb is stable for ≤ 2 days maximum in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
8500-7000 | 100 µg/mL | 2% HCl | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610102100 | Coded | Gold (Au) coded single element hollow cathode lamp |
5610124000 | Uncoded | Gold (Au) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610109000 | High intensity UltrAA | Gold (Au) high intensity UltrAA coded single element hollow cathode lamp |
80
Atomic weight: 200.59
Chemical form in solution: Hg(OH)(aq)+
Isotope abundance: 196 (0.15%); 198 (9.97%); 199 (16.87%); 200 (23.10%); 201 (13.18%)*; 202 (29.86%)*; 204 (6.87%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +2, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels—stable in 10% HNO3 packaged in borosilicate glass; NOT stable in 1% HNO3/ LDPE container. 1-100 ppm levels stable in 7% HNO3 packaged in borosilicate glass. 1000-10,000 ppm solutions are chemically stable for years in 5-10% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8575 | 10 µg/mL | 5% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610103400 | Coded | Mercury (Hg) coded single element hollow cathode lamp |
5610125300 | Uncoded | Mercury (Hg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
81
Atomic weight: 204.383
Chemical form in solution: Tl(H2O)6+
Isotope abundance: 203 (29.52%); 205 (70.48%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +1
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-481 | 10 µg/mL | 0.5% HNO3 | 125mL | CRM |
Part No. | Type | Description |
---|---|---|
5610105800 | Coded | Thallium (Tl) coded single element hollow cathode lamp |
5610127800 | Uncoded | Thallium (Tl) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610108400 | High intensity UltrAA | Thallium (Tl) high intensity UltrAA coded single element hollow cathode lamp |
82
Atomic weight: 207.2
Chemical form in solution: Pb(H2O)6+2
Isotope abundance: 204 (1.4%); 206 (24.1%); 207 (22.1%); 208 (52.4%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8571 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610102900 | Coded | Lead (Pb) coded single element hollow cathode lamp |
5610124800 | Uncoded | Lead (Pb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610108200 | High intensity UltrAA | Lead (Pb) high intensity UltrAA coded single element hollow cathode lamp |
83
Atomic weight: 208.9804
Chemical form in solution: Bi(O)(H2O)x+
Isotope abundance: 209 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +5, +3, +1, -3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-7% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610100600 | Coded | Bismuth (Bi) coded single element hollow cathode lamp |
5610122500 | Uncoded | Bismuth (Bi) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
5610134200 | High intensity UltrAA | Bismuth (Bi) high intensity UltrAA coded single element hollow cathode lamp |
85
Atomic weight: (210)
Oxidation states: +3, +1, -1
86
Atomic weight: (222)
Oxidation states: +2
87
Atomic weight: (223)
Oxidation states: +1
88
Atomic weight: 226.025
Oxidation states: +2
104
Atomic weight: (267)
105
Atomic weight: (268)
106
Atomic weight: (269)
107
Atomic weight: (270)
108
Atomic weight: (277)
109
Atomic weight: (278)
110
Atomic weight: (281)
111
Atomic weight: (282)
112
Atomic weight: (285)
113
Atomic weight: (284)
114
Atomic weight: (289)
115
Atomic weight: (288)
116
Atomic weight: (293)
117
Atomic weight: (294)
118
Atomic weight: (294)
57
Atomic weight: 138.9055
Chemical form in solution: La(OH)y(H2O)x+3-y
Isotope abundance: 138 (0.09%); 139 (99.91%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-257 | 1,000 µg/mL | 1% HNO3 | 125 mL | RM |
Part No. | Type | Description |
---|---|---|
5610124700 | Uncoded | Lanthanum (La) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
58
Atomic weight: 140.12
Chemical form in solution: Ce(OH)y(H2O)x+4-y
Isotope abundance: 136 (0.19%); 138 (0.25%); 140 (88.45%)*; 142 (11.11%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-258 | 1,000 µg/mL | 2% HNO3 | 125 mL | RM |
59
Atomic weight: 140.9077
Chemical form in solution: Pr(OH)y(H2O)x+3-y
