To address today’s demands for trace-level analysis and minimal downtime, Agilent ensures optimal GC and GC/MS performance with precision-engineered supplies for both current and legacy systems. This proactive approach allows your team to plan maintenance and focus on producing timely, accurate data.
Our goals are your goals. Agilent is committed to helping you meet your analytical needs efficiently by delivering critical sample reports faster and reducing system maintenance.
The new gold standard
Agilent J&W 5Q GC columns ensure optimal analyte delivery to your quadrupoles, so you can stretch your science to the limit.
Learn more
Managing helium use
Find resources and strategies for managing the price fluctuations and potential delivery interruptions associated with helium carrier gas.
Learn more
GC and GC/MS supplies
Minimize disruptions and maintain optimal instrument performance. Access curated essential instrument supply lists for Agilent GC and GC/MS systems.
Learn more
Agilent J&W GC columns
Put 50 years of quality and innovation behind your GC separations. As you strive to maximize productivity and performance, you can count on Agilent J&W GC columns.
Learn more
Customer insights
SEP China specializes in environmental and consumer product analyses. Find out how they partnered with Agilent for GC instruments, supplies, and columns.
Watch video
Agilent Community
Get answers. Share insights. Build connections. The Agilent Community is your online resource for helping each other succeed.
Learn more
Agilent GC and GC/MS instruments take the guesswork out of troubleshooting, enabling your team to work smarter, not harder. Designed for simplicity and efficiency, these systems reduce training requirements, save valuable lab space, and boost productivity with cutting-edge automation. Our inert, easy-to-use columns and supplies are expertly crafted to seamlessly integrate with Agilent instruments, delivering consistent, reliable results.
With Agilent, you can monitor your lab from anywhere, at any time, thanks to mobile access that puts control in the palm of your hand. Maximize performance with purpose-built supplies and take full advantage of award-winning system intelligence, intuitive diagnostics, and remote monitoring—all accessible through an integrated touchscreen or browser interface. It’s a smarter, more streamlined way to drive productivity and ensure peak performance every day.
Inert flow path
Agilent Inert Flow Path solutions minimize activity along every step of your GC and GC/MS flow path, improving data quality and minimizing unplanned maintenance.
Learn more
Gas Clean filter and sensor
Keep damaging impurities out of your gas line with the Agilent Gas Clean purification system. It prevents moisture and other contaminants from jeopardizing your results.
Learn more
Vials, caps, inserts, and septa
Boost lab productivity and return on investment. Meet your sample containment requirements through our broad range of GC vials, inserts, caps, and septa.
Learn more
GC autosampler syringes
Backed by our commitment to quality, Agilent autosampler syringes and needles help your sample runs proceed flawlessly.
Learn more
Self-tightening column nut
This collared, stainless steel GC column nut delivers a finger tight connection—without expensive upgrades, adaptors, or tools.
Learn more
Water testing standards
Confidently measure and report water contaminant concentrations using Agilent chemical standards.
Learn more
Have you identified and addressed impediments to efficiency in your lab’s day-to-day operations? The more insight you have into increasing throughput, the more you stand to gain financially. Agilent provides the instruments, columns, supplies, and tools that help you increase efficiency, enhance operations, reduce costs, and improve business results.
Partner with Agilent to empower your team to work smarter, deliver timely results, and reduce stress from missed deliverables. Achieve savings with robust consumables that offer long-lasting performance. Maximize profits through shorter cycle times, longer consumable lifetimes, and reduced frequency of unscheduled instrument maintenance.
Flow meter/leak detector
Combine two GC diagnostic tools into one convenient package with the ACT-labeled Agilent CrossLab CS Electronic Leak Detector and ADM Flow Meter cartridge system.
Learn more
Alternative carrier gases
Avoid disruptions caused by helium shortages. Consider an alternative carrier gas option that best suits your analysis.
Learn more
HydroInert source
Optimize GC/MS performance with hydrogen carrier gas. The Agilent HydroInert source improves chromatographic efficiencies when using hydrogen as an alternative to helium.
Learn more
IDP oil-free vacuum pump
Change your pump, not your oil. Agilent IDP-3 and IDP-10 oil-free dry pumps eliminate oil/filter replacements, and promote sustainability by reducing hazardous waste.
Learn more
Detector jets
Newly designed FID and NPD jets install with ease and are universally compatible with packed and capillary columns.
Learn more
8850 GC
When faced with the challenges of increasing sample throughput and bench space limitations for adding analytical capacity, consider the Agilent 8850 GC, a small yet powerful GC, designed to reduce unscheduled maintenance and maximize uptime.
Learn more
As your strategic partner from insight to outcome, Agilent provides a wide array of resources to help your team perform, produce, and profit.
- Agilent-tested workflows for specific applications are built using market-leading columns and supplies.
