Find All Your Single-Element Supplies with Our Interactive Periodic Table

chemical standards

Easily find high-quality standards to comply with EPA 200.8 regulations

Accurately detecting heavy metals and other elements in environmental, food, and elemental analysis samples depends on having high-quality reference materials. Agilent ULTRA standards are rigorously tested and manufactured using ISO 17025 and 17034 accreditations.

To read a full description—plus ordering information—simply click the element you’re looking for.

  • Solid (g/cm3, 20 °C)
  • Liquid (g/mL, 20 °C)
  • Gas (g/L, 0 °C, 1 atm)
  • Artificially created
  • Single-element standards available from Agilent
  • Not commercially available
1
IA
2
IIA
3
IIIB
4
IVB
5
VB
6
VIB
7
VIIB
8
9
VIII
10
11
IB
12
IIB
13
IIIA
14
IVA
15
VA
16
VIA
17
VIIA
18
VIIIA

1

H

1
1.008
H
13.60
-259
-253

Hydrogen

Atomic weight: 1.008

Isotope abundance: 1 (99.99%); 2 (0.01%)

Oxidation states: +1, 0, -1

2

He

2
4.003
He
24.59
54.42
-269

Helium

Atomic weight: 4.003

Isotope abundance: 4 (100%)

Oxidation states: 0

3

Li

3
6.94
Li
5.39
75.64
181
1342

Lithium

Atomic weight: 6.941

Chemical form in solution: Li+(aq) (large effective radius due to hydration sphere)

Isotope abundance: 6 (7.59%); 7 (92.41%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-403 10 µg/mL Water with dilute nitric acid 125 mL
ICP-303 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-103 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-003 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-003-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-103-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-003 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8589 10 µg/mL 2% HNO3 100 mL
5190-8760 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8761 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8572 10 µg/mL 2% HNO3 100 mL
5190-8408 10,000 µg/mL 5% HNO3 100 mL
5190-8409 10,000 µg/mL 5% HNO3 500 mL
5190-8289 1,000 µg/mL 5% HNO3 100 mL
5190-8477 1,000 µg/mL 5% HNO3 100 mL
5190-8290 1,000 µg/mL 5% HNO3 500 mL
5190-8478 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103000 Coded Lithium (Li) coded single element hollow cathode lamp
5610124900 Uncoded Lithium (Li) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

4

Be

4
9.012
Be
9.32
18.21
1287
2468

Beryllium

Atomic weight: 9.012

Chemical form in solution: Be2+(H2O)42+

Isotope abundance: 9 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-404 10 µg/mL Water with dilute nitric acid 125 mL
ICP-104 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-004 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-004-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-004 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8738 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8565 10 µg/mL 2% HNO3 100 mL
5190-8360 10,000 µg/mL 5% HNO3 100 mL
5190-8361 10,000 µg/mL 5% HNO3 500 mL
5190-8250 1,000 µg/mL 5% HNO3 100 mL
5190-8264 1,000 µg/mL 5% HNO3 100 mL
5190-8251 1,000 µg/mL 5% HNO3 500 mL
5190-8265 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610100500 Coded Beryllium (Be) coded single element hollow cathode lamp
5610122400 Uncoded Beryllium (Be) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

5

B

5
10.81
B
8.30
25.15
2077
4000

Boron

Atomic weight: 10.811

Chemical form in solution: B(OH)3 and B(OH)4-

Isotope abundance: 10 (19.9%); 11 (80.1%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-1,000 ppm solutions chemically stable for years in 1% HNO3/LDPE container. 1000-10,000 ppm stable for years in dilute NH4OH/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-405 10 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-305 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-105 10,000 µg/mL Water with dilute ammonium hydroxide 125 mL
IAA-005 10,000 µg/mL Water with dilute ammonium hydroxide 10 mL
IAA-205 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
5190-8740 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8741 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8566 10 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8364 10,000 µg/mL 1% NH4OH 100 mL
5190-8365 10,000 µg/mL 1% NH4OH 500 mL
5190-8254 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8268 1,000 µg/mL 5% HNO3 100 mL
5190-8269 1,000 µg/mL 5% HNO3 500 mL
5190-8255 1,000 µg/mL water (low TOC, < 50 ppb) 500 mL

Single element lamps

Part No. Type Description
5610100700 Coded Boron (B) coded single element hollow cathode lamp
5610122600 Uncoded Boron (B) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135700 High intensity UltrAA Boron (B) high intensity UltrAA coded single element hollow cathode lamp

6

C

6
12.01
C
11.26
24.38
3825
3825

Carbon

Atomic weight: 12.011

Chemical form in solution: (Carbon standard is made using Tartaric Acid)

Isotope abundance: 12 (98.93%); 13 (1.07%)

Oxidation states: +4, +2, -4

7

N

7
14.01
N
14.53
29.60
-210
-196

Nitrogen

Atomic weight: 14.007

Isotope abundance: 14 (99.64%); 15 (0.36%)

Oxidation states: +5, +4, +3, +2, -1, -2, -3

8

O

8
16.00
O
13.62
35.12
-219
-183

Oxygen

Atomic weight: 15.999

Isotope abundance: 16 (99.76%); 17 (0.04%); 18 (0.2%)

Oxidation states: +2, +1, 0, -1, -2

9

F

9
19.00
F
17.42
34.97
-220
-188

Fluorine

Atomic weight: 18.998

Isotope abundance: 19 (100%)

Oxidation states: -1

10

Ne

10
20.18
Ne
21.56
40.96
-249
-246

Neon

Atomic weight: 20.179

Isotope abundance: 20 (90.48%); 21 (0.27%); 22 (9.25%)

Oxidation states: 0

11

Na

11
22.99
Na
5.14
47.29
98
883

Sodium

Atomic weight: 22.98977

Chemical form in solution: Na+(H2O)n+

Isotope abundance: 23 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-411 10 µg/mL Water with dilute nitric acid 125 mL
ICP-311 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-011 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-111 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-011-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-011 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-211 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8781 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8782 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8454 10,000 µg/mL 5% HNO3 100 mL
5190-8206 10,000 µg/mL 5% HNO3 500 mL
5190-8311 1,000 µg/mL 5% HNO3 100 mL
5190-8525 1,000 µg/mL 5% HNO3 100 mL
5190-8312 1,000 µg/mL 5% HNO3 500 mL
5190-8526 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610105300 Coded Sodium (Na) coded single element hollow cathode lamp
5610127300 Uncoded Sodium (Na) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

12

Mg

12
24.31
Mg
7.65
15.04
650
1090

Magnesium

Atomic Weight: 24.305

Chemical form in solution: Mg(H2O)6+2

Isotope abundance: 24 (78.99%)*; 25 (10%); 26 (11.01%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-412 10 µg/mL Water with dilute nitric acid 125 mL
ICP-312 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-012 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-112 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-012-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-112-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-012 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-212 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8762 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8763 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8412 10,000 µg/mL 5% HNO3 100 mL
5190-8413 10,000 µg/mL 5% HNO3 500 mL
5190-8291 1,000 µg/mL 5% HNO3 100 mL
5190-8481 1,000 µg/mL 5% HNO3 100 mL
5190-8292 1,000 µg/mL 5% HNO3 500 mL
5190-8482 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103200 Coded Magnesium (Mg) coded single element hollow cathode lamp
5610125100 Uncoded Magnesium (Mg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

13

Al

13
26.98
Al
5.99
18.83
660
2519

Aluminum

Atomic Weight: 26.98154

Chemical form in solution: Al(H2O)6+3

Isotope abundance: 27 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-313 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-013 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-113 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-013-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-113-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-013 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8561 10 µg/mL 2% HNO3 100 mL
5190-8352 10,000 µg/mL 5% HNO3 100 mL
5190-8353 10,000 µg/mL 5% HNO3 500 mL
5190-8731 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8242 1,000 µg/mL 5% HNO3 100 mL
5190-8732 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8256 1,000 µg/mL 5% HCl 100 mL
5190-8243 1,000 µg/mL 5% HNO3 500 mL
5190-8257 1,000 µg/mL 5% HCl 500 mL

Single element lamps

Part No. Type Description
5610100100 Coded Aluminum (Al) coded single element hollow cathode lamp
5610122000 Uncoded Aluminum (Al) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

14

Si

14
28.09
Si
8.15
16.35
1414
3265

Silicon

Atomic Weight: 28.0855

Chemical form in solution: Si(OH)x(F)y2-

Isotope abundance: 28 (92.22%)*; 29 (4.69%); 30 (3.09%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—(alone or mixed with all other metals) as the Si(OH)x(F)y2-. 1-10,000 ppm single element solutions as the Si(OH)x(F)y2- chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • H2O at pH 7
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-414 10 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-314 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-114 10,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-014 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-014-25 1,000 µg/mL Water with dilute nitric and trace HF acids 25 mL
IAA-014 10,000 µg/mL Water with dilute nitric and trace HF acids 10 mL
IAA-214 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
5190-8777 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8778 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8450 10,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8451 10,000 µg/mL water (low TOC, < 50 ppb) 500 mL
5190-8308 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8521 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8522 1,000 µg/mL water (low TOC, < 50 ppb) 500 mL

Single element lamps

Part No. Type Description
5610105100 Coded Silicon (Si) coded single element hollow cathode lamp
5610127100 Uncoded Silicon (Si) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133400 High intensity UltrAA Silicon (Si) high intensity UltrAA coded single element hollow cathode lamp