Isotope abundance: 141 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-259 | 1,000 µg/mL | 1% HNO3 | 125 mL | RM |
60
Atomic weight: 144.24
Chemical form in solution: Nd(OH)y(H2O)x+3-y
Isotope abundance: 142 (27.2%); 143 (12.2%); 144 (23.8%); 145 (8.3%); 146 (17.2%)*; 148 (5.7%); 150 (5.6%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610103600 | Coded | Neodymium (Nd) coded single element hollow cathode lamp |
5610125500 | Uncoded | Neodymium (Nd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
61
Atomic weight: (145)
Oxidation states: +3
62
Atomic weight: 150.36
Chemical form in solution: Sm(OH)y(H2O)x+3-y
Isotope abundance: 144 (3.07%); 147 (14.99%)*; 148 (11.24%); 149 (13.82%); 150 (7.38%); 152 (26.75%); 154 (22.75%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8515 | 1,000 µg/mL | 5% HNO3 | 100mL | CRM |
Part No. | Type | Description |
---|---|---|
5610126800 | Uncoded | Samarium (Sa) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
63
Atomic weight: 151.96
Chemical form in solution: Eu(OH)y(H2O)x+3-y
Isotope abundance: 151 (47.81%); 153 (52.19%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610123600 | Uncoded | Europium (Eu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
64
Atomic weight: 157.25
Chemical form in solution: Gd(OH)x(H2O)y+3-x
Isotope abundance: 152 (0.2%); 154 (2.18%); 155 (14.80%); 156 (20.47%); 157 (15.65%)*; 158 (24.84%); 160 (21.86%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part No. | Type | Description |
---|---|---|
5610123700 | Uncoded | Gadolinium (Gd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector |
65
Atomic weight: 158.9254
Chemical form in solution: Tb(OH)x(H2O)y+3-x
Isotope abundance: 159 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8216 | 10,000 µg/mL | 500mL | CRM |
66
Atomic weight: 162.50
Chemical form in solution: Dy(OH)x(H2O)y+3-x
Isotope abundance: 156 (0.06%); 158 (0.09%); 160 (2.33%); 161 (18.89%); 162 (25.47%); 163 (24.90%)*; 164 (28.26%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
67
Atomic weight: 164.9304
Chemical form in solution: Ho(OH)x(H2O)y+3-x
Isotope abundance: 165 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
68
Atomic weight: 167.26
Chemical form in solution: Er(OH)x(H2O)y+3-x
Isotope abundance: 162 (0.14%); 164 (1.60%); 166 (33.50%)*; 167 (22.87%); 168 (26.98%); 170 (14.91%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
69
Atomic weight: 168.9342
Chemical form in solution: Tm(OH)x(H2O)y+3-x
Isotope abundance: 169 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
70
Atomic weight: 173.054
Chemical form in solution: Yb(OH)x(H2O)y+3-x
Isotope abundance: 168 (0.12%); 170 (2.98%); 171 (14.09%); 172 (21.68%)*; 173 (16.10%); 174 (32.03%); 176 (13.00%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
71
Atomic weight: 174.9668
Chemical form in solution: Lu(OH)x(H2O)y+3-x
Isotope abundance: 175 (97.40%)*; 176 (2.60%)
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8573 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
89
Atomic weight: 227.028
Oxidation states: +3
90
Atomic weight: 232.0381
Chemical form in solution: Th(OH)3+ and Th(OH)22+
Isotope abundance: 232 (100%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +4, +3, +2
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
IAA-290 | 1,000 µg/mL | 4% HNO3 | 125 mL | RM |
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-190 | 10,000 µg/mL | 4% HNO3 | 125mL | RM |
91
Atomic weight: 231.036
Oxidation states: +5, +4, +3
92
Atomic weight: 238.0289
Chemical form in solution: UO22+ (uranyl)
Isotope abundance: 234 (0.005%); 235 (0.720%); 238 (99.274%)*
Highlighted isotope is the recommended mass number for ICP-MS analysis
Oxidation states: +6, +5, +4, +3
Store at room temperature (15° to 30°C)
2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
ICP-192 | 10,000 µg/mL | 4% HNO3 | 125mL | RM |
Part Number | Concentration | Matrix | Volume | Quality Level (ISO 17034) |
---|---|---|---|---|
5190-8584 | 10 µg/mL | 2% HNO3 | 100mL | CRM |
93
Atomic weight: 237.048
Oxidation states: +7, +6, +5, +4, +3, +2
94
Atomic weight: (244)
Oxidation states: (+7), +6, +5, +4, +3, +2
95