- Consumables ordering guides list all the part numbers you need for your application—so you don’t have to waste time with catalogs. One-click links let you add items to your Favorite Products list in the Agilent online store, saving you time on future orders.
- All-in-one convenience kits include everything required to implement a GC or GC/MS application, including CDS method parameters.
Alternative energy: Lithium-ion batteries
Regulatory policies and sustainability concerns have increased demand for new battery manufacturing technologies. Make sure your lab stays ahead of the curve.
Learn more
Food safety testing
Perform fast, flexible, and reliable GC/MS/MS analysis of pesticides in high-chlorophyll leafy vegetables using midcolumn backflushing.
Learn more
Alternative energy: Hydrogen analysis
Ensure hydrogen fuel safety and quality with reliable, high-performing, intelligent GC systems and analyzers for impurities analysis.
Learn more
Testing for water contaminants
Ensure fast, accurate, and reliable environmental analysis of water, air, and emerging contaminants with proven GC/MS and regulatory expertise from Agilent.
Learn more
Drug safety and efficacy
Developing small molecules and biologics is complex and costly—demanding up-to-date knowledge, evolving technology, and navigation of scientific and business challenges.
Learn more
Stay connected with the latest product introductions, applications, and how-tos with on-demand webinars from Agilent. These technical one-hour events are a convenient way to learn from industry professionals and keep your knowledge up to date on the latest technologies.
Maximize performance
Learn how to get the best peaks (and performance) by matching your analysis with the right parameters and consumables. Take a deep dive into columns, liners, gain factor, extraction lenses, and more—and find out whether a glass wool liner is right for your analysis.
Watch now
Increase productivity
Discover why an inert flow path is key to optimal performance and consistent, reliable results, particularly for low-trace level analysis. You’ll also learn how supplies like Ultra Inert GC columns, liners, gold seals, and gold-coated ferrules minimize downtime and maximize sensitivity.
Watch now
Maintain sensitivity
Explore the sensitivity of different GC detectors—both mass spectrometer and non-MS. Other topics include optimizing GC supplies and parameters for the best separation and peak shape as your analytes enter the detector.
Watch now
Troubleshoot and improve
Learn how to troubleshoot GC/MS problems and “future-proof” your analysis through the eyes of an Agilent scientist. We also discuss how to use artifacts observed in chromatograms and tune reports to diagnose and fix common problems.
Watch now
Speed up your GC methods
Find out how to properly transition your method from helium to hydrogen carrier gas, including which consumables you may what to change. Presenters also discuss lesser-known options for making your gas last, as well as tips and tricks for speeding up your analysis.
Watch now
Ask the experts
Listen to a panel of Agilent GC and GC/MS scientists answer frequently asked questions about how different carrier gases impact results. The also discuss what to consider when converting methods from one carrier gas to another.
Watch now
An integrated approach to inertness: The Agilent advantage
Ensure the inertness of every surface that touches your sample, so you can achieve the parts-per-billion—or parts-per-trillion—detection levels that today’s analyses demand.
Purifying your gases protects columns and improves analytical performance
Reducing contaminant entry into the GC column prolongs column life and is critical for high-temperature analysis. The Agilent Gas Clean purification system delivers clean gases, reducing the risk of column damage, sensitivity loss, and instrument downtime. A sensor notifies you when it’s time to replace the filter.
See how easy it is to install the Gas Clean purification system on your GC or GC/MS instrument.
Watch video
Choose Agilent-designed sample containment supplies for your GC instruments
Premium certified vials, caps, high-recovery vials, and inserts provide industry-leading performance. Our portfolio includes borosilicate glass and polypropylene vials, crimp cap vials, snap cap vials, screw cap vials, high recovery vials, and vial inserts. Low-bleed septa and inert glass vial materials deliver quality results and help drive productivity.
Posters
Selector tool
Video
We continuously refine the “small” details that make a big difference for our vials, inserts, caps, and septa.
Discover now
Gold standard and blue line syringes for Agilent GC autosamplers
Reduce costly downtime and increase plunger life with economical and high-productivity options.
- Gold standard syringes offer a versatile, economical choice for most general applications.
- Blue line syringes are designed to support the higher-productivity features of Agilent automated liquid samplers.
- Purchase options for both lines of syringes allow your operation to control costs for this essential GC accessory.
Achieve precise, effective sample delivery using Agilent syringes for GC autosamplers.
Discover now
Leak-free connections, made easy
The Agilent self-tightening column nut is especially well suited for oxygen sensitive detectors, such as MS and ECD.
- No retightening equals less wasted time.
- Finger-tight design lets anyone make quality, consistent connections without tools.
- Lower column bleed means longer column life.
- Locking collar keeps column in place during installation to ensure consistent, reproducible results.