15

P

15
30.97
P
10.49
19.77
44
281

Phosphorus

Atomic weight: 30.97376

Chemical form in solution: OP(OH)2(O)-

Isotope abundance: 31 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, +2, +1, -2, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0-1% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-415 10 µg/mL Water with dilute nitric acid 125 mL
ICP-315 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-115 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-015 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-015-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-215 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8771 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8772 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8428 10,000 µg/mL 5% HNO3 100 mL
5190-8429 10,000 µg/mL 5% HNO3 500 mL
5190-8499 1,000 µg/mL 5% HNO3 100 mL
5190-8500 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610107700 Coded Phosphorus (P) coded single element hollow cathode lamp
5610126000 Uncoded Phosphorus (P) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

16

S

16
32.06
S
10.36
23.34
115
445

Sulfur

Atomic weight: 32.066

Chemical form in solution: (O)2S(OH)2

Isotope abundance: 32 (94.99%); 33 (0.75%); 34 (4.25%)*; 36 (0.01%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-416 10 µg/mL Water (low TOC, < 50 ppb) 125 mL
ICP-316 1,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
ICP-016 1,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
ICP-116 10,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
IAA-016 10,000 µg/mL Water (low TOC, < 50 ppb) 10 mL
IAA-216 1,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
5190-8784 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8785 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8729 100 µg/g B100 Biodiesel 100 mL
5190-8724 10 µg/g B100 Biodiesel 100 mL
5190-8725 15 µg/g B100 Biodiesel 100 mL
5190-8726 20 µg/g B100 Biodiesel 100 mL
5190-8727 25 µg/g B100 Biodiesel 100 mL
5190-8730 500 µg/g B100 Biodiesel 100 mL
5190-8728 50 µg/g B100 Biodiesel 100 mL
5190-8209 10,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8210 10,000 µg/mL water (low TOC, < 50 ppb) 500 mL
5190-8529 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8530 1,000 µg/mL water (low TOC, < 50 ppb) 500 mL

17

Cl

17
35.45
Cl
12.97
23.81
-102
-34

Chlorine

Atomic weight: 35.453

Isotope abundance: 35 (75.76%)*; 37 (24.24%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +1, -1, -2

18

Ar

18
39.95
Ar
15.76
27.63
-189
-186

Argon

Atomic weight: 39.948

Isotope abundance: 36 (0.34%); 38 (0.06%); 40 (99.60%)

Oxidation states: 0

19

K

19
39.10
K
4.34
31.63
64
759

Potassium

Atomic weight: 39.0983

Chemical form in solution: K+(aq)

Isotope abundance: 39 (93.26%)*; 40 (0.01%); 41 (6.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-419 10 µg/mL Water with dilute nitric acid 125 mL
ICP-319 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-019 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-119 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-019-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-119-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-019 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-219 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8773 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8774 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8432 10,000 µg/mL 5% HNO3 100 mL
5190-8433 10,000 µg/mL 5% HNO3 500 mL
5190-8304 1,000 µg/mL 5% HNO3 100 mL
5190-8503 1,000 µg/mL 5% HNO3 100 mL
5190-8305 1,000 µg/mL 5% HNO3 500 mL
5190-8504 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610104200 Coded Potassium (K) coded single element hollow cathode lamp
5610126200 Uncoded Potassium (K) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

20

Ca

20
40.08
Ca
6.11
11.87
842
1484

Calcium

Atomic weight: 40.078

Chemical form in solution: Ca(H2O)6+2

Isotope abundance: 40 (96.941%); 42 (0.647%); 43 (0.135%)*; 44 (2.086%)*; 46 (0.004%); 48 (0.187%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-420 10 µg/mL Water with dilute nitric acid 125 mL
ICP-320 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-020 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-120 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-020-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-120-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-020 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-220 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8744 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8745 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8369 10,000 µg/mL 5% HNO3 500 mL
5190-8368 10,000 µg/mL 5% HNO3 100 mL
5190-8329 1,000 µg/mL 5% HNO3 100 mL
5190-8272 1,000 µg/mL 5% HNO3 100 mL
5190-8330 1,000 µg/mL 5% HNO3 500 mL
5190-8273 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610101000 Coded Calcium (Ca) coded single element hollow cathode lamp
5610122900 Uncoded Calcium (Ca) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

21

Sc

21
44.96
Sc
6.56
12.80
1541
2836

Scandium

Atomic weight: 44.95591

Chemical form in solution: Sc(H2O)6+2

Isotope abundance: 45 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-10% HNO3/LDPE container. Small atomic radius increases hydrolysis requiring higher acid levels than other Rare Earths.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-121 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-021 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-021-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-221 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8775 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8578 10 µg/mL 2% HNO3 100 mL
5190-8446 10,000 µg/mL 5% HNO3 100 mL
5190-8447 10,000 µg/mL 5% HNO3 500 mL
5190-8517 1,000 µg/mL 5% HNO3 100 mL
5190-8518 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610126900 Uncoded Scandium (Sc) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

22

Ti

22
47.87
Ti
6.83
13.58
1670
3287

Titanium

Atomic weight: 47.88

Chemical form in solution: Ti(F)6-2

Isotope abundance: 46 (8.25%); 47 (7.44%)*; 48 (73.72%); 49 (5.41%); 50 (5.18%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals) as the Ti(F)6-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Ti(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-322 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-422 10 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-122 10,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-022 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-022-25 1,000 µg/mL Water with dilute nitric and trace HF acids 25 mL
IAA-022 10,000 µg/mL Water with dilute nitric and trace HF acids 10 mL
IAA-222 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
5190-8789 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8790 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8224 10,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8225 10,000 µg/mL water (low TOC, < 50 ppb) 500 mL
5190-8320 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8545 1,000 µg/mL water (low TOC, < 50 ppb) 100 mL
5190-8321 1,000 µg/mL water (low TOC, < 50 ppb) 500 mL
5190-8546 1,000 µg/mL water (low TOC, < 50 ppb) 500 mL

Single element lamps

Part No. Type Description
5610106200 Coded Titanium (Ti) coded single element hollow cathode lamp
5610128200 Uncoded Titanium (Ti) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

23

V

23
50.94
V
6.75
14.62
1910
3407

Vanadium

Atomic weight: 50.9415

Chemical form in solution: H2V10O284-

Isotope abundance: 50 (0.25%); 51 (99.75%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-423 10 µg/mL Water with trace nitric acid 125 mL
ICP-323 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-123 10,000 µg/mL Water with dilute nitric acid and 2% HF acids 125 mL
ICP-023 1,000 µg/mL Water with dilute nitric acid and trace hydrofluoric acid 125 mL
ICP-023-25 1,000 µg/mL Water with dilute nitric acid and trace hydrofluoric acid 25 mL
ICP-123-25 10,000 µg/mL Water with dilute nitric acid and trace hydrofluoric acid 25 mL
IAA-023 10,000 µg/mL Water with dilute nitric and hydrofluoric acids 10 mL
IAA-223 1,000 µg/mL Water with dilute nitric acid and trace hydrofluoric acid 125 mL
5190-8585 10 µg/mL 5% HNO3 100 mL
5190-8793 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8794 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8228 10,000 µg/mL 5% HNO3 100 mL
5190-8229 10,000 µg/mL 5% HNO3 500 mL
5190-8323 1,000 µg/mL 5% HNO3 100 mL
5190-8551 1,000 µg/mL 5% HNO3 100 mL
5190-8324 1,000 µg/mL 5% HNO3 500 mL
5190-8552 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610106500 Coded Vanadium (V) coded single element hollow cathode lamp
5610128500 Uncoded Vanadium (V) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

24

Cr

24
52.00
Cr
6.77
16.49
1907
2671

Chromium

Atomic weight: 51.9961

Chemical form in solution: Cr(H2O)63+

Isotope abundance: 50 (4.345%); 52 (83.79%)*; 53 (9.50%); 54 (2.365%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-324 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-124 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-024 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-024-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-124-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-024 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-224 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8748 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8749 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8568 10 µg/mL 2% HNO3 100 mL
5190-8374 10,000 µg/mL 5% HNO3 100 mL
5190-8375 10,000 µg/mL 5% HNO3 500 mL
5190-8344 1,000 µg/mL 5% HNO3 100 mL
5190-8275 1,000 µg/mL 5% HCl¬† 100 mL
5190-8345 1,000 µg/mL 5% HNO3 500 mL
5190-8276 1,000 µg/mL 5% HCl 500 mL

Single element lamps

Part No. Type Description
5610101200 Coded Chromium (Cr) coded single element hollow cathode lamp
5610123100 Uncoded Chromium (Cr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

25

Mn

25
54.94
Mn
7.43
15.64
1246
2061

Manganese

Atomic weight: 54.9380

Chemical form in solution: Mn(H2O)62+

Isotope abundance: 55 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-425 10 µg/mL Water with dilute nitric acid 125 mL
ICP-325 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-125 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-025 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-025-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-125-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-025 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-225 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8764 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8765 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8574 10 µg/mL 2% HNO3 100 mL
5190-8414 10,000 µg/mL 5% HNO3 100 mL
5190-8415 10,000 µg/mL 5% HNO3 500 mL
5190-8293 1,000 µg/mL 5% HNO3 100 mL
5190-8483 1,000 µg/mL 5% HNO3 100 mL
5190-8484 1,000 µg/mL 5% HNO3 500 mL
5190-8294 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103300 Coded Manganese (Mn) coded single element hollow cathode lamp
5610125200 Uncoded Manganese (Mn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133700 High intensity UltrAA Manganese (Mn) high intensity UltrAA coded single element hollow cathode lamp