Atomic weight: (243)
Oxidation states: +6, +5, +4, +3, +2
96
Atomic weight: (247)
Oxidation states: +4, +3, +2
97
Atomic weight: (247)
Oxidation states: +4, +3, +2
98
Atomic weight: (251)
Oxidation states: +4, +3, +2
99
Atomic weight: (254)
Oxidation states: (+4), +3, (+2)
100
Atomic weight: (257)
Oxidation states: +3, (+2)
101
Atomic weight: (258)
Oxidation states: +3, +2
102
Atomic weight: (259)
Oxidation states: +3, +2
103
Atomic weight: (262)
Oxidation states: +3
Accurately detecting heavy metals and other elements in your samples relies on the quality of your chemical standards and supplies. All Agilent reference and certified reference materials are rigorously tested and manufactured using ISO 17025 and 17034 accreditations.
Download a printable copy with a full relative isotopic abundance table.
For specific agency method mixes and kits, please click here. And click here to view our full chemical standards portfolio.
CRM – Certified Reference Material = A standards whose property values are sufficiently homogeneous, stable and well established to be used for maintaining or monitoring measurement processes. Typically used for inter-laboratory testing.
RM – Reference Materials = Standards that have been tested to be sufficiently homogeneous and stable with respect to one or more specified properties, which has been established to be fit for its intended use in a measurement process. Standards are manufactured in ISO 17034 accredited facility.
Accurate, productive elemental analysis demands sample preparation that is straightforward, cost effective, and compatible with your analytical goals and methods. From filtration and purification to solid phase extraction, Agilent makes delivering accurate results easier. Learn more
Vials are a critical part of your analytical workflow. Choose Agilent vials and closures and gain complete confidence in your sample containment—and your results. Learn more
ULTRA Scientific has been acquired by Agilent. That means we can now offer you a full portfolio of reliable and effective reference materials, along with easy online ordering, rapid shipping, and custom solutions. Learn more
Agilent’s range of high-quality ICP-OES supplies includes nebulizers, torches and application kits. The fully demountable torch for the Agilent 5000 Series ICP-OES instruments features a removable injector to simplify torch maintenance and allows quick changeover for diverse sample matrices. Learn more
Never compromise on AA performance. Agilent hollow cathode lamps deliver excellent stability and sensitivity, improved detection limit performance, and a longer service life. Learn more
Agilent interface cones are designed and tested on Agilent ICP-MS systems to ensure sensitivity and stability with real-world applications. They offer superior sensitivity across the mass range with the lowest background.Learn more
Productive, precise, and reliable. Agilent leads the industry with innovative AA instruments to match every need and budget—including the world’s fastest flame AA system. Learn more
Perform fast, sensitive elemental analysis. Agilent ICP-MS systems give you excellent accuracy, ease of use, and productivity. Learn more
Whether for metals analysis, elemental analysis or investigation of organic solvents, our high-quality ICP-OES systems, accessories, supplies, and ICP Expert software can help you reach your analytical goals. Learn more
See our entire portfolio of instruments. Learn more
Our lab software portfolio features a range of high-quality solutions to ensure your laboratory can make the most of every analytical system. Learn more
Avoid the time and costs of developing new methods from scratch, restoring methods after a repair, and transitioning methods to new instruments. Agilent CrossLab application support can help you confidently deploy the latest productivity and usability enhancements and ensure the best outcomes—from sample preparation to final report. Learn more
Agilent CrossLab service engineers have the skills, qualifications, and experience to manage all your instrument servicing, regardless of the manufacturer. Learn more