Brochure
Poster
Flyer
Videos
Guide
Safeguard our most precious resource with quality water-testing reference materials
Ensure water quality and protect human health. Complete your workflow with chemical standards for PFAS, PAHs, dioxins, VOCs, pesticides, hydrocarbons, heavy metals, and more. All from Agilent—the market leader for environmental analysis solutions.
Put GC troubleshooting in the palm of your hand
The Agilent CrossLab CS Electronic Leak Detector and ADM Flow Meter combines leak detection and flow measurement into one ultimate GC diagnostic tool that delivers:
- Ease of use. Simply change the cartridge to swap between flow meter and leak detector functionalities. Quick-read OLED display helps you identify problems fast.
- High sensitivity. The TCD sensor measures helium, hydrogen, and large nitrogen leaks.
- Reduced costs. Save money by combining two functions into a single bundle.
Discover more
Handle the hassles of the helium shortage
Ongoing helium shortages can cause unpredictability for gas chromatographers. With support from Agilent, carefully consider all your options when choosing a carrier gas for your GC or GC/MS method.
Learn more
Reduce chromatographic challenges when using hydrogen carrier gas
Handle the hassles of the helium shortage. The Agilent HydroInert source allows you to:
- Maximize your return on investment for hydrogen carrier gas.
- Achieve faster, shorter separations.
- Reduce sensitivity loss and spectral anomalies.
- Minimize downtime caused by system maintenance and ion source cleaning.
Learn more
Make a clean break from the hassles of oil vacuum pumps
Agilent IDP-3 and IDP-10 oil-free dry pumps provide affordable, oil-free vacuums, and are qualified for use with current and legacy Agilent GC/MSD systems.
- Deliver better vacuum performance than other pumps of similar size
- Promote eco-friendly resource management
- No risk of oil leakage
- No costs and safety concerns of oil disposal
- Low power requirements
Brochure
Flyer
Videos
Go clean, green, and dry with Agilent IDP-3 and IDP-10 oil-free dry pumps.
Discover now
Single-piece jets simplify installation and minimize the risk of damage
As our industry grows and our instruments advance, Agilent FID and NPD jets have evolved as well.
- Shortened jet tail with a wider opening facilitates column installation.
- Etched rings on jet heads ensure quick, easy identification.
- Single machined piece eliminates neck elongation and thread galling (wearing down due to friction) caused by overtightening, which can distort chromatographic results.
- Universal compatibility makes jets suitable for both packed and capillary columns.
Video
Newly designed FID and NPD jets simplify GC maintenance—eliminating the common hassles of jet replacement.
Keep samples flowing through your lab by working smarter, not harder
While compact in stature, the Agilent 8850 GC delivers comparable performance to the Agilent 8890 GC. Recent updates provide greater flexibility on productivity with advantages like these:
- Interface with the Agilent 5977C GC/MSD, Agilent 7000E TQ/GC and the Agilent 7010D TQ/GC
- Availability of S/SL and multimode inlets (MMI)
- CFT backflush functionality
- Smaller oven for fast and efficient temp ramps
- Built-in diagnostics to facilitate maintenance and troubleshooting diagnostics
Explore
Supply quality products and deliver on time
The development and use of energy storage devices such as lithium-ion and other rechargeable batteries continue to expand. However, inconsistencies in material quality and production processes can lead to performance issues, delays, and increased costs. Partner with Agilent to ensure business success—whether your focus is on R&D, quality control, or EHS compliance.
Discover more
Improve productivity and flexibility for multi-class pesticide analyses
Agilent Capillary Flow Technology (CFT) allows GC and GC/MS operators to make reliable, leak-free capillary connections. Many CFT devices also enable backflush, which can reduce sample preparation and downtime by preventing heavy contaminants from reaching the analytical column and detector.
CFT can be used confidently and reliably in demanding applications like the analysis of trace-level pesticides in spinach. This methodology can also be converted to hydrogen carrier gas by adding a HydroInert source and by adjusting column dimensions.
Detect and quantify trace impurities in hydrogen fuel
Hydrogen gas is emerging as a promising source of clean, renewable, and sustainable fuel. Around the globe, hydrogen-fueled vehicles including cars, buses, and trucks are increasing in popularity.
All hydrogen gas must be tested for impurities using ISO-14687-2 specifications and SAE J 2719, GB/T 3634.2, and GB/T 37244 standard test methods. Agilent provides reliable, high-performing, intelligent GC systems and analyzers for confident impurities analysis.
Discover more
Protecting water quality standards in every analysis
Agilent consumable workflow guides recommend the right products for every step of specific applications—covering standards, sample prep, containment, columns, and more.
Confidently meet regulatory demands and streamline analysis
Agilent consumable workflow guides help ensure accurate, reproducible results while streamlining residual solvents analysis. With strict regulations and the risks posed by trace-level impurities, reliable detection is essential for drug safety and compliance.