26

Fe

26
55.85
Fe
7.90
16.19
1538
2861

Iron

Atomic weight: 55.847

Chemical form in solution: Fe(H2O)63+

Isotope abundance: 54 (5.85%); 56 (91.75%)*; 57 (2.12%); 58 (0.28%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-426 10 µg/mL Water with dilute nitric acid 125 mL
ICP-326 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-026 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-126 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-126-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-026 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-226 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8754 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8755 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8402 10,000 µg/mL 5% HNO3 100 mL
5190-8403 10,000 µg/mL 5% HNO3 500 mL
5190-8285 1,000 µg/mL 5% HNO3 100 mL
5190-8471 1,000 µg/mL 5% HNO3 100 mL
5190-8286 1,000 µg/mL 5% HNO3 500 mL
5190-8472 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610102700 Coded Iron (Fe) coded single element hollow cathode lamp
5610124600 Uncoded Iron (Fe) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108600 High intensity UltrAA Iron (Fe) high intensity UltrAA coded single element hollow cathode lamp

27

Co

27
58.93
Co
7.88
17.08
1495
2927

Cobalt

Atomic weight: 58.9332

Chemical form in solution: Co(H2O)62+

Isotope abundance: 59 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-327 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-427 10 µg/mL Water with dilute nitric acid 125 mL
ICP-127 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-027 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-127-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-027 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8750 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8751 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8376 10,000 µg/mL 5% HNO3 100 mL
5190-8377 10,000 µg/mL 5% HNO3 500 mL
5190-8346 1,000 µg/mL 5% HNO3 100 mL
5190-8277 1,000 µg/mL 5% HNO3 100 mL
5190-8347 1,000 µg/mL 5% HNO3 500 mL
5190-8278 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610101300 Coded Cobalt (Co) coded single element hollow cathode lamp
5610123200 Uncoded Cobalt (Co) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134100 High intensity UltrAA Cobalt (Co) high intensity UltrAA coded single element hollow cathode lamp

28

Ni

28
58.69
Ni
7.64
18.17
1455
2913

Nickel

Atomic weight: 58.6934

Chemical form in solution: Ni(H2O)62+

Isotope abundance: 58 (68.08%); 60 (26.22%)*; 61 (1.14%); 62 (3.63%); 64 (0.93%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-428 10 µg/mL Water with dilute nitric acid 125 mL
ICP-328 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-128 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-028 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-028-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-128-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-028 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-228 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8769 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8770 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8576 10 µg/mL 2% HNO3 100 mL
5190-8422 10,000 µg/mL 5% HNO3 100 mL
5190-8423 10,000 µg/mL 5% HNO3 500 mL
5190-8298 1,000 µg/mL 5% HNO3 100 mL
5190-8491 1,000 µg/mL 5% HNO3 100 mL
5190-8299 1,000 µg/mL 5% HNO3 500 mL
5190-8492 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103700 Coded Nickel (Ni) coded single element hollow cathode lamp
5610125600 Uncoded Nickel (Ni) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108500 High intensity UltrAA Nickel (Ni) high intensity UltrAA coded single element hollow cathode lamp

29

Cu

29
63.55
Cu
7.73
20.29
1085
2560

Copper

Atomic weight: 63.546

Chemical form in solution: Cu(H2O)62+

Isotope abundance: 63 (69.15%)*; 65 (30.85%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-429 10 µg/mL Water with dilute nitric acid 125 mL
ICP-329 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-129 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-029 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-029-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-129-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-029 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-229 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8752 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8753 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8569 10 µg/mL 2% HNO3 100 mL
5190-8378 10,000 µg/mL 5% HNO3 100 mL
5190-8379 10,000 µg/mL 5% HNO3 500 mL
5190-8348 1,000 µg/mL 5% HNO3 100 mL
5190-8279 1,000 µg/mL 5% HNO3 100 mL
5190-8349 1,000 µg/mL 5% HNO3 500 mL
5190-8280 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610101400 Coded Copper (Cu) coded single element hollow cathode lamp
5610123300 Uncoded Copper (Cu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

30

Zn

30
65.38
Zn
9.39
17.96
420
907

Zinc

Atomic weight: 65.38

Chemical form in solution: Zn(OH)(aq)+

Isotope abundance: 64 (49.17%); 66 (27.73%)*; 67 (4.04%); 68 (18.45%); 70 (0.61%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-430 10 µg/mL Water with dilute nitric acid 125 mL
ICP-130 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-030 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-030-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-130-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-230 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8797 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8798 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8587 10 µg/mL 2% HNO3 100 mL
5190-8234 10,000 µg/mL 5% HNO3 100 mL
5190-8235 10,000 µg/mL 5% HNO3 500 mL
5190-8325 1,000 µg/mL 5% HNO3 100 mL
5190-8557 1,000 µg/mL 5% HNO3 100 mL
5190-8326 1,000 µg/mL 5% HNO3 500 mL
5190-8558 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610106800 Coded Zinc (Zn) coded single element hollow cathode lamp
5610128800 Uncoded Zinc (Zn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

31

Ga

31
69.72
Ga
6.00
20.52
30
2229

Gallium

Atomic weight: 69.723

Chemical form in solution: Ga(H2O)6+3

Isotope abundance: 69 (60.11%); 71 (39.89%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-131 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-031 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-031-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-231 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8388 10,000 µg/mL 5% HNO3 with 0.5% HCl 100 mL
5190-8389 10,000 µg/mL 5% HNO3 with 0.5% HCl 500 mL
5190-8457 1,000 µg/mL 5% HNO3 with 0.5% HCl 100 mL
5190-8458 1,000 µg/mL 5% HNO3 with 0.5% HCl 500 mL

Single element lamps

Part No. Type Description
5610123800 Uncoded Gallium (Ga) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

32

Ge

32
72.63
Ge
7.90
15.93
938
2833

Germanium

Atomic weight: 72.59

Chemical form in solution: Ge(OH)x(F)y2-

Isotope abundance: 70 (20.57%); 72 (27.45%)*; 73 (7.75%); 74 (36.50%); 76 (7.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stability unknown alone or mixed with all other metals as the Ge(OH)x(F)y2-. 1-10,000 ppm single element solutions as the Ge(OH)x(F)y2- chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-132 10,000 µg/mL Water with dilute hydrofluoric acid 125 mL
ICP-032 1,000 µg/mL Water with trace hydrofluoric acid 125 mL
ICP-032-25 1,000 µg/mL Water with trace hydrofluoric acid 25 mL
ICP-132-25 10,000 µg/mL Water with trace hydrofluoric acid 25 mL
IAA-032 10,000 µg/mL Water with trace hydrofluoric acid 10 mL
5190-8592 10 µg/mL 2% HNO3 with trace HF 100 mL
5190-8390 10,000 µg/mL 5% HNO3 with trace HF 100 mL
5190-8391 10,000 µg/mL 5% HNO3 with trace HF 500 mL
5190-8459 1,000 µg/mL 5% HNO3 with trace HF 100 mL
5190-8460 1,000 µg/mL 5% HNO3 with trace HF 500 mL

Single element lamps

Part No. Type Description
5610123900 Uncoded Germanium (Ge) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134300 High intensity UltrAA Germanium (Ge) high intensity UltrAA coded single element hollow cathode lamp

33

As

33
74.92
As
9.79
18.59
616
616

Arsenic

Atomic weight: 74.9216

Chemical form in solution: H3AsO4 and HAsO2

Isotope abundance: 75 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5/+3mix, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stable for months alone or mixed with other elements at equivalent levels—in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-433 10 µg/mL Water with dilute nitric acid 125 mL
ICP-133 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-333 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-033 1,000 µg/mL Water with dilute nitric acid 125 mL
IAA-033 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-233 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8735 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8563 10 µg/mL 2% HNO3 100 mL
5190-8356 10,000 µg/mL 5% HNO3 100 mL
5190-8357 10,000 µg/mL 5% HNO3 500 mL
5190-8246 1,000 µg/mL 5% HNO3 100 mL
5190-8260 1,000 µg/mL 5% HNO3 100 mL
5190-8247 1,000 µg/mL 5% HNO3 500 mL
5190-8261 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610100300 Coded Arsenic (As) coded single element hollow cathode lamp
5610122200 Uncoded Arsenic (As) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108100 High intensity UltrAA Arsenic (As) high intensity UltrAA coded single element hollow cathode lamp

34

Se

34
78.97
Se
9.75
21.19
221
685

Selenium

Atomic weight: 78.96

Chemical form in solution: H2SeO3

Isotope abundance: 74 (0.89%); 76 (9.37%); 77 (7.63%); 78 (23.77%)*; 80 (49.61%); 82 (8.73%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +4, +1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months alone or mixed with other elements at equivalent levels in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-334 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-134 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-034 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-034-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-134-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-034 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-234 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8776 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8579 10 µg/mL 2% HNO3 100 mL
5190-8448 10,000 µg/mL 5% HNO3 100 mL
5190-8449 10,000 µg/mL 5% HNO3 500 mL
5190-8306 1,000 µg/mL 5% HNO3 100 mL
5190-8519 1,000 µg/mL 5% HNO3 100 mL
5190-8520 1,000 µg/mL 5% HNO3 500 mL
5190-8307 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610105000 Coded Selenium (Se) coded single element hollow cathode lamp
5610127000 Uncoded Selenium (Se) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108300 High intensity UltrAA Selenium (Se) high intensity UltrAA coded single element hollow cathode lamp

35

Br

35
79.90
Br
11.81
21.59
-7
59

Bromine

Atomic weight: 79.904

Isotope abundance: 79 (50.69%)*; 81 (49.31%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +4, +3, +1, -1

36

Kr

36
83.80
Kr
14.00
24.36
-157
-153

Krypton

Atomic weight: 83.8

Isotope abundance: 78 (0.35%); 80 (2.29%); 82 (11.59%); 83 (11.50%); 84 (56.99%); 86 (17.28%)

Oxidation states: +2

37

Rb

37
85.47
Rb
4.18
27.29
39.3
688

Rubidium

Atomic weight: 85.4678

Chemical form in solution: Rb+(aq)

Isotope abundance: 85 (72.17%)*; 87 (27.83%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1-1% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-037 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-037-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-237 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8440 10,000 µg/mL 5% HNO3 100 mL
5190-8441 10,000 µg/mL 5% HNO3 500 mL
5190-8511 1,000 µg/mL 5% HNO3 100 mL
5190-8512 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610126600 Uncoded Rubidium (Rb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

38

Sr

38
87.62
Sr
5.69
11.03
777
1377

Strontium

Atomic weight: 87.62

Chemical form in solution: Sr(H2O)6+2

Isotope abundance: 84 (0.56%); 86 (9.86%); 87 (7.00%); 88 (82.58%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-438 10 µg/mL Water with dilute nitric acid 125 mL
ICP-138 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-338 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-038 1,000 µg/mL Water with dilute nitric acid 125 mL
IAA-038 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-238 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8783 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8581 10 µg/mL 2% HNO3 100 mL
5190-8207 10,000 µg/mL 5% HNO3 100 mL
5190-8208 10,000 µg/mL 5% HNO3 500 mL
5190-8313 1,000 µg/mL 5% HNO3 100 mL
5190-8527 1,000 µg/mL 5% HNO3 100 mL
5190-8314 1,000 µg/mL 5% HNO3 500 mL
5190-8528 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610105400 Coded Strontium (Sr) coded single element hollow cathode lamp
5610127400 Uncoded Strontium (Sr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

39

Y

39
88.91
Y
6.22
12.22
1522
3345

Yttrium

Atomic weight: 88.9059

Chemical form in solution: Y(OH)(H2O)x+2

Isotope abundance: 89 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-139 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-039 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-039-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-139-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-039 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-239 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8795 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8796 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8586 10 µg/mL 2% HNO3 100 mL
5190-8232 10,000 µg/mL 5% HNO3 100 mL
5190-8233 10,000 µg/mL 5% HNO3 500 mL
5190-8555 1,000 µg/mL 5% HNO3 100 mL
5190-8556 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610128700 Uncoded Yttrium (Y) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

40

Zr

40
91.22
Zr
6.63
13.1
1854
4406

Zirconium

Atomic weight: 91.224

Chemical form in solution: Zr(F)6-2

Isotope abundance: 90 (51.45%)*; 91 (11.22%); 92 (17.15%); 94 (17.38%); 96 (2.80%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2, 0, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Zr(F)6-2 + Zr(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Zr(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-140 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-040 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-040-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-040 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8799 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8800 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8236 10,000 µg/mL 5% HNO3 100 mL
5190-8327 1,000 µg/mL 5% HNO3 100 mL
5190-8559 1,000 µg/mL 5% HNO3 100 mL
5190-8560 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610106900 Coded Zirconium (Zr) coded single element hollow cathode lamp
5610128900 Uncoded Zirconium (Zr) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

41

Nb

41
92.91
Nb
6.76
14.0
2477
4741

Niobium

Atomic weight: 92.9064

Chemical form in solution: NbOF5-2

Isotope abundance: 93 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +2, +1, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the NbOF5-2 for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the NbOF5-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-141 10,000 µg/mL Water with trace hydrofluoric acid 125 mL
ICP-041 1,000 µg/mL Water with trace hydrofluoric acid 125 mL
ICP-041-25 1,000 µg/mL Water with trace hydrofluoric acid 25 mL
5190-8424 10,000 µg/mL 2% HF 100 mL
5190-8425 10,000 µg/mL 2% HF 500 mL
5190-8493 1,000 µg/mL 2% HF 100 mL

Single element lamps

Part No. Type Description
5610103800 Coded Niobium (Nb) coded single element hollow cathode lamp
5610125700 Uncoded Niobium (Nb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

42

Mo

42
95.95
Mo
7.09
16.16
2622
4639

Molybdenum

Atomic weight: 95.96

Chemical form in solution: MoO4-2 (chem. form as received)

Isotope abundance: 92 (14.53%); 94 (9.15%); 95 (15.84%)*; 96 (16.67%); 97 (9.60%); 98 (24.39%); 100 (9.82%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the MoOF5-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the MoO4-2 chemically stable for years in 1% NH4OH in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl
  • HF
  • H2SO4 if complexed with F-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-442 10 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-342 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-142 10,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-042 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-042-25 1,000 µg/mL Water with dilute ammonium hydroxide 25 mL
ICP-142-25 10,000 µg/mL Water with dilute ammonium hydroxide 25 mL
IAA-042 10,000 µg/mL Water with dilute ammonium hydroxide 10 mL
5190-8767 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8768 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8418 10,000 µg/mL 1% NH4OH 100 mL
5190-8419 10,000 µg/mL 1% NH4OH 500 mL
5190-8297 1,000 µg/mL 1% NH4OH 100 mL
5190-8487 1,000 µg/mL 1% NH4OH 100 mL
5190-8488 1,000 µg/mL 1% NH4OH 500 mL

Single element lamps

Part No. Type Description
5610103500 Coded Molybdenum (Mo) coded single element hollow cathode lamp
5610125400 Uncoded Molybdenum (Mo) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

43

Tc

43
(98)
Tc
7.28
15.26
2157
4262

Technetium

Atomic weight: (98)

Oxidation states: +7, +6, +5, +4, 0, -1

44

Ru

44
101.1
Ru
7.36
16.76
2333
4147

Ruthenium

Atomic weight: 101.07

Chemical form in solution: RuCl6

Isotope abundance: 96 (5.54%); 98 (1.87%); 99 (12.76%); 100 (12.60%); 101 (17.06%)*; 102 (31.55%); 104 (18.62%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +8, +7, +6, +5, +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-044 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
5190-8442 10,000 µg/mL 20% HCl 100 mL
5190-8443 10,000 µg/mL 20% HCl 500 mL
5190-8513 1,000 µg/mL 20% HCl 100 mL
5190-8514 1,000 µg/mL 20% HCl 500 mL

Single element lamps

Part No. Type Description
5610126700 Uncoded Ruthenium (Ru) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

45

Rh

45
102.9
Rh
7.46
18.08
1963
3695

Rhodium

Atomic weight: 102.91

Chemical form in solution: RhCl6-3

Isotope abundance: 103 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1, 0, -1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-045 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-045-25 1,000 µg/mL Water with dilute hydrochloric acid 25 mL
5190-8439 10,000 µg/mL 20% HCl 500 mL
5190-8509 1,000 µg/mL 20% HCl 100 mL
5190-8510 1,000 µg/mL 20% HCl 500 mL

Single element lamps

Part No. Type Description
5610104500 Coded Rhodium (Rh) coded single element hollow cathode lamp
5610126500 Uncoded Rhodium (Rh) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

46

Pd

46
106.4
Pd
8.34
19.43
1555
2963

Palladium

Atomic weight: 106.42

Chemical form in solution: Pd(H2O)62+

Isotope abundance: 102 (1.02%); 104 (11.14%); 105 (22.33%)*; 106 (27.33%); 108 (26.46%); 110 (11.72%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2 ppb Pd is stable for 1 day in 1% HNO3/LDPE container. 10 ppb is stable for 3 days in 1% HNO3/LDPE container. 100 ppb is stable for ≥ 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-146 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-046 1,000 µg/mL Water with dilute nitric and hydrochloric acids 125 mL
ICP-146-25 10,000 µg/mL Water with dilute nitric and hydrochloric acids 25 mL
IAA-246 1,000 µg/mL Water with dilute nitric and hydrochloric acids 125 mL
5190-8426 10,000 µg/mL 10% HNO3 100 mL
5190-8427 10,000 µg/mL 10% HNO3 500 mL
5190-8300 1,000 µg/mL 20% HCl 100 mL
5190-8497 1,000 µg/mL 5% HNO3 100 mL
5190-8301 1,000 µg/mL 20% HCl 500 mL
5190-8498 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610104000 Coded Palladium (Pd) coded single element hollow cathode lamp
5610125900 Uncoded Palladium (Pd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135800 High intensity UltrAA Palladium (Pd) high intensity UltrAA coded single element hollow cathode lamp

47

Ag

47
107.9
Ag
7.58
21.48
962
2162

Silver

Atomic weight: 107.8682

Chemical form in solution: Ag(H2O)6+

Isotope abundance: 107 (51.84%)*; 109 (48.16%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for 75+ days when mixed with equivalent levels of all other elements including the precious metals (where chloride is present) when in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (trace levels of HCl or Cl- will form AgCl and will photoreduce to Ag0)
  • HCl (35%+ HCl will keep 100+ ug/mL of Ag+ in solution. HCl can be lowered to 10% to keep 10 ug/mL Ag in solution)
  • H2SO4 (trace levels of Cl- will photoreduce to Ag0, which is photosensitive)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-447 10 µg/mL Water with dilute nitric acid 125 mL
ICP-047 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-147 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-047-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-047 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-247 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8779 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8780 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8580 10 µg/mL 2% HNO3 100 mL
5190-8452 10,000 µg/mL 5% HNO3 100 mL
5190-8453 10,000 µg/mL 5% HNO3 500 mL
5190-8309 1,000 µg/mL 5% HNO3 100 mL
5190-8523 1,000 µg/mL 5% HNO3 100 mL
5190-8310 1,000 µg/mL 5% HNO3 500 mL
5190-8524 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610105200 Coded Silver (Ag) coded single element hollow cathode lamp
5610127200 Uncoded Silver (Ag) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

48

Cd

48
112.4
Cd
8.99
16.91
321
767

Cadmium

Atomic weight: 112.41

Chemical form in solution: Cd2(OH)(aq)3+ and Cd(OH)(aq)+

Isotope abundance: 106 (1.25%); 108 (0.89%); 110 (12.49%); 111 (12.80%)*; 112 (24.13%); 113 (12.22%); 114 (28.73%); 116 (7.49%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-448 10 µg/mL Water with dilute nitric acid 125 mL
ICP-348 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-148 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-048 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-048-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-048 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-248 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8742 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8743 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8567 10 µg/mL 2% HNO3 100 mL
5190-8366 10,000 µg/mL 5% HNO3 100 mL
5190-8367 10,000 µg/mL 5% HNO3 500 mL
5190-9414 1,000 µg/mL 5% HNO3 100 mL
5190-8270 1,000 µg/mL 5% HNO3 100 mL
5190-8328 1,000 µg/mL 5% HNO3 500 mL
5190-8271 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610100800 Coded Cadmium (Cd) coded single element hollow cathode lamp
5610122700 Uncoded Cadmium (Cd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

49

In

49
114.8
In
5.79
18.87
157
2027

Indium

Atomic weight: 114.82

Chemical form in solution: In(H2O)6+3

Isotope abundance: 113 (4.29%); 115 (95.71%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-149 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-049 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-049-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8398 10,000 µg/mL 5% HNO3 100 mL
5190-8399 10,000 µg/mL 5% HNO3 500 mL
5190-8467 1,000 µg/mL 5% HNO3 100 mL
5190-8284 1,000 µg/mL 5% HNO3 100 mL
5190-8468 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610124400 Uncoded Indium (In) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

50

Sn

50
118.7
Sn
7.34
14.63
232
2586

Tin

Atomic weight: 118.710

Chemical form in solution: Sn(OH)xFy2-

Isotope abundance: 112 (0.97%); 114 (0.66%); 115 (0.34%); 116 (14.54%); 117 (7.68%); 118 (24.22%)*; 119 (8.59%); 120 (32.58%); 122 (4.63%); 124 (5.79%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the Sn(OH)xFy2- for 1 year in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Sn(OH)xFy2- are chemically stable for years in 2-5% HNO3/trace HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (if complexed with F- / tartaric acid complex can be diluted in HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (if complexed with F- / tartaric acid complex can be diluted in HNO3)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-450 10 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-150 10,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-050 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
ICP-050-25 1,000 µg/mL Water with dilute nitric and trace HF acids 25 mL
IAA-050 10,000 µg/mL Water with dilute nitric and trace HF acids 10 mL
IAA-250 1,000 µg/mL Water with dilute nitric and trace HF acids 125 mL
5190-8787 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8788 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8583 10 µg/mL 5% HCl 100 mL
5190-8221 10,000 µg/mL 20% HCl 100 mL
5190-8222 10,000 µg/mL 20% HCl 500 mL
5190-8318 1,000 µg/mL 20% HCl 100 mL
5190-8543 1,000 µg/mL 20% HCl 100 mL
5190-8319 1,000 µg/mL 20% HCl 500 mL
5190-8544 1,000 µg/mL 20% HCl 500 mL

Single element lamps

Part No. Type Description
5610106100 Coded Tin (Sn) coded single element hollow cathode lamp
5610128100 Uncoded Tin (Sn) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610133900 High intensity UltrAA Tin (Sn) high intensity UltrAA coded single element hollow cathode lamp

51

Sb

51
121.8
Sb
8.61
16.63
631
1587

Antimony

Atomic weight: 121.75

Chemical form in solution: Sb(O)C4H4O6-

Isotope abundance: 121 (57.21%)*; 123 (42.79%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-2% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • Tartaric acid complex can be diluted HNO3
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-
  • Tartaric acid complex can be compatible with H2SO4

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-451 10 µg/mL Water with dilute nitric acid 125 mL
ICP-351 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-051-25 1,000 µg/mL Water with dilute nitric and trace tartaric acids 25 mL
IAA-051 10,000 µg/mL Water with trace nitric and tartaric acids 10 mL
5190-8354 10,000 µg/mL 1% HNO3 and trace tartaric acid 100 mL
5190-8355 10,000 µg/mL 1% HNO3 and trace tartaric acid 500 mL
5190-8733 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8734 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8562 10 µg/mL 1% HNO3 and trace tartaric acid 100 mL
5190-8244 1,000 µg/mL 1% HNO3 and trace tartaric acid 100 mL
5190-8258 1,000 µg/mL 30% HCl 100 mL
5190-8245 1,000 µg/mL 1% HNO3 and trace tartaric acid 500 mL
5190-8259 1,000 µg/mL 30% HCl 500 mL

Single element lamps

Part No. Type Description
5610100200 Coded Antimony (Sb) coded single element hollow cathode lamp
5610122100 Uncoded Antimony (Sb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108000 High intensity UltrAA Antimony (Sb) high intensity UltrAA coded single element hollow cathode lamp

52

Te

52
127.6
Te
9.01
18.60
450
988

Tellurium

Atomic weight: 127.60

Chemical form in solution: H2TeO3 (HNO3 matrix), TeCl62- (HCl matrix)

Isotope abundance: 120 (0.09%); 122 (2.55%); 123 (0.89%); 124 (4.74%); 125 (7.07%)*; 126 (18.84%); 128 (31.74%); 130 (34.08%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +2, -1, -2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months alone or mixed with other elements at equivalent levels in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (not soluable above 1000 ug/mL)
  • HCl
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-152 10,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-052 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-052-25 1,000 µg/mL Water with dilute hydrochloric acid 25 mL
ICP-152-25 10,000 µg/mL Water with dilute hydrochloric acid 25 mL
5190-8213 10,000 µg/mL 30% HCl 100 mL
5190-8214 10,000 µg/mL 30% HCl 500 mL
5190-8315 1,000 µg/mL 5% HNO3 100 mL
5190-8533 1,000 µg/mL 30% HCl 100 mL
5190-8534 1,000 µg/mL 30% HCl 500 mL

Single element lamps

Part No. Type Description
5610105600 Coded Tellurium (Te) coded single element hollow cathode lamp
5610127600 Uncoded Tellurium (Te) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134000 High intensity UltrAA Tellurium (Te) high intensity UltrAA coded single element hollow cathode lamp

53

I

53
126.9
I
10.45
19.13
114
184

Iodine

Atomic weight: 126.905

Isotope abundance: 127 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +3, +1, 0, -1

54

Xe

54
131.3
Xe
12.13
20.97
-112
-108

Xenon

Atomic weight: 131.29

Isotope abundance: 124 (0.09%); 126 (0.09%); 128 (1.92%); 129 (26.40%); 130 (4.07%); 131 (21.23%); 132 (26.91%); 134 (10.44%); 136 (8.86%)

Oxidation states: +8, +6, +4, +2

55

Cs

55
132.9
Cs
3.89
23.16
28.5
671

Cesium

Atomic weight: 132.9054

Chemical form in solution: Cs+(aq)

Isotope abundance: 133 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 0.1% HNO3/LDPE container. Will crystallize out of higher (~ 5%) levels of HNO3 at > 1000 µg/mL.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2O at pH 7
  • HF
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-055 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-155 10,000 µg/mL Water with dilute nitric acid 125 mL
IAA-255 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8372 10,000 µg/mL 5% HNO3 100 mL
5190-8373 10,000 µg/mL 5% HNO3 500 mL
5190-8333 1,000 µg/mL 5% HNO3 100 mL
5190-8274 1,000 µg/mL 5% HNO3 100 mL
5190-8334 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610122800 Uncoded Cesium (Cs) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

56

Ba

56
137.3
Ba
5.21
10.00
727
1845

Barium

Atomic weight: 137.33

Chemical form in solution: Ba(H2O)6+2

Isotope abundance: 130 (0.11%); 132 (0.10%); 134 (2.42%); 135 (6.59%); 136 (7.85%); 137 (11.23%)*; 138 (71.70%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-3.5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-356 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-156 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-056-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-056 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-256 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8736 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8737 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8564 10 µg/mL 2% HNO3 100 mL
5190-8358 10,000 µg/mL 5% HNO3 100 mL
5190-8359 10,000 µg/mL 5% HNO3 500 mL
5190-8248 1,000 µg/mL 5% HNO3 100 mL
5190-8262 1,000 µg/mL 5% HNO3 100 mL
5190-8249 1,000 µg/mL 5% HNO3 500 mL
5190-8263 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610100400 Coded Barium (Ba) coded single element hollow cathode lamp
5610122300 Uncoded Barium (Ba) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

72

Hf

72
178.5
Hf
6.83
15.0
2233
4600

Hafnium

Atomic weight: 178.49

Chemical form in solution: Hf(F)6-2

Isotope abundance: 174 (0.16%); 176 (5.26%); 177 (18.60%); 178 (27.28%)*; 179 (13.62%); 180 (35.08%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable alone or mixed with all other metals that are at comparable levels as the Hf(F)6-2 + Hf(OH)4F2-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the Hf(F)6-2 chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with F-
  • HCl if complexed with F-
  • HF
  • H2SO4 if complexed with F-

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-072 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-172 10,000 µg/mL Water with trace hydrofluoric acid 125 mL
ICP-072-25 1,000 µg/mL Water with dilute hydrochloric acid 25 mL
5190-8394 10,000 µg/mL 5% HCl 100 mL
5190-8395 10,000 µg/mL 5% HCl 500 mL
5190-8463 1,000 µg/mL 5% HCl 100 mL
5190-8464 1,000 µg/mL 5% HCl 500 mL

Single element lamps

Part No. Type Description
5610102200 Coded Hafnium (Hf) coded single element hollow cathode lamp
5610124100 Uncoded Hafnium (Hf) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

73

Ta

73
180.9
Ta
7.55
3017
5455

Tantalum

Atomic weight: 180.9479

Chemical form in solution: TaOF6-3

Isotope abundance: 180 (0.01%); 181 (99.99%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +4, +3, +1, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the TaOF6-3, for 2 months at the 2-10 ppb level in 1% HNO3/LDPE container and for 5 months at the 100 ppb level under same conditions. 1-10,000 ppm single element solutions as the TaOF6-3 are chemically stable for years in 2-5% HNO3/trace HF in an LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should have excess HF present when diluted with HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (should have excess HF present when diluted with H2SO4)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-173 10,000 µg/mL Water with trace nitric and hydrofluoric acid 125 mL
ICP-073 1,000 µg/mL Water with trace hydrofluoric acid 125 mL
ICP-073-25 1,000 µg/mL Water with trace hydrofluoric acid 25 mL
5190-8212 10,000 µg/mL 2% HF 500 mL
5190-8531 1,000 µg/mL 2% HF 100 mL
5190-8532 1,000 µg/mL 2% HF 500 mL

Single element lamps

Part No. Type Description
5610105500 Coded Tantalum (Ta) coded single element hollow cathode lamp
5610127500 Uncoded Tantalum (Ta) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

74

W

74
183.8
W
7.86
16.10
3414
5555

Tungsten

Atomic weight: 183.85

Chemical form in solution: WOF5-2 (chem. form as received)

Isotope abundance: 180 (0.12%); 182 (26.50%)*; 183 (14.31%); 184 (30.64%); 186 (28.43%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, 0, -1, -2, -4

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable (alone or mixed with all other metals that are at comparable levels) as the [WOF5]-2 for months in 1% HNO3/LDPE container. 1-10,000 ppm single element solutions as the [WOF5]-2 chemically stable for years in 1% HF in a LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should have excess HF present when diluted with HNO3)
  • HCl if complexed with F-
  • HF
  • H2SO4 (should have excess HF present when diluted with H2SO4)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-174 10,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-074 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
ICP-074-25 1,000 µg/mL Water with dilute ammonium hydroxide 25 mL
IAA-274 1,000 µg/mL Water with dilute ammonium hydroxide 125 mL
5190-8791 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8792 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8226 10,000 µg/mL 5% HNO3 with trace HF 100 mL
5190-8227 10,000 µg/mL 5% HNO3 with trace HF 500 mL
5190-8547 1,000 µg/mL 5% HNO3 with trace HF 100 mL
5190-8548 1,000 µg/mL 5% HNO3 with trace HF 500 mL

Single element lamps

Part No. Type Description
5610128300 Uncoded Tungsten (W) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

75

Re

75
186.2
Re
7.83
3185
5590

Rhenium

Atomic weight: 186.207

Chemical form in solution: ReO4-

Isotope abundance: 185 (37.40%)*; 187 (62.60%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +6, +5, +4, +3, +2, +1, 0, -1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-175 10,000 µg/mL Water with trace nitric acid 125 mL
ICP-075 1,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
IAA-275 1,000 µg/mL Water (low TOC, < 50 ppb) 125 mL
5190-8437 10,000 µg/mL 5% HNO3 500 mL
5190-8507 1,000 µg/mL 5% HNO3 100 mL
5190-8508 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610104400 Coded Rhenium (Re) coded single element hollow cathode lamp
5610126400 Uncoded Rhenium (Re) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

76

Os

76
190.2
Os
8.44
3033
5008

Osmium

Atomic weight: 190.2

Chemical form in solution: OsCl62-

Isotope abundance: 184 (0.02%); 186 (1.59%); 187 (1.96%); 188 (13.24%); 189 (16.15%)*; 190 (26.26%); 192 (40.78%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +8, +7, +6, +5, +4, +3, +2, +1, 0, -2

77

Ir

77
192.2
Ir
8.97
2446
4428

Iridium

Atomic weight: 192.22

Chemical form in solution: IrCl6-2

Isotope abundance: 191 (37.3%); 193 (62.7%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3, +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if completed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-177 10,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-077 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-077-25 1,000 µg/mL Water with dilute hydrochloric acid 25 mL
ICP-177-25 10,000 µg/mL Water with dilute hydrochloric acid 25 mL
5190-8588 10 µg/mL 2% HCl 100 mL
5190-8570 10 µg/mL 2% HCl 100 mL
5190-8400 10,000 µg/mL 20% HCl 100 mL
5190-9415 10,000 µg/mL 20% HCl 500 mL
5190-8469 1,000 µg/mL 20% HCl 100 mL
5190-8470 1,000 µg/mL 20% HCl 500 mL
5190-8495 1,000 µg/mL 20% HCl 100 mL

Single element lamps

Part No. Type Description
5610102600 Coded Iridium (Ir) coded single element hollow cathode lamp
5610124500 Uncoded Iridium (Ir) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

78

Pt

78
195.1
Pt
8.96
18.56
1768
3825

Platinum

Atomic weight: 195.08

Chemical form in solution: Pt(Cl)62-

Isotope abundance: 190 (0.012%); 192 (0.782%); 194 (32.86%); 195 (33.78%)*; 196 (25.21%); 198 (7.356%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +2, 0

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-10 ppb Pt is stable for 2 months in 1% HNO3/LDPE container. 100 ppb is stable for 5 months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if complexed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-178 10,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-078 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
5190-8577 10 µg/mL 5% HCl 100 mL
5190-8430 10,000 µg/mL 20% HCl 100 mL
5190-8431 10,000 µg/mL 20% HCl 500 mL
5190-8302 1,000 µg/mL 20% HCl 100 mL
5190-8501 1,000 µg/mL 20% HCl 100 mL
5190-8303 1,000 µg/mL 20% HCl 500 mL
5190-8502 1,000 µg/mL 20% HCl 500 mL

Single element lamps

Part No. Type Description
5610104100 Coded Platinum (Pt) coded single element hollow cathode lamp
5610126100 Uncoded Platinum (Pt) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610135900 High intensity UltrAA Platinum (Pt) high intensity UltrAA coded single element hollow cathode lamp

79

Au

79
197.0
Au
9.23
20.2
1064
2836

Gold

Atomic weight: 196.9665

Chemical form in solution: Au(Cl)63-

Isotope abundance: 197 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +7, +5, +3, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels. 2-10 ppb Au is stable for ≤ 1 day maximum in 1% HNO3/LDPE container. 100 ppb is stable for ≤ 2 days maximum in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 10% HCl/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 if complexed with Cl-
  • HCl
  • H2SO4 if completed with Cl-
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-179 10,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-379 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-079 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
ICP-079-25 1,000 µg/mL Water with dilute hydrochloric acid 25 mL
IAA-279 1,000 µg/mL Water with dilute hydrochloric acid 125 mL
5190-8392 10,000 µg/mL 20% HCl 100 mL
5190-8393 10,000 µg/mL 20% HCl 500 mL
5190-8461 1,000 µg/mL 20% HCl 100 mL
5190-8282 1,000 µg/mL 20% HCl 100 mL
5190-8462 1,000 µg/mL 20% HCl 500 mL
5190-8283 1,000 µg/mL 20% HCl 500 mL

Single element lamps

Part No. Type Description
5610102100 Coded Gold (Au) coded single element hollow cathode lamp
5610124000 Uncoded Gold (Au) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610109000 High intensity UltrAA Gold (Au) high intensity UltrAA coded single element hollow cathode lamp

80

Hg

80
200.6
Hg
10.44
18.76
-39
357

Mercury

Atomic weight: 200.59

Chemical form in solution: Hg(OH)(aq)+

Isotope abundance: 196 (0.15%); 198 (9.97%); 199 (16.87%); 200 (23.10%); 201 (13.18%)*; 202 (29.86%)*; 204 (6.87%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +2, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels—stable in 10% HNO3 packaged in borosilicate glass; NOT stable in 1% HNO3/ LDPE container. 1-100 ppm levels stable in 7% HNO3 packaged in borosilicate glass. 1000-10,000 ppm solutions are chemically stable for years in 5-10% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3 (should be stored in borosilicate glass)
  • HCl (preferred matrix due to less adsorption)
  • H2SO4 (should be stored in borosilicate glass)
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-180 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-480 10 µg/mL Water with dilute nitric acid 125 mL
ICP-380 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-080 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-080-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-180-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-080 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-280 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8766 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8575 10 µg/mL 5% HNO3 100 mL
5190-8416 10,000 µg/mL 5% HNO3 100 mL
5190-8417 10,000 µg/mL 5% HNO3 500 mL
5190-8295 1,000 µg/mL 5% HNO3 100 mL
5190-8485 1,000 µg/mL 5% HNO3 100 mL
5190-8486 1,000 µg/mL 5% HNO3 500 mL
5190-8296 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103400 Coded Mercury (Hg) coded single element hollow cathode lamp
5610125300 Uncoded Mercury (Hg) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

81

Tl

81
204.4
Tl
6.11
20.43
304
1473

Thallium

Atomic weight: 204.383

Chemical form in solution: Tl(H2O)6+

Isotope abundance: 203 (29.52%); 205 (70.48%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +1

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-381 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-181 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-081 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-081-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-081 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-281 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8786 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8217 10,000 µg/mL 5% HNO3 100 mL
5190-8316 1,000 µg/mL 5% HNO3 100 mL
5190-8537 1,000 µg/mL 5% HNO3 100 mL
5190-8317 1,000 µg/mL 5% HNO3 500 mL
5190-8538 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610105800 Coded Thallium (Tl) coded single element hollow cathode lamp
5610127800 Uncoded Thallium (Tl) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108400 High intensity UltrAA Thallium (Tl) high intensity UltrAA coded single element hollow cathode lamp

82

Pb

82
207.2
Pb
7.42
15.03
327
1749

Lead

Atomic weight: 207.2

Chemical form in solution: Pb(H2O)6+2

Isotope abundance: 204 (1.4%); 206 (24.1%); 207 (22.1%); 208 (52.4%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-482 10 µg/mL Water with dilute nitric acid 125 mL
ICP-382 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-182 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-082 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-082-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-182-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-082 10,000 µg/mL Water with dilute nitric acid 10 mL
IAA-282 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8758 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8759 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8571 10 µg/mL 2% HNO3 100 mL
5190-8406 10,000 µg/mL 5% HNO3 100 mL
5190-8407 10,000 µg/mL 5% HNO3 500 mL
5190-8287 1,000 µg/mL 5% HNO3 100 mL
5190-8475 1,000 µg/mL 5% HNO3 100 mL
5190-8288 1,000 µg/mL 5% HNO3 500 mL
5190-8476 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610102900 Coded Lead (Pb) coded single element hollow cathode lamp
5610124800 Uncoded Lead (Pb) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610108200 High intensity UltrAA Lead (Pb) high intensity UltrAA coded single element hollow cathode lamp

83

Bi

83
209.0
Bi
7.29
16.70
271
1564

Bismuth

Atomic weight: 208.9804

Chemical form in solution: Bi(O)(H2O)x+

Isotope abundance: 209 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +5, +3, +1, -3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 5-7% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-183 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-083 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-183-25 10,000 µg/mL Water with dilute nitric acid 25 mL
IAA-083 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8739 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8362 10,000 µg/mL 5% HNO3 100 mL
5190-8363 10,000 µg/mL 5% HNO3 500 mL
5190-8252 1,000 µg/mL 5% HNO3 100 mL
5190-8266 1,000 µg/mL 5% HNO3 100 mL
5190-8253 1,000 µg/mL 5% HNO3 500 mL
5190-8267 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610100600 Coded Bismuth (Bi) coded single element hollow cathode lamp
5610122500 Uncoded Bismuth (Bi) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector
5610134200 High intensity UltrAA Bismuth (Bi) high intensity UltrAA coded single element hollow cathode lamp

84

Po

84
(209)
Po
8.41
254
962

Polonium

Atomic weight: (209)

Oxidation states: +6, +4, +2, -2

85

At

85
(210)
At
 
300
350

Astatine

Atomic weight: (210)

Oxidation states: +3, +1, -1

86

Rn

86
(222)
Rn
10.75
-71
-62

Radon

Atomic weight: (222)

Oxidation states: +2

87

Fr

87
(223)
Fr
4.07
21
650

Francium

Atomic weight: (223)

Oxidation states: +1

88

Ra

88
(226)
Ra
5.28
10.15
696
1500

Radium

Atomic weight: 226.025

Oxidation states: +2

104

Rf

104
(267)
Rf
6.0

Rutherfordium

Atomic weight: (267)

105

Db

105
(268)
Db

Dubnium

Atomic weight: (268)

106

Sg

106
(271)
Sg

Seaborgium

Atomic weight: (269)

107

Bh

107
(272)
Bh

Bohrium

Atomic weight: (270)

108

Hs

108
(270)
Hs

Hassium

Atomic weight: (277)

109

Mt

109
(276)
Mt

Meitnerium

Atomic weight: (278)

110

Ds

110
(281)
Ds

Darmstadtium

Atomic weight: (281)

111

Rg

111
(280)
Rg

Roentgenium

Atomic weight: (282)

112

Cn

112
(285)
Cn

Copernicium

Atomic weight: (285)

113

Uut

113
(284)
Uut

Ununtrium

Atomic weight: (284)

114

Fl

114
(289)
Fl

Flerovium

Atomic weight: (289)

115

Uup

115
(288)
Uup

Ununpentium

Atomic weight: (288)

116

Lv

116
(293)
Lv

Livermorium

Atomic weight: (293)

117

Uus

117
(294)
Uus

Ununseptium

Atomic weight: (294)

118

Uuo

118
(294)
Uuo

Ununoctium

Atomic weight: (294)

57

La

57
138.9
La
5.58
11.06
920
3464

Lanthanum

Atomic weight: 138.9055

Chemical form in solution: La(OH)y(H2O)x+3-y

Isotope abundance: 138 (0.09%); 139 (99.91%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-157 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-057 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-057-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-257 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8756 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8757 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8404 10,000 µg/mL 5% HNO3 100 mL
5190-8405 10,000 µg/mL 5% HNO3 500 mL
5190-8473 1,000 µg/mL 5% HNO3 100 mL
5190-8474 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610124700 Uncoded Lanthanum (La) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

58

Ce

58
140.1
Ce
5.54
10.85
799
3443

Cerium

Atomic weight: 140.12

Chemical form in solution: Ce(OH)y(H2O)x+4-y

Isotope abundance: 136 (0.19%); 138 (0.25%); 140 (88.45%)*; 142 (11.11%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-058 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-058-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8746 1,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8747 5,000 µg/g 75 cSt hydrocarbon oil 50 g
5190-8370 10,000 µg/mL 5% HNO3 100 mL
5190-8371 10,000 µg/mL 5% HNO3 500 mL
5190-8331 1,000 µg/mL 5% HNO3 100 mL
5190-8332 1,000 µg/mL 5% HNO3 500 mL

59

Pr

59
140.9
Pr
5.47
10.55
931
3520

Praseodymium

Atomic weight: 140.9077

Chemical form in solution: Pr(OH)y(H2O)x+3-y

Isotope abundance: 141 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-159 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-059 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-059-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8505 1,000 µg/mL 5% HNO3 100 mL

60

Nd

60
144.2
Nd
5.53
10.72
1016
3074

Neodymium

Atomic weight: 144.24

Chemical form in solution: Nd(OH)y(H2O)x+3-y

Isotope abundance: 142 (27.2%); 143 (12.2%); 144 (23.8%); 145 (8.3%); 146 (17.2%)*; 148 (5.7%); 150 (5.6%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-160 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-060 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-060-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8421 10,000 µg/mL 5% HNO3 500 mL
5190-8489 1,000 µg/mL 5% HNO3 100 mL
5190-8490 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610103600 Coded Neodymium (Nd) coded single element hollow cathode lamp
5610125500 Uncoded Neodymium (Nd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

61

Pm

61
(145)
Pm
5.58
10.90
1042
3000

Promethium

Atomic weight: (145)

Oxidation states: +3

62

Sm

62
150.4
Sm
5.64
11.07
1072
1794

Samarium

Atomic weight: 150.36

Chemical form in solution: Sm(OH)y(H2O)x+3-y

Isotope abundance: 144 (3.07%); 147 (14.99%)*; 148 (11.24%); 149 (13.82%); 150 (7.38%); 152 (26.75%); 154 (22.75%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-062 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-062-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8445 10,000 µg/mL 5% HNO3 500 mL
5190-8515 1,000 µg/mL 5% HNO3 100 mL

Single element lamps

Part No. Type Description
5610126800 Uncoded Samarium (Sa) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

63

Eu

63
152.0
Eu
5.67
11.25
822
1529

Europium

Atomic weight: 151.96

Chemical form in solution: Eu(OH)y(H2O)x+3-y

Isotope abundance: 151 (47.81%); 153 (52.19%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-063 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-163 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-063-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8385 10,000 µg/mL 5% HNO3 500 mL
5190-8239 1,000 µg/mL 5% HNO3 100 mL

Single element lamps

Part No. Type Description
5610123600 Uncoded Europium (Eu) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

64

Gd

64
157.3
Gd
6.15
12.09
1313
3273

Gadolinium

Atomic weight: 157.25

Chemical form in solution: Gd(OH)x(H2O)y+3-x

Isotope abundance: 152 (0.2%); 154 (2.18%); 155 (14.80%); 156 (20.47%); 157 (15.65%)*; 158 (24.84%); 160 (21.86%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-064 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-064-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-064 10,000 µg/mL Water with dilute nitric acid 10 mL
5190-8386 10,000 µg/mL 5% HNO3 100 mL
5190-8387 10,000 µg/mL 5% HNO3 500 mL
5190-8241 1,000 µg/mL 5% HNO3 100 mL
5190-8456 1,000 µg/mL 5% HNO3 500 mL

Single element lamps

Part No. Type Description
5610123700 Uncoded Gadolinium (Gd) uncoded single element hollow cathode lamp, for all AAS instruments with octal base connector

65

Tb

65
158.9
Tb
5.86
11.52
1359
3230

Terbium

Atomic weight: 158.9254

Chemical form in solution: Tb(OH)x(H2O)y+3-x

Isotope abundance: 159 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-165 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-065 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-065-25 1,000 µg/mL Water with dilute nitric acid 25 mL
ICP-165-25 10,000 µg/mL Water with dilute nitric acid 25 mL
5190-8590 10 µg/mL 2% HNO3 100 mL
5190-8582 10 µg/mL 2% HNO3 100 mL
5190-8216 10,000 µg/mL 5% HNO3 500 mL
5190-8535 1,000 µg/mL 5% HNO3 100 mL

66

Dy

66
162.5
Dy
5.94
11.67
1412
2567

Dysprosium

Atomic weight: 162.50

Chemical form in solution: Dy(OH)x(H2O)y+3-x

Isotope abundance: 156 (0.06%); 158 (0.09%); 160 (2.33%); 161 (18.89%); 162 (25.47%); 163 (24.90%)*; 164 (28.26%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-166 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-066 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-066-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8381 10,000 µg/mL 5% HNO3 500 mL
5190-8350 1,000 µg/mL 5% HNO3 100 mL

67

Ho

67
164.9
Ho
6.02
11.80
1472
2700

Holmium

Atomic weight: 164.9304

Chemical form in solution: Ho(OH)x(H2O)y+3-x

Isotope abundance: 165 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-067 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-067-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8397 10,000 µg/mL 5% HNO3 500 mL
5190-8465 1,000 µg/mL 5% HNO3 100 mL

68

Er

68
167.3
Er
6.11
11.93
1529
2868

Erbium

Atomic weight: 167.26

Chemical form in solution: Er(OH)x(H2O)y+3-x

Isotope abundance: 162 (0.14%); 164 (1.60%); 166 (33.50%)*; 167 (22.87%); 168 (26.98%); 170 (14.91%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-068 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-068-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8383 10,000 µg/mL 5% HNO3 500 mL
5190-8237 1,000 µg/mL 5% HNO3 100 mL

69

Tm

69
168.9
Tm
6.18
12.05
1545
1950

Thulium

Atomic weight: 168.9342

Chemical form in solution: Tm(OH)x(H2O)y+3-x

Isotope abundance: 169 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-069 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-069-25 1,000 µg/mL Water with dilute nitric acid 25 mL
5190-8220 10,000 µg/mL 5% HNO3 500 mL
5190-8541 1,000 µg/mL 5% HNO3 100 mL

70

Yb

70
173.1
Yb
6.25
12.18
824
1196

Ytterbium

Atomic weight: 173.054

Chemical form in solution: Yb(OH)x(H2O)y+3-x

Isotope abundance: 168 (0.12%); 170 (2.98%); 171 (14.09%); 172 (21.68%)*; 173 (16.10%); 174 (32.03%); 176 (13.00%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-070 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-170 10,000 µg/mL Water with dilute nitric acid 125 mL
IAA-270 1,000 µg/mL Water with dilute nitric acid 125 mL
5190-8231 10,000 µg/mL 5% HNO3 500 mL
5190-8553 1,000 µg/mL 5% HNO3 100 mL

71

Lu

71
175.0
Lu
5.43
13.90
1663
3402

Lutetium

Atomic weight: 174.9668

Chemical form in solution: Lu(OH)x(H2O)y+3-x

Isotope abundance: 175 (97.40%)*; 176 (2.60%)

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-171 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-071 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-171-25 10,000 µg/mL Water with dilute nitric acid 25 mL
5190-8591 10 µg/mL 2% HNO3 100 mL
5190-8573 10 µg/mL 2% HNO3 100 mL
5190-8410 10,000 µg/mL 5% HNO3 100 mL
5190-8411 10,000 µg/mL 5% HNO3 500 mL
5190-8479 1,000 µg/mL 5% HNO3 100 mL
5190-8480 1,000 µg/mL 5% HNO3 500 mL

89

Ac

89
(227)
Ac
5.17
11.75
1050
3200

Actinium

Atomic weight: 227.028

Oxidation states: +3

90

Th

90
232.0
Th
6.31
11.90
1750
4785

Thorium

Atomic weight: 232.0381

Chemical form in solution: Th(OH)3+ and Th(OH)22+

Isotope abundance: 232 (100%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +4, +3, +2

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-190 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-090 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-090-25 1,000 µg/mL Water with dilute nitric acid 25 mL
IAA-090 10,000 µg/mL Water with dilute nitric acid 10 mL

91

Pa

91
231.0
Pa
5.89
1572
4000

Protactinium

Atomic weight: 231.036

Oxidation states: +5, +4, +3

92

U

92
238.0
U
6.19
10.60
1135
4131

Uranium

Atomic weight: 238.0289

Chemical form in solution: UO22+ (uranyl)

Isotope abundance: 234 (0.005%); 235 (0.720%); 238 (99.274%)*

Highlighted isotope is the recommended mass number for ICP-MS analysis

Oxidation states: +6, +5, +4, +3

Storage conditions

Store at room temperature (15° to 30°C)

Stability

2-100 ppb levels stable for months in 1% HNO3/LDPE container. 1-10,000 ppm solutions chemically stable for years in 2-5% HNO3/LDPE container.

Matrix compatibility

  • Aqueous/HNO3
  • HCl
  • H2SO4
  • H3PO4 (not commonly used due to attacking containers)

Single element inorganic standards

Part No. Concentration Matrix Volume
ICP-192 10,000 µg/mL Water with dilute nitric acid 125 mL
ICP-092 1,000 µg/mL Water with dilute nitric acid 125 mL
ICP-092-25 1,000 µg/mL Water with dilute nitric acid 25 mL

93

Np

93
(237)
Np
6.27
644
3902

Neptunium

Atomic weight: 237.048

Oxidation states: +7, +6, +5, +4, +3, +2

94

Pu

94
(244)
Pu
6.03
11.20
640
3228

Plutonium

Atomic weight: (244)

Oxidation states: (+7), +6, +5, +4, +3, +2

95

Am

95
(243)
Am
5.97
1176
2011

Americium

Atomic weight: (243)

Oxidation states: +6, +5, +4, +3, +2

96

Cm

96
(247)
Cm
5.99
1345

Curium

Atomic weight: (247)

Oxidation states: +4, +3, +2

97

Bk

97
(247)
Bk
6.20
986

Berkelium

Atomic weight: (247)

Oxidation states: +4, +3, +2

98

Cf

98
(251)
Cf
6.28
11.80
900

Californium

Atomic weight: (251)

Oxidation states: +4, +3, +2

99

Es

99
(252)
Es
6.42
12.0
860

Einsteinium

Atomic weight: (254)

Oxidation states: (+4), +3, (+2)

100

Fm

100
(257)
Fm
6.50
1527

Fermium

Atomic weight: (257)

Oxidation states: +3, (+2)

101

Md

101
(258)
Md
6.58
827

Mendelevium

Atomic weight: (258)

Oxidation states: +3, +2

102

No

102
(259)
No
6.65
827

Nobelium

Atomic weight: (259)

Oxidation states: +3, +2

103

Lr

103
(262)
Lr
4.90
1627

Lawrencium

Atomic weight: (262)

Oxidation states: +3

Download a printable copy with a full relative isotopic abundance table.

Inorganic Standards

Your essential resource for Agilent ULTRA chemical standards

Download catalog

Custom standards

See how easy it is to narrow your search results, compare formulas, review pricing options, and request your custom standards

Watch video

Complete your inorganics workflow and gain the insights you need to achieve optimal results

Bond Elut box

Accurate, productive elemental analysis demands sample preparation that is straightforward, cost effective, and compatible with your analytical goals and methods. From filtration and purification to solid phase extraction, Agilent makes delivering accurate results easier. Learn more

vials

Vials are a critical part of your analytical workflow. Choose Agilent vials and closures and gain complete confidence in your sample containment—and your results. Learn more

chemical standards

ULTRA Scientific has been acquired by Agilent. That means we can now offer you a full portfolio of reliable and effective reference materials, along with easy online ordering, rapid shipping, and custom solutions. Learn more

torches

Agilent ICP-OES torches give you superior long-term stability—and are less susceptible to blockages—so, you can reduce your risk of unplanned downtime. Learn more

Never compromise on AA performance. Agilent hollow cathode lamps deliver excellent stability and sensitivity, improved detection limit performance, and a longer service life. Learn more

OneNeb Nebulizer

Agilent provides a range of high-quality ICP-OES supplies, including ICP-OES nebulizers and application kits, to support a range of atomic spectroscopy applications. Learn more

Agilent 240 AA

Productive, precise, and reliable. Agilent leads the industry with innovative AA instruments to match every need and budget—including the world’s fastest flame AA system. Learn more

Agilent 7800 ICP-MS

Perform fast, sensitive elemental analysis. Agilent ICP-MS systems give you excellent accuracy, ease of use, and productivity. Learn more

5110 ICP-OES

Whether for metals analysis, elemental analysis or investigation of organic solvents, our high-quality ICP-OES systems, accessories, supplies, and ICP Expert software can help you reach your analytical goals. Learn more

See our entire portfolio of instruments. Learn more

analysis

Our lab software portfolio features a range of high-quality solutions to ensure your laboratory can make the most of every analytical system. Learn more

method and application consulting

Avoid the time and costs of developing new methods from scratch, restoring methods after a repair, and transitioning methods to new instruments. Agilent CrossLab application support can help you confidently deploy the latest productivity and usability enhancements and ensure the best outcomes—from sample preparation to final report. Learn more

CrossLab

Agilent CrossLab service engineers have the skills, qualifications, and experience to manage all your instrument servicing, regardless of the manufacturer. Learn more

Save time and stay productive

Want to experience buying made simple?

Agilent Online Store

The Agilent Online Store can help you quickly find what you’re looking for—and take the stress out of ordering. So you can spend more time on what matters.

Shop now and take 20% off your first online purchase using promo code 1390—and 10% off future online orders with promo code 1295.

Learn more

Need to streamline purchasing?

Agilent Flexible Spend Plan

Allocate funds to support your lab with the Agilent Flexible Spend Plan. It enables you to spend money on what you need, when you need it, maintaining optimal instrument performance without jeopardizing your budget.

Get started